-
Water exchange and microscopic kurtosis -- two sides of the same coin?
Authors:
Arthur Chakwizira,
Filip Szczepankiewicz,
Markus Nilsson
Abstract:
Diffusion MRI is sensitive to a wide range of features of the microstructure including diffusivity, exchange and three sources of diffusional kurtosis: isotropic, anisotropic, and microscopic. Correlation tensor imaging (CTI) uses double diffusion encoding (DDE) to resolve all three kurtosis components. In that framework, microscopic kurtosis is estimated from the contrast between SDE and parallel…
▽ More
Diffusion MRI is sensitive to a wide range of features of the microstructure including diffusivity, exchange and three sources of diffusional kurtosis: isotropic, anisotropic, and microscopic. Correlation tensor imaging (CTI) uses double diffusion encoding (DDE) to resolve all three kurtosis components. In that framework, microscopic kurtosis is estimated from the contrast between SDE and parallel DDE signals at the same b-value. Another approach is multi-Gaussian exchange (MGE), which can apply DDE to measure exchange. The highest exchange sensitivity in MGE is obtained by contrasting SDE and DDE signals at the same b-value. CTI and MGE can thus be applied to analyse the same data, but exchange can bias microscopic kurtosis estimates if not accounted for, and vice versa. Here, we develop new theory (MGE incorporating microscopic kurtosis, $μ$MGE) that accounts for both effects, by exploiting the distinct signatures of exchange and microscopic kurtosis with varying mixing time: exchange causes a dependence of the signal on mixing time while microscopic kurtosis does not. We perform Monte-Carlo simulations in different geometries with varying levels of exchange and study the behaviour of the parameters from CTI, MGE, and $μ$MGE. We conclude that microscopic kurtosis from CTI is positively biased by exchange. We also find that applying $μ$MGE to data acquired with multiple mixing times for both parallel and orthogonal DDE allows accurate estimation of exchange and all three sources of kurtosis.
△ Less
Submitted 25 March, 2024; v1 submitted 6 June, 2023;
originally announced June 2023.
-
Diffusion MRI with free gradient waveforms on a high-performance gradient system: Probing restriction and exchange in the human brain
Authors:
Arthur Chakwizira,
Ante Zhu,
Thomas Foo,
Carl-Fredrik Westin,
Filip Szczepankiewicz,
Markus Nilsson
Abstract:
The dependence of the diffusion MRI signal on the diffusion time carries signatures of restricted diffusion and exchange. Here we seek to highlight these signatures in the human brain by performing experiments using free gradient waveforms that are selectively sensitive to the two effects. We examine six healthy volunteers using both strong and ultra-strong gradients (80, 200 and 300 mT/m). In an…
▽ More
The dependence of the diffusion MRI signal on the diffusion time carries signatures of restricted diffusion and exchange. Here we seek to highlight these signatures in the human brain by performing experiments using free gradient waveforms that are selectively sensitive to the two effects. We examine six healthy volunteers using both strong and ultra-strong gradients (80, 200 and 300 mT/m). In an experiment featuring a large set of gradient waveforms with different sensitivities to restricted diffusion and exchange (150 samples), our results reveal unique time-dependence signatures in grey and white matter, where the former is characterised by both restricted diffusion and exchange and the latter predominantly exhibits restricted diffusion. Furthermore, we show that gradient waveforms with independently varying sensitivities to restricted diffusion and exchange can be used to map exchange in the human brain. We consistently find that exchange in grey matter is at least twice as fast as in white matter, across all subjects and all gradient strengths. The shortest exchange times observed in this study were in the cerebellar cortex (115 ms). We also assess the feasibility of future clinical applications of the method used in this work, where we find that the grey-white matter exchange contrast obtained with a 25-minute 300 mT/m protocol is preserved by a 4-minute 300 mT/m and a 10-minute 80 mT/m protocol. Our work underlines the utility of free waveforms for detecting time-dependence signatures due to restricted diffusion and exchange in vivo, which may potentially serve as a tool for studying diseased tissue.
△ Less
Submitted 5 April, 2023;
originally announced April 2023.
-
Probing restricted diffusion and exchange using free gradient waveforms: validation by numerical simulations
Authors:
Arthur Chakwizira,
Carl-Fredrik Westin,
Jan Brabec,
Samo Lasič,
Linda Knutsson,
Filip Szczepankiewicz,
Markus Nilsson
Abstract:
Monitoring time-dependence with diffusion MRI yields observables sensitive to compartment sizes (restricted diffusion) and membrane permeability (water exchange). However, restricted diffusion and exchange have opposite effects on the diffusion-weighted signal, which can confound parameter estimates. In this work, we present a signal representation that captures the effects of both restricted diff…
▽ More
Monitoring time-dependence with diffusion MRI yields observables sensitive to compartment sizes (restricted diffusion) and membrane permeability (water exchange). However, restricted diffusion and exchange have opposite effects on the diffusion-weighted signal, which can confound parameter estimates. In this work, we present a signal representation that captures the effects of both restricted diffusion and exchange up to second order in b-value and is compatible with gradient waveforms of arbitrary shape. The representation features mappings from a gradient waveform to two scalars that separately control the sensitivity to restriction and exchange. We demonstrate that these scalars span a two-dimensional space that can be used to choose waveforms that selectively probe restricted diffusion or exchange, in order to eliminate the correlation between the two phenomena. We found that waveforms with specific but unconventional shapes provide an advantage over conventional pulsed and oscillating gradient acquisitions. We also show that parametrisation of waveforms into a two-dimensional space can be used to understand protocols from other approaches that probe restricted diffusion and exchange. For example, we find that the variation of mixing time in filter-exchange imaging corresponds to variation of our exchange-weighting scalar at a fixed value of the restriction-weighting scalar. Numerical evaluation of the proposed signal representation using Monte Carlo simulations on a synthetic substrate showed that the theory is applicable to sizes in the range 2 - 7 micrometres and barrier-limited exchange in the range 0 - 20 s$^{-1}$. The presented theory constitutes a simple and intuitive description of how restricted diffusion and exchange influence the signal as well as how to design a protocol to separate the two effects.
△ Less
Submitted 22 November, 2021;
originally announced November 2021.