-
Performance of a Front End prototype ASIC for picosecond precision time measurements with LGAD sensors
Authors:
C. Agapopoulou,
S. Blin,
A. Blot,
L. Castillo Garcia,
M. Chmeissani,
S. Conforti di Lorenzo,
C. de La Taille,
P. Dinaucourt,
A. Fallou,
J. Garcia Rodriguez,
V. Gkougkousis,
C. Grieco,
S. Grinstein,
S. Guindon,
N. Makovec,
G. Martin-Chassard,
G. Pellegrini,
A. Rummler,
S. Sacerdoti,
N. Seguin Moreau,
L. Serin,
A. Tricoli
Abstract:
For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must maintain the perfo…
▽ More
For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must maintain the performance of the sensor, while keeping low power consumption. This paper presents the results on the first prototype of a front-end ASIC, named ALTIROC0, which contains the analog stages (preamplifier and discriminator) of the read-out chip. The ASIC was characterised both alone and as part of a module with a 2$\times$2 LGAD array of 1.1$\times$1.1 mm$^2$ pads bump-bonded to it. The various contributions of the electronics to the time resolution were investigated in test-bench measurements with a calibration setup. Both when the ASIC is alone or with a bump-bonded sensor, the jitter of the ASIC is better than 20 ps for an injected charge of 10 fC. The time walk effect that arises from the different response of the preamplifier for various injected charges can be corrected up to 10 ps using a Time Over Threshold measurement. The combined performance of the ASIC and the LGAD sensor, which was measured during a beam test campaign in October 2018 with pions of 120 GeV energy at the CERN SPS, is around 40 ps for all measured modules. All tested modules show good efficiency and time resolution uniformity.
△ Less
Submitted 7 July, 2020; v1 submitted 14 February, 2020;
originally announced February 2020.
-
Performance of Irradiated RD53A 3D Pixel Sensors
Authors:
S. Terzo,
M. Chmeissani,
G. Giannini,
S. Grinstein,
M. Manna,
G. Pellegrini,
D. Quirion,
D. Vazquez Furelos
Abstract:
The ATLAS experiment at the LHC will replace its current inner tracker system for the HL-LHC era. 3D silicon pixel sensors are being considered as radiation-hard candidates for the innermost layers of the new fully silicon-based tracking detector. 3D sensors with a small pixel size of $\mathrm{50 \times 50~μm^{2}}$ and $\mathrm{25 \times 100~μm^{2}}$ compatible with the first prototype ASIC for th…
▽ More
The ATLAS experiment at the LHC will replace its current inner tracker system for the HL-LHC era. 3D silicon pixel sensors are being considered as radiation-hard candidates for the innermost layers of the new fully silicon-based tracking detector. 3D sensors with a small pixel size of $\mathrm{50 \times 50~μm^{2}}$ and $\mathrm{25 \times 100~μm^{2}}$ compatible with the first prototype ASIC for the HL-LHC, the RD53A chip, have been studied in beam tests after uniform irradiation to $\mathrm{5 \times 10^{15}~n_{eq}/cm^{2}}$. An operation voltage of only 50 V is needed to achieve a 97% hit efficiency after this fluence.
△ Less
Submitted 22 March, 2019; v1 submitted 12 March, 2019;
originally announced March 2019.
-
Module production of the one-arm AFP 3D pixel tracker
Authors:
S. Grinstein,
E. Cavallaro,
M. Chmeissani,
O. Dorholt,
F. Foerster,
J. Lange,
I. Lopez Paz,
M. Manna,
G. Pellegrini,
D. Quirion,
M. Rijssenbeek,
O. Rohne,
B. Stugu
Abstract:
The ATLAS Forward Proton (AFP) detector is designed to identify events in which one or two protons emerge intact from the LHC collisions. AFP will consist of a tracking detector, to measure the momentum of the protons, and a time of flight system to reduce the background from multiple proton-proton interactions. Following an extensive qualification period, 3D silicon pixel sensors were selected fo…
▽ More
The ATLAS Forward Proton (AFP) detector is designed to identify events in which one or two protons emerge intact from the LHC collisions. AFP will consist of a tracking detector, to measure the momentum of the protons, and a time of flight system to reduce the background from multiple proton-proton interactions. Following an extensive qualification period, 3D silicon pixel sensors were selected for the AFP tracker. The sensors were produced at CNM (Barcelona) during 2014. The tracker module assembly and quality control was performed at IFAE during 2015. The assembly of the first AFP arm and the following installation in the LHC tunnel took place in February 2016. This paper reviews the fabrication process of the AFP tracker focusing on the pixel modules.
△ Less
Submitted 19 December, 2016; v1 submitted 3 November, 2016;
originally announced November 2016.
-
From laboratory experiments to LISA Pathfinder: achieving LISA geodesic motion
Authors:
F Antonucci,
M Armano,
H Audley,
G Auger,
M Benedetti,
P Binetruy,
C Boatella,
J Bogenstahl,
D Bortoluzzi,
P Bosetti,
N Brandt,
M Caleno,
A Cavalleri,
M Cesa,
M Chmeissani,
G Ciani,
A Conchillo,
G Congedo,
I Cristofolini,
M Cruise,
K Danzmann,
F De Marchi,
M Diaz-Aguilo,
I Diepholz,
G Dixon
, et al. (76 additional authors not shown)
Abstract:
This paper presents a quantitative assessment of the performance of the upcoming LISA Pathfinder geodesic explorer mission. The findings are based on the results of extensive ground testing and simulation campaigns using flight hardware and flight control and operations algorithms. The results show that, for the central experiment of measuring the stray differential acceleration between the LISA t…
▽ More
This paper presents a quantitative assessment of the performance of the upcoming LISA Pathfinder geodesic explorer mission. The findings are based on the results of extensive ground testing and simulation campaigns using flight hardware and flight control and operations algorithms. The results show that, for the central experiment of measuring the stray differential acceleration between the LISA test masses, LISA Pathfinder will be able to verify the overall acceleration noise to within a factor two of the LISA requirement at 1 mHz and within a factor 6 at 0.1 mHz. We also discuss the key elements of the physical model of disturbances, coming from LISA Pathfinder and ground measurement, that will guarantee the LISA performance.
△ Less
Submitted 20 January, 2011; v1 submitted 29 December, 2010;
originally announced December 2010.
-
Search for neutral Higgs bosons decaying into four taus at LEP2
Authors:
ALEPH Collaboration,
S. Schael,
R. Barate,
R. Brunelière,
I. De Bonis,
D. Decamp,
C. Goy,
S. Jézéquel,
J. -P. Lees,
F. Martin,
E. Merle,
M. -N. Minard,
B. Pietrzyk,
B. Trocmé S. Bravo,
M. P. Casado,
M. Chmeissani,
J. M. Crespo,
E. Fernandez,
M. Fernandez-Bosman,
Ll. Garrido,
M. Martinez,
A. Pacheco,
H. Ruiz,
A. Colaleo,
D. Creanza
, et al. (236 additional authors not shown)
Abstract:
A search for the production and non-standard decay of a Higgs boson, h, into four taus through intermediate pseudoscalars, a, is conducted on 683 pb-1 of data collected by the ALEPH experiment at centre-of-mass energies from 183 to 209 GeV. No excess of events above background is observed, and exclusion limits are placed on the combined production cross section times branching ratio, ξ^2 = σ(e+e…
▽ More
A search for the production and non-standard decay of a Higgs boson, h, into four taus through intermediate pseudoscalars, a, is conducted on 683 pb-1 of data collected by the ALEPH experiment at centre-of-mass energies from 183 to 209 GeV. No excess of events above background is observed, and exclusion limits are placed on the combined production cross section times branching ratio, ξ^2 = σ(e+e- --> Zh)/σ_{SM}(e+e- --> Zh) x B(h --> aa)x B(a --> τ^+τ^-)^2. For mh < 107 GeV/c2 and 4 < ma < 10 GeV/c2, ξ^2 > 1 is excluded at the 95% confidence level.
△ Less
Submitted 19 April, 2010; v1 submitted 2 March, 2010;
originally announced March 2010.
-
In-flight Diagnostics in LISA Pathfinder
Authors:
Alberto Lobo,
Miquel Nofrarias,
Juan Ramos-Castro,
Josep Sanjuan,
Aleix Conchillo,
Jose Antonio Ortega,
Xevi Xirgu,
Henrique Araujo,
Cesar Boatella,
Mokhtar Chmeissani,
Catia Grimani,
Carles Puigdengoles,
Peter Wass,
Enrique Garcia-Berro,
Sergi Garcia,
Lluis Martinez,
Gustau Montero
Abstract:
LISA PathFinder (LPF) will be flown with the objective to test in space key technologies for LISA. However its sensitivity goals are, for good reason, one order of magnitude less than those which LISA will have to meet, both in drag-free and optical metrology requirements, and in the observation frequency band. While the expected success of LPF will of course be of itself a major step forward to…
▽ More
LISA PathFinder (LPF) will be flown with the objective to test in space key technologies for LISA. However its sensitivity goals are, for good reason, one order of magnitude less than those which LISA will have to meet, both in drag-free and optical metrology requirements, and in the observation frequency band. While the expected success of LPF will of course be of itself a major step forward to LISA, one might not forget that a further improvement by an order of magnitude in performance will still be needed. Clues for the last leap are to be derived from proper disentanglement of the various sources of noise which contribute to the total noise, as measured in flight during the PathFinder mission. This paper describes the principles, workings and requirements of one of the key tools to serve the above objective: the diagnostics subsystem. This consists in sets of temperature, magnetic field, and particle counter sensors, together with generators of controlled thermal and magnetic perturbations. At least during the commissioning phase, the latter will be used to identify feed-through coefficients between diagnostics sensor readings and associated actual noise contributions. A brief progress report of the current state of development of the diagnostics subsystem will be given as well.
△ Less
Submitted 23 December, 2006;
originally announced December 2006.
-
LISA and LISA PathFinder, the endeavour to detect low frequency GWs
Authors:
Henrique Araujo,
Cesar Boatella,
Mokhtar Chmeissani,
Aleix Conchillo,
Enrique Garcia-Berro,
Catia Grimani,
Wojtek Hajdas,
Alberto Lobo,
Lluis Martinez,
Miquel Nofrarias,
Jose Antonio Ortega,
Carles Puigdengoles,
Juan Ramos-Castro,
Josep Sanjuan,
Peter Wass,
Xevi Xirgu
Abstract:
This is a review about LISA and its technology demonstrator, LISA PathFinder. We first describe the conceptual problems which need to be overcome in order to set up a working interferometric detector of low frequency Gravitational Waves (GW), then summarise the solutions to them as currently conceived by the LISA mission team. This will show that some of these solutions require new technological…
▽ More
This is a review about LISA and its technology demonstrator, LISA PathFinder. We first describe the conceptual problems which need to be overcome in order to set up a working interferometric detector of low frequency Gravitational Waves (GW), then summarise the solutions to them as currently conceived by the LISA mission team. This will show that some of these solutions require new technological abilities which are still under development, and which need proper test before being fully implemented. LISA PathFinder (LPF) is the the testbed for such technologies. The final part of the paper will address the ideas and concepts behind the PathFinder as well as their impact on LISA.
△ Less
Submitted 23 December, 2006;
originally announced December 2006.