-
First search for dark photon dark matter with a MADMAX prototype
Authors:
J. Egge,
D. Leppla-Weber,
S. Knirck,
B. Ary dos Santos Garcia,
D. Bergermann,
A. Caldwell,
V. Dabhi,
C. Diaconu,
J. Diehl,
G. Dvali,
M. Ekmedžić,
F. Gallo,
E. Garutti,
S. Heyminck,
F. Hubaut,
A. Ivanov,
J. Jochum,
P. Karst,
M. Kramer,
D. Kreikemeyer-Lorenzo,
C. Krieger,
C. Lee,
A. Lindner,
J. P. A. Maldonado,
B. Majorovits
, et al. (21 additional authors not shown)
Abstract:
We report the first result from a dark photon dark matter search in the mass range from ${78.62}$ to $83.95~\mathrm{μeV}/c^2$ with a dielectric haloscope prototype for MADMAX (Magnetized Disc and Mirror Axion eXperiment). Putative dark photons would convert to observable photons within a stack consisting of three sapphire disks and a mirror. The emitted power of this system is received by an anten…
▽ More
We report the first result from a dark photon dark matter search in the mass range from ${78.62}$ to $83.95~\mathrm{μeV}/c^2$ with a dielectric haloscope prototype for MADMAX (Magnetized Disc and Mirror Axion eXperiment). Putative dark photons would convert to observable photons within a stack consisting of three sapphire disks and a mirror. The emitted power of this system is received by an antenna and successively digitized using a low-noise receiver. No dark photon signal has been observed. Assuming unpolarized dark photon dark matter with a local density of $ρ_χ=0.3~\mathrm{GeV/cm^3}$ we exclude a dark photon to photon mixing parameter $χ> 3.0 \times 10^{-12}$ over the full mass range and $χ> 1.2 \times 10^{-13}$ at a mass of $80.57~\mathrm{μeV}/c^2$ with a 95\% confidence level. This is the first physics result from a MADMAX prototype and exceeds previous constraints on $χ$ in this mass range by up to almost three orders of magnitude.
△ Less
Submitted 5 August, 2024;
originally announced August 2024.
-
Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS
Authors:
Edgar Marrufo Villalpando,
Alex Drlica-Wagner,
Brandon Roach,
Marco Bonati,
Abhishek Bakshi,
Julia Campa,
Gustavo Cancelo,
Braulio Cancino,
Claudio R. Chavez,
Fernando Chierchie,
Juan Estrada,
Guillermo Fernandez Moroni,
Luciano Fraga,
Manuel E. Gaido,
Stephen E. Holland,
Rachel Hur,
Michelle Jonas,
Peter Moore,
Eduardo Paolini,
Andrés A. Plazas Malagón,
Leandro Stefanazzi,
Javier Tiffenberg,
Ken Treptou,
Sho Uemura,
Neal Wilcer
Abstract:
We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k x 1k, 15 $μ$m pixel, fully-depleted, p-channel devices that have been thinned to ~250 $μ$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astro…
▽ More
We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k x 1k, 15 $μ$m pixel, fully-depleted, p-channel devices that have been thinned to ~250 $μ$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., single-sample readout noise < 4.3 e- rms/pixel, the ability to achieve multi-sample readout noise $\ll$ 1 e- rms/pixel, full-well capacities ~40,000-65,000 e-, low dark current and charge transfer inefficiency (~2 x 10$^{-4}$ e-/pixel/s and 3.44 x 10$^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim$ 80% between 450 nm and 980 nm ($\gtrsim$ 90% between 600 nm and 900 nm). We optimized the readout sequence timing to achieve sub-electron noise (~0.5 e- rms/pixel) in a region of 2k x 4k pixels and photon-counting noise (~0.22 e- rms/pixel) in a region of 220 x 4k pixels, each with a readout time of $\lesssim$ 17 min. We observed two quasars (HB89 1159+123 and QSO J1621-0042) at redshift z ~ 3.5, two high-redshift galaxy clusters (CL J1001+0220 and SPT-CL J2040-4451), an emission line galaxy at z = 0.3239, a candidate member star of the Boötes II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observations of the quasar HB89 1159+123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvements for SIFS observations in the low-background, readout-noise-dominated regime. We outline scientific studies that will leverage the SIFS-Skipper CCD data and new detector architectures that utilize the Skipper floating gate amplifier with faster readout times.
△ Less
Submitted 15 June, 2024;
originally announced June 2024.
-
Search for reactor-produced millicharged particles with Skipper-CCDs at the CONNIE and Atucha-II experiments
Authors:
Alexis A. Aguilar-Arevalo,
Nicolas Avalos,
Pablo Bellino,
Xavier Bertou,
Carla Bonifazi,
Ana Botti,
Mariano Cababié,
Gustavo Cancelo,
Brenda A. Cervantes-Vergara,
Claudio Chavez,
Fernando Chierchie,
David Delgado,
Eliana Depaoli,
Juan Carlos D'Olivo,
João dos Anjos,
Juan Estrada,
Guillermo Fernandez Moroni,
Aldo R. Fernandes Neto,
Richard Ford,
Ben Kilminster,
Kevin Kuk,
Andrew Lathrop,
Patrick Lemos,
Herman P. Lima Jr.,
Martin Makler
, et al. (15 additional authors not shown)
Abstract:
Millicharged particles, proposed by various extensions of the standard model, can be created in pairs by high-energy photons within nuclear reactors and can interact electromagnetically with electrons in matter. Recently, the existence of a plasmon peak in the interaction cross-section with silicon in the eV range was highlighted as a promising approach to enhance low-energy sensitivities. The CON…
▽ More
Millicharged particles, proposed by various extensions of the standard model, can be created in pairs by high-energy photons within nuclear reactors and can interact electromagnetically with electrons in matter. Recently, the existence of a plasmon peak in the interaction cross-section with silicon in the eV range was highlighted as a promising approach to enhance low-energy sensitivities. The CONNIE and Atucha-II reactor neutrino experiments utilize Skipper-CCD sensors, which enable the detection of interactions in the eV range. We present world-leading limits on the charge of millicharged particles within a mass range spanning six orders of magnitude, derived through a comprehensive analysis and the combination of data from both experiments.
△ Less
Submitted 25 May, 2024;
originally announced May 2024.
-
First Measurement of Correlated Charge Noise in Superconducting Qubits at an Underground Facility
Authors:
G. Bratrud,
S. Lewis,
K. Anyang,
A. Colón Cesaní,
T. Dyson,
H. Magoon,
D. Sabhari,
G. Spahn,
G. Wagner,
R. Gualtieri,
N. A. Kurinsky,
R. Linehan,
R. McDermott,
S. Sussman,
D. J. Temples,
S. Uemura,
C. Bathurst,
G. Cancelo,
R. Chen,
A. Chou,
I. Hernandez,
M. Hollister,
L. Hsu,
C. James,
K. Kennard
, et al. (13 additional authors not shown)
Abstract:
We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth's surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4$π$ coverage of a movable lead s…
▽ More
We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth's surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4$π$ coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of 0.19$^{+0.04}_{-0.03}$ mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly eight higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.
△ Less
Submitted 27 June, 2024; v1 submitted 7 May, 2024;
originally announced May 2024.
-
Cryogenic optical beam steering for superconducting device calibration
Authors:
K. Stifter,
H. Magoon,
A. J. Anderson,
D. J. Temples,
N. A. Kurinsky,
C. Stoughton,
I. Hernandez,
A. Nuñez,
K. Anyang,
R. Linehan,
M. R. Young,
P. Barry,
D. Baxter,
D. Bowring,
G. Cancelo,
A. Chou,
K. R. Dibert,
E. Figueroa-Feliciano,
L. Hsu,
R. Khatiwada,
S. D. Mork,
L. Stefanazzi,
N. Tabassum,
S. Uemura,
B. A. Young
Abstract:
We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $μ$m, enabling charac…
▽ More
We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $μ$m, enabling characterization of device response as a function of position. This fills a critical need in the landscape of calibration tools for sub-Kelvin devices, including those used for dark matter detection and quantum computing. These communities have a shared goal of understanding the impact of ionizing radiation on device performance, which can be pursued with our system. This paper describes the design of the first-generation calibration system and the results from successfully testing its performance at room temperature and 20 mK.
△ Less
Submitted 3 May, 2024;
originally announced May 2024.
-
Estimating the Energy Threshold of Phonon-mediated Superconducting Qubit Detectors Operated in an Energy-Relaxation Sensing Scheme
Authors:
R. Linehan,
I. Hernandez,
D. J. Temples,
S. Q. Dang,
D. Baxter,
L. Hsu,
E. Figueroa-Feliciano,
R. Khatiwada,
K. Anyang,
D. Bowring,
G. Bratrud,
G. Cancelo,
A. Chou,
R. Gualtieri,
K. Stifter,
S. Sussman
Abstract:
In recent years, the lack of a conclusive detection of WIMP dark matter at the 10 GeV/c$^{2}$ mass scale and above has encouraged development of low-threshold detector technology aimed at probing lighter dark matter candidates. Detectors based on Cooper-pair-breaking sensors have emerged as a promising avenue for this detection due to the low (meV-scale) energy required for breaking a Cooper pair…
▽ More
In recent years, the lack of a conclusive detection of WIMP dark matter at the 10 GeV/c$^{2}$ mass scale and above has encouraged development of low-threshold detector technology aimed at probing lighter dark matter candidates. Detectors based on Cooper-pair-breaking sensors have emerged as a promising avenue for this detection due to the low (meV-scale) energy required for breaking a Cooper pair in most superconductors. Among them, devices based on superconducting qubits are interesting candidates for sensing due to their observed sensitivity to broken Cooper pairs. We have developed an end-to-end G4CMP-based simulation framework and have used it to evaluate performance metrics of qubit-based devices operating in a gate-based "energy relaxation" readout scheme, akin to those used in recent studies of qubit sensitivity to ionizing radiation. We find that for this readout scheme, the qubit acts as a phonon sensor with an energy threshold ranging down to $\simeq$0.4 eV for near-term performance parameters.
△ Less
Submitted 5 April, 2024;
originally announced April 2024.
-
Searches for CEνNS and Physics beyond the Standard Model using Skipper-CCDs at CONNIE
Authors:
Alexis A. Aguilar-Arevalo,
Nicolas Avalos,
Xavier Bertou,
Carla Bonifazi,
Gustavo Cancelo,
Brenda A. Cervantes-Vergara,
Claudio Chavez,
Fernando Chierchie,
Gustavo Coelho Corrêa,
Juan Carlos D'Olivo,
João dos Anjos,
Juan Estrada,
Guillermo Fernandez Moroni,
Aldo R. Fernandes Neto,
Richard Ford,
Ben Kilminster,
Kevin Kuk,
Andrew Lathrop,
Patrick Lemos,
Herman P. Lima Jr.,
Martin Makler,
Katherine Maslova,
Franciole Marinho,
Jorge Molina,
Irina Nasteva
, et al. (9 additional authors not shown)
Abstract:
The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) aims to detect the coherent scattering (CE$ν$NS) of reactor antineutrinos off silicon nuclei using thick fully-depleted high-resistivity silicon CCDs. Two Skipper-CCD sensors with sub-electron readout noise capability were installed at the experiment next to the Angra-2 reactor in 2021, making CONNIE the first experiment to employ Skipp…
▽ More
The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) aims to detect the coherent scattering (CE$ν$NS) of reactor antineutrinos off silicon nuclei using thick fully-depleted high-resistivity silicon CCDs. Two Skipper-CCD sensors with sub-electron readout noise capability were installed at the experiment next to the Angra-2 reactor in 2021, making CONNIE the first experiment to employ Skipper-CCDs for reactor neutrino detection. We report on the performance of the Skipper-CCDs, the new data processing and data quality selection techniques and the event selection for CE$ν$NS interactions, which enable CONNIE to reach a record low detection threshold of 15 eV. The data were collected over 300 days in 2021-2022 and correspond to exposures of 14.9 g-days with the reactor-on and 3.5 g-days with the reactor-off. The difference between the reactor-on and off event rates shows no excess and yields upper limits at 95% confidence level for the neutrino interaction rates comparable with previous CONNIE limits from standard CCDs and higher exposures. Searches for new neutrino interactions beyond the Standard Model were performed, yielding an improvement on the previous CONNIE limit on a simplified model with light vector mediators. A first dark matter (DM) search by diurnal modulation was performed by CONNIE and the results represent the best limits on the DM-electron scattering cross-section, obtained by a surface-level experiment. These promising results, obtained using a very small-mass sensor, illustrate the potential of Skipper-CCDs to probe rare neutrino interactions and motivate the plans to increase the detector mass in the near future.
△ Less
Submitted 23 March, 2024;
originally announced March 2024.
-
SENSEI: First Direct-Detection Results on sub-GeV Dark Matter from SENSEI at SNOLAB
Authors:
SENSEI Collaboration,
Prakruth Adari,
Itay M. Bloch,
Ana M. Botti,
Mariano Cababie,
Gustavo Cancelo,
Brenda A. Cervantes-Vergara,
Michael Crisler,
Miguel Daal,
Ansh Desai,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Erez Etzion,
Guillermo Fernandez Moroni,
Stephen E. Holland,
Yonatan Kehat,
Yaron Korn,
Ian Lawson,
Steffon Luoma,
Aviv Orly,
Santiago E. Perez,
Dario Rodrigues,
Nathan A. Saffold,
Silvia Scorza
, et al. (12 additional authors not shown)
Abstract:
We present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. With an exposure of 534.9 gram-days from well-performing sensors, we select events containing 2 to 10 electron-hole pairs. After aggressively masking images to remove backgrounds, we observe 55 two-electron events, 4 three-electron events, and no events containing 4 to 10 elect…
▽ More
We present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. With an exposure of 534.9 gram-days from well-performing sensors, we select events containing 2 to 10 electron-hole pairs. After aggressively masking images to remove backgrounds, we observe 55 two-electron events, 4 three-electron events, and no events containing 4 to 10 electrons. The two-electron events are consistent with pileup from one-electron events. Among the 4 three-electron events, 2 appear in pixels that are likely impacted by detector defects, although not strongly enough to trigger our "hot-pixel" mask. We use these data to set world-leading constraints on sub-GeV dark matter interacting with electrons and nuclei.
△ Less
Submitted 20 December, 2023;
originally announced December 2023.
-
Experimental advances with the QICK (Quantum Instrumentation Control Kit) for superconducting quantum hardware
Authors:
Chunyang Ding,
Martin Di Federico,
Michael Hatridge,
Andrew Houck,
Sebastien Leger,
Jeronimo Martinez,
Connie Miao,
David I. Schuster,
Leandro Stefanazzi,
Chris Stoughton,
Sara Sussman,
Ken Treptow,
Sho Uemura,
Neal Wilcer,
Helin Zhang,
Chao Zhou,
Gustavo Cancelo
Abstract:
The QICK is a standalone open source qubit controller that was first introduced in 2022. In this follow-up work, we present recent experimental use cases that the QICK uniquely enabled for superconducting qubit systems. These include multiplexed signal generation and readout, mixer-free readout, pre-distorted fast flux pulses, and phase-coherent pulses for parametric operations, including high-fid…
▽ More
The QICK is a standalone open source qubit controller that was first introduced in 2022. In this follow-up work, we present recent experimental use cases that the QICK uniquely enabled for superconducting qubit systems. These include multiplexed signal generation and readout, mixer-free readout, pre-distorted fast flux pulses, and phase-coherent pulses for parametric operations, including high-fidelity parametric entangling gates. We explain in detail how the QICK was used to enable these experiments.
△ Less
Submitted 28 November, 2023;
originally announced November 2023.
-
Quantum Sensors for High Energy Physics
Authors:
Aaron Chou,
Kent Irwin,
Reina H. Maruyama,
Oliver K. Baker,
Chelsea Bartram,
Karl K. Berggren,
Gustavo Cancelo,
Daniel Carney,
Clarence L. Chang,
Hsiao-Mei Cho,
Maurice Garcia-Sciveres,
Peter W. Graham,
Salman Habib,
Roni Harnik,
J. G. E. Harris,
Scott A. Hertel,
David B. Hume,
Rakshya Khatiwada,
Timothy L. Kovachy,
Noah Kurinsky,
Steve K. Lamoreaux,
Konrad W. Lehnert,
David R. Leibrandt,
Dale Li,
Ben Loer
, et al. (17 additional authors not shown)
Abstract:
Strong motivation for investing in quantum sensing arises from the need to investigate phenomena that are very weakly coupled to the matter and fields well described by the Standard Model. These can be related to the problems of dark matter, dark sectors not necessarily related to dark matter (for example sterile neutrinos), dark energy and gravity, fundamental constants, and problems with the Sta…
▽ More
Strong motivation for investing in quantum sensing arises from the need to investigate phenomena that are very weakly coupled to the matter and fields well described by the Standard Model. These can be related to the problems of dark matter, dark sectors not necessarily related to dark matter (for example sterile neutrinos), dark energy and gravity, fundamental constants, and problems with the Standard Model itself including the Strong CP problem in QCD. Resulting experimental needs typically involve the measurement of very low energy impulses or low power periodic signals that are normally buried under large backgrounds. This report documents the findings of the 2023 Quantum Sensors for High Energy Physics workshop which identified enabling quantum information science technologies that could be utilized in future particle physics experiments, targeting high energy physics science goals.
△ Less
Submitted 3 November, 2023;
originally announced November 2023.
-
First Results from a Broadband Search for Dark Photon Dark Matter in the $44$ to $52\,μ$eV range with a coaxial dish antenna
Authors:
Stefan Knirck,
Gabe Hoshino,
Mohamed H. Awida,
Gustavo I. Cancelo,
Martin Di Federico,
Benjamin Knepper,
Alex Lapuente,
Mira Littmann,
David W. Miller,
Donald V. Mitchell,
Derrick Rodriguez,
Mark K. Ruschman,
Matthew A. Sawtell,
Leandro Stefanazzi,
Andrew Sonnenschein,
Gary W. Teafoe,
Daniel Bowring,
G. Carosi,
Aaron Chou,
Clarence L. Chang,
Kristin Dona,
Rakshya Khatiwada,
Noah A. Kurinsky,
Jesse Liu,
Cristián Pena
, et al. (3 additional authors not shown)
Abstract:
We present first results from a dark photon dark matter search in the mass range from 44 to 52 $μ{\rm eV}$ ($10.7 - 12.5\,{\rm GHz}$) using a room-temperature dish antenna setup called GigaBREAD. Dark photon dark matter converts to ordinary photons on a cylindrical metallic emission surface with area $0.5\,{\rm m}^2$ and is focused by a novel parabolic reflector onto a horn antenna. Signals are re…
▽ More
We present first results from a dark photon dark matter search in the mass range from 44 to 52 $μ{\rm eV}$ ($10.7 - 12.5\,{\rm GHz}$) using a room-temperature dish antenna setup called GigaBREAD. Dark photon dark matter converts to ordinary photons on a cylindrical metallic emission surface with area $0.5\,{\rm m}^2$ and is focused by a novel parabolic reflector onto a horn antenna. Signals are read out with a low-noise receiver system. A first data taking run with 24 days of data does not show evidence for dark photon dark matter in this mass range, excluding dark photon - photon mixing parameters $χ\gtrsim 10^{-12}$ in this range at 90% confidence level. This surpasses existing constraints by about two orders of magnitude and is the most stringent bound on dark photons in this range below 49 $μ$eV.
△ Less
Submitted 3 May, 2024; v1 submitted 20 October, 2023;
originally announced October 2023.
-
Open Hardware Solutions in Quantum Technology
Authors:
Nathan Shammah,
Anurag Saha Roy,
Carmen G. Almudever,
Sébastien Bourdeauducq,
Anastasiia Butko,
Gustavo Cancelo,
Susan M. Clark,
Johannes Heinsoo,
Loïc Henriet,
Gang Huang,
Christophe Jurczak,
Janne Kotilahti,
Alessandro Landra,
Ryan LaRose,
Andrea Mari,
Kasra Nowrouzi,
Caspar Ockeloen-Korppi,
Guen Prawiroatmodjo,
Irfan Siddiqi,
William J. Zeng
Abstract:
Quantum technologies such as communications, computing, and sensing offer vast opportunities for advanced research and development. While an open-source ethos currently exists within some quantum technologies, especially in quantum computer programming, we argue that there are additional advantages in developing open quantum hardware (OQH). Open quantum hardware encompasses open-source software fo…
▽ More
Quantum technologies such as communications, computing, and sensing offer vast opportunities for advanced research and development. While an open-source ethos currently exists within some quantum technologies, especially in quantum computer programming, we argue that there are additional advantages in developing open quantum hardware (OQH). Open quantum hardware encompasses open-source software for the control of quantum devices in labs, blueprints and open-source toolkits for chip design and other hardware components, as well as openly-accessible testbeds and facilities that allow cloud-access to a wider scientific community. We provide an overview of current projects in the OQH ecosystem, identify gaps, and make recommendations on how to close them today. More open quantum hardware would accelerate technology transfer to and growth of the quantum industry and increase accessibility in science.
△ Less
Submitted 1 March, 2024; v1 submitted 29 September, 2023;
originally announced September 2023.
-
Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs
Authors:
A. Aguilar-Arevalo,
I. Arnquist,
N. Avalos,
L. Barak,
D. Baxter,
X. Bertou,
I. M. Bloch,
A. M. Botti,
M. Cababie,
G. Cancelo,
N. Castelló-Mor,
B. A. Cervantes-Vergara,
A. E. Chavarria,
J. Cortabitarte-Gutiérrez,
M. Crisler,
J. Cuevas-Zepeda,
A. Dastgheibi-Fard,
C. De Dominicis,
O. Deligny,
A. Drlica-Wagner,
J. Duarte-Campderros,
J. C. D'Olivo,
R. Essig,
E. Estrada,
J. Estrada
, et al. (47 additional authors not shown)
Abstract:
We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. W…
▽ More
We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ${\sim}7$ events per kg-day and electron-equivalent energies of ${\sim}80~$eV, whose origin remains unknown.
△ Less
Submitted 26 March, 2024; v1 submitted 2 June, 2023;
originally announced June 2023.
-
SENSEI: Search for Millicharged Particles produced in the NuMI Beam
Authors:
Liron Barak,
Itay M. Bloch,
Ana M. Botti,
Mariano Cababie,
Gustavo Cancelo,
Luke Chaplinsky,
Michael Crisler,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Erez Etzion,
Guillermo Fernandez Moroni,
Roni Harnik,
Stephen E. Holland,
Yaron Korn,
Zhen Liu,
Sravan Munagavalasa,
Aviv Orly,
Santiago E. Perez,
Ryan Plestid,
Dario Rodrigues,
Nathan A. Saffold,
Silvia Scorza,
Aman Singal,
Miguel Sofo Haro
, et al. (6 additional authors not shown)
Abstract:
Millicharged particles appear in several extensions of the Standard Model, but have not yet been detected. These hypothetical particles could be produced by an intense proton beam striking a fixed target. We use data collected in 2020 by the SENSEI experiment in the MINOS cavern at the Fermi National Accelerator Laboratory to search for ultra-relativistic millicharged particles produced in collisi…
▽ More
Millicharged particles appear in several extensions of the Standard Model, but have not yet been detected. These hypothetical particles could be produced by an intense proton beam striking a fixed target. We use data collected in 2020 by the SENSEI experiment in the MINOS cavern at the Fermi National Accelerator Laboratory to search for ultra-relativistic millicharged particles produced in collisions of protons in the NuMI beam with a fixed graphite target. The absence of any ionization events with 3 to 6 electrons in the SENSEI data allow us to place world-leading constraints on millicharged particles for masses between 30 MeV to 380 MeV. This work also demonstrates the potential of utilizing low-threshold detectors to investigate new particles in beam-dump experiments, and motivates a future experiment designed specifically for this purpose.
△ Less
Submitted 24 May, 2023; v1 submitted 8 May, 2023;
originally announced May 2023.
-
Searching for millicharged particles with 1 kg of Skipper-CCDs using the NuMI beam at Fermilab
Authors:
Santiago Perez,
Dario Rodrigues,
Juan Estrada,
Roni Harnik,
Zhen Liu,
Brenda A. Cervantes-Vergara,
Juan Carlos D'Olivo,
Ryan D. Plestid,
Javier Tiffenberg,
Tien-Tien Yu,
Alexis Aguilar-Arevalo,
Fabricio Alcalde-Bessia,
Nicolas Avalos,
Oscar Baez,
Daniel Baxter,
Xavier Bertou,
Carla Bonifazi,
Ana Botti,
Gustavo Cancelo,
Nuria Castelló-Mor,
Alvaro E. Chavarria,
Claudio R. Chavez,
Fernando Chierchie,
Juan Manuel De Egea,
Cyrus Dreyer
, et al. (35 additional authors not shown)
Abstract:
Oscura is a planned light-dark matter search experiment using Skipper-CCDs with a total active mass of 10 kg. As part of the detector development, the collaboration plans to build the Oscura Integration Test (OIT), an engineering test with 10% of the total mass. Here we discuss the early science opportunities with the OIT to search for millicharged particles (mCPs) using the NuMI beam at Fermilab.…
▽ More
Oscura is a planned light-dark matter search experiment using Skipper-CCDs with a total active mass of 10 kg. As part of the detector development, the collaboration plans to build the Oscura Integration Test (OIT), an engineering test with 10% of the total mass. Here we discuss the early science opportunities with the OIT to search for millicharged particles (mCPs) using the NuMI beam at Fermilab. mCPs would be produced at low energies through photon-mediated processes from decays of scalar, pseudoscalar, and vector mesons, or direct Drell-Yan productions. Estimates show that the OIT would be a world-leading probe for mCPs in the MeV mass range.
△ Less
Submitted 2 December, 2023; v1 submitted 17 April, 2023;
originally announced April 2023.
-
Skipper-CCD Sensors for the Oscura Experiment: Requirements and Preliminary Tests
Authors:
Brenda A. Cervantes-Vergara,
Santiago Perez,
Juan Estrada,
Ana Botti,
Claudio R. Chavez,
Fernando Chierchie,
Nathan Saffold,
Alexis Aguilar-Arevalo,
Fabricio Alcalde-Bessia,
Nicolás Avalos,
Oscar Baez,
Daniel Baxter,
Xavier Bertou,
Carla Bonifazi,
Gustavo Cancelo,
Nuria Castelló-Mor,
Alvaro E. Chavarria,
Juan Manuel De Egea,
Juan Carlos D'Olivo,
Cyrus Dreyer,
Alex Drlica-Wagner,
Rouven Essig,
Ezequiel Estrada,
Erez Etzion,
Paul Grylls
, et al. (30 additional authors not shown)
Abstract:
Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2-10 electron ionization-signal…
▽ More
Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2-10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru. In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.
△ Less
Submitted 11 April, 2024; v1 submitted 10 April, 2023;
originally announced April 2023.
-
Entangled Photon Pair Source Demonstrator using the Quantum Instrumentation Control Kit System
Authors:
Si Xie,
Leandro Stefanazzi,
Christina Wang,
Cristian Pena,
Raju Valivarthi,
Lautaro Narvaez,
Gustavo Cancelo,
Keshav Kapoor,
Boris Korzh,
Matthew Shaw,
Panagiotis Spentzouris,
Maria Spiropulu
Abstract:
We report the first demonstration of using the Quantum Instrumentation and Control Kit (QICK) system on RFSoCFPGA technology to drive an entangled photon pair source and to detect the photon signals. With the QICK system, we achieve high levels of performance metrics including coincidence-to-accidental ratio exceeding 150, and entanglement visibility exceeding 95%, consistent with performance metr…
▽ More
We report the first demonstration of using the Quantum Instrumentation and Control Kit (QICK) system on RFSoCFPGA technology to drive an entangled photon pair source and to detect the photon signals. With the QICK system, we achieve high levels of performance metrics including coincidence-to-accidental ratio exceeding 150, and entanglement visibility exceeding 95%, consistent with performance metrics achieved using conventional waveform generators. We also demonstrate simultaneous detector readout using the digitization functional of QICK, achieving internal system synchronization time resolution of 3.2 ps. The work reported in this paper represents an explicit demonstration of the feasibility for replacing commercial waveform generators and time taggers with RFSoC-FPGA technology in the operation of a quantum network, representing a cost reduction of more than an order of magnitude.
△ Less
Submitted 3 April, 2023;
originally announced April 2023.
-
Quantum computing hardware for HEP algorithms and sensing
Authors:
M. Sohaib Alam,
Sergey Belomestnykh,
Nicholas Bornman,
Gustavo Cancelo,
Yu-Chiu Chao,
Mattia Checchin,
Vinh San Dinh,
Anna Grassellino,
Erik J. Gustafson,
Roni Harnik,
Corey Rae Harrington McRae,
Ziwen Huang,
Keshav Kapoor,
Taeyoon Kim,
James B. Kowalkowski,
Matthew J. Kramer,
Yulia Krasnikova,
Prem Kumar,
Doga Murat Kurkcuoglu,
Henry Lamm,
Adam L. Lyon,
Despina Milathianaki,
Akshay Murthy,
Josh Mutus,
Ivan Nekrashevich
, et al. (15 additional authors not shown)
Abstract:
Quantum information science harnesses the principles of quantum mechanics to realize computational algorithms with complexities vastly intractable by current computer platforms. Typical applications range from quantum chemistry to optimization problems and also include simulations for high energy physics. The recent maturing of quantum hardware has triggered preliminary explorations by several ins…
▽ More
Quantum information science harnesses the principles of quantum mechanics to realize computational algorithms with complexities vastly intractable by current computer platforms. Typical applications range from quantum chemistry to optimization problems and also include simulations for high energy physics. The recent maturing of quantum hardware has triggered preliminary explorations by several institutions (including Fermilab) of quantum hardware capable of demonstrating quantum advantage in multiple domains, from quantum computing to communications, to sensing. The Superconducting Quantum Materials and Systems (SQMS) Center, led by Fermilab, is dedicated to providing breakthroughs in quantum computing and sensing, mediating quantum engineering and HEP based material science. The main goal of the Center is to deploy quantum systems with superior performance tailored to the algorithms used in high energy physics. In this Snowmass paper, we discuss the two most promising superconducting quantum architectures for HEP algorithms, i.e. three-level systems (qutrits) supported by transmon devices coupled to planar devices and multi-level systems (qudits with arbitrary N energy levels) supported by superconducting 3D cavities. For each architecture, we demonstrate exemplary HEP algorithms and identify the current challenges, ongoing work and future opportunities. Furthermore, we discuss the prospects and complexities of interconnecting the different architectures and individual computational nodes. Finally, we review several different strategies of error protection and correction and discuss their potential to improve the performance of the two architectures. This whitepaper seeks to reach out to the HEP community and drive progress in both HEP research and QIS hardware.
△ Less
Submitted 29 April, 2022; v1 submitted 18 April, 2022;
originally announced April 2022.
-
The Oscura Experiment
Authors:
Alexis Aguilar-Arevalo,
Fabricio Alcalde Bessia,
Nicolas Avalos,
Daniel Baxter,
Xavier Bertou,
Carla Bonifazi,
Ana Botti,
Mariano Cababie,
Gustavo Cancelo,
Brenda Aurea Cervantes-Vergara,
Nuria Castello-Mor,
Alvaro Chavarria,
Claudio R. Chavez,
Fernando Chierchie,
Juan Manuel De Egea,
Juan Carlos D`Olivo,
Cyrus E. Dreyer,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Ezequiel Estrada,
Erez Etzion,
Guillermo Fernandez-Moroni,
Marivi Fernandez-Serra,
Steve Holland
, et al. (19 additional authors not shown)
Abstract:
The Oscura experiment will lead the search for low-mass dark matter particles using a very large array of novel silicon Charge Coupled Devices (CCDs) with a threshold of two electrons and with a total exposure of 30 kg-yr. The R&D effort, which began in FY20, is currently entering the design phase with the goal of being ready to start construction in late 2024. Oscura will have unprecedented sensi…
▽ More
The Oscura experiment will lead the search for low-mass dark matter particles using a very large array of novel silicon Charge Coupled Devices (CCDs) with a threshold of two electrons and with a total exposure of 30 kg-yr. The R&D effort, which began in FY20, is currently entering the design phase with the goal of being ready to start construction in late 2024. Oscura will have unprecedented sensitivity to sub-GeV dark matter particles that interact with electrons, probing dark matter-electron scattering for masses down to 500 keV and dark matter being absorbed by electrons for masses down to 1 eV. The Oscura R&D effort has made some significant progress on the main technical challenges of the experiment, of which the most significant are engaging new foundries for the fabrication of the CCD sensors, developing a cold readout solution, and understanding the experimental backgrounds.
△ Less
Submitted 23 February, 2022; v1 submitted 21 February, 2022;
originally announced February 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
Smart readout of nondestructive image sensors with single-photon sensitivity
Authors:
Fernando Chierchie,
Guillermo Fernandez Moroni,
Leandro Stefanazzi,
Eduardo Paolini,
Javier Tiffenberg,
Juan Estrada,
Gustavo Cancelo,
and Sho Uemura
Abstract:
Image sensors with nondestructive charge readout provide single-photon or single-electron sensitivity, but at the cost of long readout times. We present a smart readout technique to allow the use of these sensors in visible-light and other applications that require faster readout times. The method optimizes the readout noise and time by changing the number of times pixels are read out either stati…
▽ More
Image sensors with nondestructive charge readout provide single-photon or single-electron sensitivity, but at the cost of long readout times. We present a smart readout technique to allow the use of these sensors in visible-light and other applications that require faster readout times. The method optimizes the readout noise and time by changing the number of times pixels are read out either statically, by defining an arbitrary number of regions of interest (ROI) in the array, or dynamically, depending on the charge or energy of interest (EOI) in the pixel. This technique is tested in a Skipper CCD showing that it is possible to obtain deep sub-electron noise, and therefore, high resolution of quantized charge, while dynamically changing the readout noise of the sensor. These faster, low noise readout techniques show that the skipper CCD is a competitive technology even where other technologies such as Electron Multiplier Charge Coupled Devices (EMCCD), silicon photo multipliers, etc. are currently used. This technique could allow skipper CCDs to benefit new astronomical instruments, quantum imaging, exoplanet search and study, and quantum metrology.
△ Less
Submitted 18 November, 2021;
originally announced November 2021.
-
Characterization of the background spectrum in DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
I. Arnquist,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
N. Corso,
E. Darragh-Ford,
M. L. Di Vacri,
J. C. D'Olivo,
J. Estrada,
F. Favela-Perez,
R. Gaïor,
Y. Guardincerri,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
P. Mitra,
A. Piers,
P. Privitera,
K. Ramanathan
, et al. (9 additional authors not shown)
Abstract:
We construct the first comprehensive radioactive background model for a dark matter search with charge-coupled devices (CCDs). We leverage the well-characterized depth and energy resolution of the DAMIC at SNOLAB detector and a detailed GEANT4-based particle-transport simulation to model both bulk and surface backgrounds from natural radioactivity down to 50 eV$_{\text{ee}}$. We fit to the energy…
▽ More
We construct the first comprehensive radioactive background model for a dark matter search with charge-coupled devices (CCDs). We leverage the well-characterized depth and energy resolution of the DAMIC at SNOLAB detector and a detailed GEANT4-based particle-transport simulation to model both bulk and surface backgrounds from natural radioactivity down to 50 eV$_{\text{ee}}$. We fit to the energy and depth distributions of the observed ionization events to differentiate and constrain possible background sources, for example, bulk $^{3}$H from silicon cosmogenic activation and surface $^{210}$Pb from radon plate-out. We observe the bulk background rate of the DAMIC at SNOLAB CCDs to be as low as $3.1 \pm 0.6$ counts kg$^{-1}$ day$^{-1}$ keV$_{\text{ee}}^{-1}$, making it the most sensitive silicon dark matter detector. Finally, we discuss the properties of a statistically significant excess of events over the background model with energies below 200 eV$_{\text{ee}}$.
△ Less
Submitted 24 March, 2022; v1 submitted 25 October, 2021;
originally announced October 2021.
-
Search for coherent elastic neutrino-nucleus scattering at a nuclear reactor with CONNIE 2019 data
Authors:
CONNIE collaboration,
Alexis Aguilar-Arevalo,
Javier Bernal,
Xavier Bertou,
Carla Bonifazi,
Gustavo Cancelo,
Victor G. P. B. de Carvalho,
Brenda A. Cervantes-Vergara,
Claudio Chavez,
Gustavo Coelho Corrêa,
Juan C. D'Olivo,
João C. dos Anjos,
Juan Estrada,
Aldo R. Fernandes Neto,
Guillermo Fernandez Moroni,
Ana Foguel,
Richard Ford,
Julián Gasanego Barbuscio,
Juan Gonzalez Cuevas,
Susana Hernandez,
Federico Izraelevitch,
Ben Kilminster,
Kevin Kuk,
Herman P. Lima Jr,
Martin Makler
, et al. (11 additional authors not shown)
Abstract:
The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) is taking data at the Angra 2 nuclear reactor with the aim of detecting the coherent elastic scattering of reactor antineutrinos with silicon nuclei using charge-coupled devices (CCDs). In 2019 the experiment operated with a hardware binning applied to the readout stage, leading to lower levels of readout noise and improving the detecti…
▽ More
The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) is taking data at the Angra 2 nuclear reactor with the aim of detecting the coherent elastic scattering of reactor antineutrinos with silicon nuclei using charge-coupled devices (CCDs). In 2019 the experiment operated with a hardware binning applied to the readout stage, leading to lower levels of readout noise and improving the detection threshold down to 50 eV. The results of the analysis of 2019 data are reported here, corresponding to the detector array of 8 CCDs with a fiducial mass of 36.2 g and a total exposure of 2.2 kg-days. The difference between the reactor-on and reactor-off spectra shows no excess at low energies and yields upper limits at 95% confidence level for the neutrino interaction rates. In the lowest-energy range, 50-180 eV, the expected limit stands at 34 (39) times the standard model prediction, while the observed limit is 66 (75) times the standard model prediction with Sarkis (Chavarria) quenching factors.
△ Less
Submitted 6 April, 2022; v1 submitted 25 October, 2021;
originally announced October 2021.
-
The QICK (Quantum Instrumentation Control Kit): Readout and control for qubits and detectors
Authors:
Leandro Stefanazzi,
Ken Treptow,
Neal Wilcer,
Chris Stoughton,
Salvatore Montella,
Collin Bradford,
Gustavo Cancelo,
Shefali Saxena,
Horacio Arnaldi,
Sara Sussman,
Andrew Houck,
Ankur Agrawal,
Helin Zhang,
Chunyang Ding,
David I Schuster
Abstract:
We introduce a Xilinx RFSoC-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short) which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC (RF System-on-Chip) FPGA \cite{zcu111}, custom firmware and software…
▽ More
We introduce a Xilinx RFSoC-based qubit controller (called the Quantum Instrumentation Control Kit, or QICK for short) which supports the direct synthesis of control pulses with carrier frequencies of up to 6 GHz. The QICK can control multiple qubits or other quantum devices. The QICK consists of a digital board hosting an RFSoC (RF System-on-Chip) FPGA \cite{zcu111}, custom firmware and software and an optional companion custom-designed analog front-end board. We characterize the analog performance of the system, as well as its digital latency, important for quantum error correction and feedback protocols. We benchmark the controller by performing standard characterizations of a transmon qubit. We achieve an average Clifford gate fidelity of $\mathcal{F}_{avg}=99.93\%$. All of the schematics, firmware, and software are open-source \cite{QICKrepo}.
△ Less
Submitted 10 March, 2022; v1 submitted 1 October, 2021;
originally announced October 2021.
-
Analog pile-up circuit technique using a single capacitor for the readout of Skipper-CCD detectors
Authors:
Miguel Sofo Haro,
Claudio Chavez,
Jose Lipovetzky,
Fabricio Alcalde Bessia,
Gustavo Cancelo,
Fernando Chierchie,
Juan Estrada,
Guillermo Fernandez Moroni,
Leandro Stefanazzi,
Javier Tiffenberg,
Sho Uemura
Abstract:
With Skipper-CCD detectors it is possible to take multiple samples of the charge packet collected on each pixel. After averaging the samples, the noise can be extremely reduced allowing the exact counting of electrons per pixel. In this work we present an analog circuit that, with a minimum number of components, applies a double slope integration (DSI), and at the same time, it averages the multip…
▽ More
With Skipper-CCD detectors it is possible to take multiple samples of the charge packet collected on each pixel. After averaging the samples, the noise can be extremely reduced allowing the exact counting of electrons per pixel. In this work we present an analog circuit that, with a minimum number of components, applies a double slope integration (DSI), and at the same time, it averages the multiple samples producing at its output the pixel value with sub-electron noise. For this prupose, we introduce the technique of using the DSI integrator capacitor to add the skipper samples. An experimental verification using discrete components is presented, together with an analysis of its noise sources and limitations. After averaging 400 samples it was possible reach a readout noise of 0.2\,$e^-_{RMS}/pix$, comparable to other available readout systems. Due to its simplicity and significant reduction of the sampling requirements, this circuit technique is of particular interest in particle experiments and cameras with a high density of Skipper-CCDs.
△ Less
Submitted 20 August, 2021;
originally announced August 2021.
-
The Skipper CCD for low-energy threshold particle experiments above ground
Authors:
Guillermo Fernandez Moroni,
Fernando Chierchie,
Javier Tiffenberg,
Ana Botti,
Mariano Cababie,
Gustavo Cancelo,
Eliana L. Depaoli,
Juan Estrada,
Stephen E. Holland,
Dario Rodrigues,
Iván Sidelnik,
Miguel Sofo Haro,
Leandro Stefanazzi,
Sho Uemura
Abstract:
We present experimental results using a single-electron resolution Skipper-CCD running above ground level to demonstrate the potential of this technology for its use in reactor neutrino observations and other low-energy particle interaction experiments. Operating conditions and event-selection criteria are provided to decouple most of the background rate at low energies. Our final results for even…
▽ More
We present experimental results using a single-electron resolution Skipper-CCD running above ground level to demonstrate the potential of this technology for its use in reactor neutrino observations and other low-energy particle interaction experiments. Operating conditions and event-selection criteria are provided to decouple most of the background rate at low energies. Our final results for events with energies as low as $5$ ionized electron-hole pairs show that the exponentially increasing rate of events seen in other technologies is not present in our data. This demonstrates that the Skipper CCD proves to be among the best options to measure low energy and weakly interacting particles at ground level.
△ Less
Submitted 30 August, 2021; v1 submitted 30 June, 2021;
originally announced July 2021.
-
SENSEI: Characterization of Single-Electron Events Using a Skipper-CCD
Authors:
Liron Barak,
Itay M. Bloch,
Ana Botti,
Mariano Cababie,
Gustavo Cancelo,
Luke Chaplinsky,
Fernando Chierchie,
Michael Crisler,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Erez Etzion,
Guillermo Fernandez Moroni,
Daniel Gift,
Stephen E. Holland,
Sravan Munagavalasa,
Aviv Orly,
Dario Rodrigues,
Aman Singal,
Miguel Sofo Haro,
Leandro Stefanazzi,
Javier Tiffenberg,
Sho Uemura,
Tomer Volansky,
Tien-Tien Yu
Abstract:
We use a science-grade Skipper Charge Coupled Device (Skipper-CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as "dark counts": dark curren…
▽ More
We use a science-grade Skipper Charge Coupled Device (Skipper-CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as "dark counts": dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89+-0.77)x10^-4 e-/pix/day, and an unprecedentedly low spurious charge contribution of (1.52+-0.07)x10^-4 e-/pix, which is exposure-independent. In addition, we provide a technique to study events produced by light emitted from the amplifier, which allows the detector's operation to be optimized to minimize this effect to a level below the dark-current contribution. Our accurate characterization of the single-electron events allows one to greatly extend the sensitivity of experiments searching for dark matter or coherent neutrino scattering. Moreover, an accurate understanding of the origin of single-electron events is critical to further progress in ongoing R&D efforts of Skipper and conventional CCDs.
△ Less
Submitted 26 January, 2022; v1 submitted 15 June, 2021;
originally announced June 2021.
-
Smart-readout of the Skipper-CCD: Achieving Sub-electron Noise Levels in Regions of Interest
Authors:
Fernando Chierchie,
Guillermo Fernandez Moroni,
Leandro Stefanazzi,
Claudio Chavez,
Eduardo Paolini,
Gustavo Cancelo,
Miguel Sofo Haro,
Javier Tiffenberg,
Juan Estrada,
Sho Uemura
Abstract:
The skipper CCD is a special type of charge coupled device in which the readout noise can be reduced to sub-electron levels by averaging independent measurements of the same charge. Thus the charge in the pixels can be determined by counting the exact number of electrons. The total readout time is proportional to the number of measurements of the charge in each pixel. For some applications this ti…
▽ More
The skipper CCD is a special type of charge coupled device in which the readout noise can be reduced to sub-electron levels by averaging independent measurements of the same charge. Thus the charge in the pixels can be determined by counting the exact number of electrons. The total readout time is proportional to the number of measurements of the charge in each pixel. For some applications this time may be too long; however, researchers usually are interested only on certain region within the matrix of pixels. In this paper we present the development of a smart skipper readout technique that allows the user to specify regions of interest of the CCD matrix where an arbitrary (high) number of measurements of the same charge can taken to obtain the desired noise level, and far less measurements are performed in those regions that are less interesting to the researcher, therefore reducing the total readout time.
△ Less
Submitted 18 December, 2020;
originally announced December 2020.
-
Measurement of the bulk radioactive contamination of detector-grade silicon with DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
E. Darragh-Ford,
J. C. D'Olivo,
J. Estrada,
F. Favela-Perez,
R. Gaïor,
Y. Guardincerri,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
P. Mitra,
A. Piers,
P. Privitera,
K. Ramanathan,
J. Da Rocha,
Y. Sarkis,
M. Settimo
, et al. (6 additional authors not shown)
Abstract:
We present measurements of bulk radiocontaminants in the high-resistivity silicon CCDs from the DAMIC at SNOLAB experiment. We utilize the exquisite spatial resolution of CCDs to discriminate between $α$ and $β$ decays, and to search with high efficiency for the spatially-correlated decays of various radioisotope sequences. Using spatially-correlated $β$ decays, we measure a bulk radioactive conta…
▽ More
We present measurements of bulk radiocontaminants in the high-resistivity silicon CCDs from the DAMIC at SNOLAB experiment. We utilize the exquisite spatial resolution of CCDs to discriminate between $α$ and $β$ decays, and to search with high efficiency for the spatially-correlated decays of various radioisotope sequences. Using spatially-correlated $β$ decays, we measure a bulk radioactive contamination of $^{32}$Si in the CCDs of $140 \pm 30$ $μ$Bq/kg, and place an upper limit on bulk $^{210}$Pb of $< 160~μ$Bq/kg. Using similar analyses of spatially-correlated bulk $α$ decays, we set limits of $< 11$ $μ$Bq/kg (0.9 ppt) on $^{238}$U and of $< 7.3$ $μ$Bq/kg (1.8 ppt) on $^{232}$Th. The ability of DAMIC CCDs to identify and reject spatially-coincident backgrounds, particularly from $^{32}$Si, has significant implications for the next generation of silicon-based dark matter experiments, where $β$'s from $^{32}$Si decay will likely be a dominant background. This capability demonstrates the readiness of the CCD technology to achieve kg-scale dark matter sensitivity.
△ Less
Submitted 23 July, 2021; v1 submitted 25 November, 2020;
originally announced November 2020.
-
Second Generation Readout For Large Format Photon Counting Microwave Kinetic Inductance Detectors
Authors:
Neelay Fruitwala,
Paschal Strader,
Gustavo Cancelo,
Ted Zmuda,
Ken Treptow,
Neal Wilcer,
Chris Stoughton,
Alex B. Walter,
Nicholas Zobrist,
Giulia Collura,
Isabel Lipartito,
John I. Bailey III,
Benjamin A. Mazin
Abstract:
We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-IR wavelength bands. Our system retains much of the core signal processing architecture from the first generation system, but with a significantly higher bandwidth, enabling readout of kilopixel MKID arrays. Each set of r…
▽ More
We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-IR wavelength bands. Our system retains much of the core signal processing architecture from the first generation system, but with a significantly higher bandwidth, enabling readout of kilopixel MKID arrays. Each set of readout boards is capable of reading out 1024 MKID pixels multiplexed over 2 GHz of bandwidth; two such units can be placed in parallel to read out a full 2048 pixel microwave feedline over a 4 -- 8 GHz band. As in the first generation readout, our system is capable of identifying, analyzing, and recording photon detection events in real time with a time resolution of order a few microseconds. Here, we describe the hardware and firmware, and present an analysis of the noise properties of the system. We also present a novel algorithm for efficiently suppressing IQ mixer sidebands to below -30 dBc.
△ Less
Submitted 12 November, 2020;
originally announced November 2020.
-
A measurement of absolute efficiency of the ARAPUCA photon detector in Liquid Argon
Authors:
Dante Totani,
Gustavo Cancelo,
Flavio Cavanna,
Carlos O. Escobar,
Ernesto Kemp,
Franciole Marinho,
Laura Paulucci,
Dung D. Phan,
Stuart Mufson,
Chris Macias,
David Warner
Abstract:
In the Fall of 2017, two photon detector designs for the Deep Underground Neutrino Experiment (DUNE) Far Detector were installed and tested in the TallBo liquid argon (LAr) cryostat at the Proton Assembly (PAB) facility, Fermilab. The designs include two light bars developed at Indiana University and a photon detector based on the ARAPUCA light trap engineered by Colorado State University and Ferm…
▽ More
In the Fall of 2017, two photon detector designs for the Deep Underground Neutrino Experiment (DUNE) Far Detector were installed and tested in the TallBo liquid argon (LAr) cryostat at the Proton Assembly (PAB) facility, Fermilab. The designs include two light bars developed at Indiana University and a photon detector based on the ARAPUCA light trap engineered by Colorado State University and Fermilab. The performance of these devices is determined by analyzing 8 weeks of cosmic ray data. The current paper focuses solely on the ARAPUCA device as the performance of the light bars will be reported separately. The paper briefly describes the ARAPUCA concept, the TallBo setup, and focuses on data analysis and results.
△ Less
Submitted 12 August, 2020;
originally announced August 2020.
-
Results on Low-Mass Weakly Interacting Massive Particles from an 11 kg-day Target Exposure of DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
J. C. D'Olivo,
J. Estrada,
F. Favela-Perez,
R. Gaior,
Y. Guardincerri,
E. W. Hoppe,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
P. Mitra,
C. T. Overman,
A. Piers,
P. Privitera,
K. Ramanathan,
J. Da Rocha,
Y. Sarkis
, et al. (7 additional authors not shown)
Abstract:
We present constraints on the existence of weakly interacting massive particles (WIMPs) from an 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An exces…
▽ More
We present constraints on the existence of weakly interacting massive particles (WIMPs) from an 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An excess of ionization events is observed above the analysis threshold of 50 eV$_{\rm ee}$. While the origin of this low-energy excess requires further investigation, our data exclude spin-independent WIMP-nucleon scattering cross sections $σ_{χ-n}$ as low as $3\times 10^{-41}$ cm$^2$ for WIMPs with masses $m_χ$ from 7 to 10 GeV$c^{-2}$ . These results are the strongest constraints from a silicon target on the existence of WIMPs with $m_χ$$<$9 GeV$c^{-2}$ and are directly relevant to any dark matter interpretation of the excess of nuclear-recoil events observed by the CDMS silicon experiment in 2013.
△ Less
Submitted 25 December, 2020; v1 submitted 30 July, 2020;
originally announced July 2020.
-
Absolute measurement of the Fano factor using a Skipper-CCD
Authors:
Dario Rodrigues,
Kevin Andersson,
Mariano Cababie,
Andre Donadon,
Ana Botti,
Gustavo Cancelo,
Juan Estrada,
Guillermo Fernandez-Moroni,
Ricardo Piegaia,
Matias Senger,
Miguel Sofo Haro,
Leandro Stefanazzi,
Javier Tiffenberg,
Sho Uemura
Abstract:
Skipper-CCD can achieve deep sub-electron readout noise making possible the absolute determination of the exact number of ionized electrons in a large range, from 0 to above 1900 electrons. In this work we present a novel technique that exploits this unique capability to allow self-calibration and the ultimate determination of silicon properties. We performed an absolute measurement of the varianc…
▽ More
Skipper-CCD can achieve deep sub-electron readout noise making possible the absolute determination of the exact number of ionized electrons in a large range, from 0 to above 1900 electrons. In this work we present a novel technique that exploits this unique capability to allow self-calibration and the ultimate determination of silicon properties. We performed an absolute measurement of the variance and the mean number of the charge distribution produced by $^{55}$Fe X-rays, getting a Fano factor absolute measurement in Si at 123K and 5.9 keV. A value of 0.119 $\pm$ 0.002 was found and the electron-hole pair creation energy was determined to be (3.749 $\pm$ 0.001) eV. This technology opens the opportunity for direct measurements of the Fano factor at low energies.
△ Less
Submitted 6 November, 2020; v1 submitted 23 April, 2020;
originally announced April 2020.
-
SENSEI: Direct-Detection Results on sub-GeV Dark Matter from a New Skipper-CCD
Authors:
Liron Barak,
Itay M. Bloch,
Mariano Cababie,
Gustavo Cancelo,
Luke Chaplinsky,
Fernando Chierchie,
Michael Crisler,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Erez Etzion,
Guillermo Fernandez Moroni,
Daniel Gift,
Sravan Munagavalasa,
Aviv Orly,
Dario Rodrigues,
Aman Singal,
Miguel Sofo Haro,
Leandro Stefanazzi,
Javier Tiffenberg,
Sho Uemura,
Tomer Volansky,
Tien-Tien Yu
Abstract:
We present the first direct-detection search for eV-to-GeV dark matter using a new ~2-gram high-resistivity Skipper-CCD from a dedicated fabrication batch that was optimized for dark-matter searches. Using 24 days of data acquired in the MINOS cavern at the Fermi National Accelerator Laboratory, we measure the lowest rates in silicon detectors of events containing one, two, three, or four electron…
▽ More
We present the first direct-detection search for eV-to-GeV dark matter using a new ~2-gram high-resistivity Skipper-CCD from a dedicated fabrication batch that was optimized for dark-matter searches. Using 24 days of data acquired in the MINOS cavern at the Fermi National Accelerator Laboratory, we measure the lowest rates in silicon detectors of events containing one, two, three, or four electrons, and achieve world-leading sensitivity for a large range of sub-GeV dark matter masses. Data taken with different thicknesses of the detector shield suggest a correlation between the rate of high-energy tracks and the rate of single-electron events previously classified as "dark current." We detail key characteristics of the new Skipper-CCDs, which augur well for the planned construction of the ~100-gram SENSEI experiment at SNOLAB.
△ Less
Submitted 2 November, 2020; v1 submitted 23 April, 2020;
originally announced April 2020.
-
Low Threshold Acquisition controller for Skipper CCDs
Authors:
Gustavo Cancelo,
Claudio Chavez,
Fernando Chierchie,
Juan Estrada,
Guillermo Fernandez Moroni,
Eduardo Emilio Paolini,
Miguel Sofo Haro,
Angel Soto,
Leandro Stefanazzi,
Javier Tiffenberg,
Ken Treptow,
Neal Wilcer,
Ted Zmuda
Abstract:
The development of the Skipper Charge Coupled Devices (Skipper-CCDs) has been a major technological breakthrough for sensing very weak ionizing particles. The sensor allows to reach the ultimate sensitivity of silicon material as a charge signal sensor by unambiguous determination of the charge signal collected by each cell or pixel, even for single electron-hole pair ionization. Extensive use of…
▽ More
The development of the Skipper Charge Coupled Devices (Skipper-CCDs) has been a major technological breakthrough for sensing very weak ionizing particles. The sensor allows to reach the ultimate sensitivity of silicon material as a charge signal sensor by unambiguous determination of the charge signal collected by each cell or pixel, even for single electron-hole pair ionization. Extensive use of the technology was limited by the lack of specific equipment to operate the sensor at the ultimate performance. In this work a simple, single-board Skipper-CCD controller is presented, aimed for the operation of the detector in high sensitivity scientific applications. The article describes the main components and functionality of the Low Threshold Acquisition (LTA) together with experimental results when connected to a Skipper-CCD sensor. Measurements show unprecedented deep sub-electron noise of 0.039 e$^-_{rms}$/pix for 5000 pixel measurements.
△ Less
Submitted 16 April, 2020;
originally announced April 2020.
-
Interplay between phonon downconversion efficiency, density of states at Fermi energy, and intrinsic energy resolution for microwave kinectic inductance detectors
Authors:
Israel Hernandez,
Gustavo Cancelo,
Juan Estrada,
Humberto Gonzalez,
Andrew Lathrop,
Martin Makler,
Chris Stoughto
Abstract:
Microwave Kinetic Inductance detectors (MKIDs) have been recognized as a powerful new tool for single photon detection. These highly multiplexed superconducting devices give timing and energy measurement for every detected photon. However, the full potential of MKID single photon spectroscopy has not been reached , the achieved energy resolution is lower than expected from first principles. Here,…
▽ More
Microwave Kinetic Inductance detectors (MKIDs) have been recognized as a powerful new tool for single photon detection. These highly multiplexed superconducting devices give timing and energy measurement for every detected photon. However, the full potential of MKID single photon spectroscopy has not been reached , the achieved energy resolution is lower than expected from first principles. Here, we study the efficiency in the phonon downconversion process following the absorption of energetic photons in MKIDs. Assuming previously published material properties, we measure an average downconversion efficiency for three TiN resonators is $η$=0.14. We discuss how this efficiency can impact the intrinsic energy resolution of MKID, and how any uncertainty in the unknown density of electron states at the Fermi energy directly affects the efficiency estimations.
△ Less
Submitted 6 April, 2020;
originally announced April 2020.
-
Differences in the response of two light guide technologies and two readout technologies after an exchange of liquid argon in the dewar
Authors:
S. Mufson,
B. Adams,
B. Baugh,
B. Howard,
C. Macias,
G. Cancelo,
E. Niner,
D. Totani
Abstract:
In this investigation the response to the scintillation light generated by through-going cosmic muons in liquid argon (LAr) was measured by two light guide technologies and two readout technologies after five weeks of running in the TallBo dewar at Fermilab. The response was remeasured after the dewar was drained of LAr, refilled, and then run again for an additional four weeks. After the dewar wa…
▽ More
In this investigation the response to the scintillation light generated by through-going cosmic muons in liquid argon (LAr) was measured by two light guide technologies and two readout technologies after five weeks of running in the TallBo dewar at Fermilab. The response was remeasured after the dewar was drained of LAr, refilled, and then run again for an additional four weeks. After the dewar was refilled, there was clear evidence that the scintillation signal had dropped significantly. The two light guide technologies were developed at Indiana University and MIT/Fermilab. The two readout technologies were boards that passively or actively ganged 12 Hamamatsu MPPCs. Two possible explanations were identified for the degraded signal: the response of the two light guide technologies degraded due to damage caused by thermal cycling, and/or unknown differences in the trace residual Xe contamination in the fills of LAr led to the observed drop in scintillation light. Neither absorption nor quenching by N2, O2, and H2O contamination can account for the degradation. Neither the individual Hamamatsu MPPCs nor the passive/active ganging boards appear to have been affected by the thermal cycling. The path length distributions of the cosmics traversing the dewar appear quite similar in both event samples.
△ Less
Submitted 17 June, 2020; v1 submitted 12 December, 2019;
originally announced December 2019.
-
Search for light mediators in the low-energy data of the CONNIE reactor neutrino experiment
Authors:
Alexis Aguilar-Arevalo,
Xavier Bertou,
Carla Bonifazi,
Gustavo Cancelo,
Brenda A. Cervantes-Vergara,
Claudio Chavez,
Juan C. D'Olivo,
João C. dos Anjos,
Juan Estrada,
Aldo R. Fernandes Neto,
Guillermo Fernandez-Moroni,
Ana Foguel,
Richard Ford,
Federico Izraelevitch,
Ben Kilminster,
H. P. Lima Jr,
Martin Makler,
Jorge Molina,
Philipe Mota,
Irina Nasteva,
Eduardo Paolini,
Carlos Romero,
Youssef Sarkis,
Miguel Sofo-Haro,
Javier Tiffenberg
, et al. (1 additional authors not shown)
Abstract:
The CONNIE experiment is located at a distance of 30 m from the core of a commercial nuclear reactor, and has collected a 3.7 kg-day exposure using a CCD detector array sensitive to an $\sim$1 keV threshold for the study of coherent neutrino-nucleus elastic scattering. Here we demonstrate the potential of this low-energy neutrino experiment as a probe for physics Beyond the Standard Model, by usin…
▽ More
The CONNIE experiment is located at a distance of 30 m from the core of a commercial nuclear reactor, and has collected a 3.7 kg-day exposure using a CCD detector array sensitive to an $\sim$1 keV threshold for the study of coherent neutrino-nucleus elastic scattering. Here we demonstrate the potential of this low-energy neutrino experiment as a probe for physics Beyond the Standard Model, by using the recently published results to constrain two simplified extensions of the Standard Model with light mediators. We compare the new limits with those obtained for the same models using neutrinos from the Spallation Neutron Source. Our new constraints represent the best limits for these simplified models among the experiments searching for CE$ν$NS for a light vector mediator with mass $M_{Z^{\prime}}<$ 10 MeV, and for a light scalar mediator with mass $M_φ<$ 30 MeV. These results constitute the first use of the CONNIE data as a probe for physics Beyond the Standard Model.
△ Less
Submitted 29 March, 2020; v1 submitted 10 October, 2019;
originally announced October 2019.
-
Constraints on Light Dark Matter Particles Interacting with Electrons from DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
D. Baxter,
G. Cancelo,
B. A. Cervantes Vergara,
A. E. Chavarria,
E. Darragh-Ford,
J. R. T. de Mello Neto,
J. C. D'Olivo,
J. Estrada,
R. Gaïor,
Y. Guardincerri,
T. W. Hossbach,
B. Kilminster,
I. Lawson,
S. J. Lee,
A. Letessier-Selvon,
A. Matalon,
V. B. B. Mello,
P. Mitra,
Y. S. Mobarak,
J. Molina,
S. Paul,
A. Piers,
P. Privitera
, et al. (9 additional authors not shown)
Abstract:
We report direct-detection constraints on light dark matter particles interacting with electrons. The results are based on a method that exploits the extremely low levels of leakage current of the DAMIC detector at SNOLAB of 2-6$\times$10$^{-22}$ A cm$^{-2}$. We evaluate the charge distribution of pixels that collect $<10~\rm{e^-}$ for contributions beyond the leakage current that may be attribute…
▽ More
We report direct-detection constraints on light dark matter particles interacting with electrons. The results are based on a method that exploits the extremely low levels of leakage current of the DAMIC detector at SNOLAB of 2-6$\times$10$^{-22}$ A cm$^{-2}$. We evaluate the charge distribution of pixels that collect $<10~\rm{e^-}$ for contributions beyond the leakage current that may be attributed to dark matter interactions. Constraints are placed on so-far unexplored parameter space for dark matter masses between 0.6 and 100 MeV$c^{-2}$. We also present new constraints on hidden-photon dark matter with masses in the range $1.2$-$30$ eV$c^{-2}$.
△ Less
Submitted 8 April, 2020; v1 submitted 29 July, 2019;
originally announced July 2019.
-
Exploring low-energy neutrino physics with the Coherent Neutrino Nucleus Interaction Experiment (CONNIE)
Authors:
Alexis Aguilar-Arevalo,
Xavier Bertou,
Carla Bonifazi,
Gustavo Cancelo,
Alejandro Castañeda,
Brenda Cervantes Vergara,
Claudio Chavez,
Juan C. D'Olivo,
João C. dos Anjos,
Juan Estrada,
Aldo R. Fernandes Neto,
Guillermo Fernandez Moroni,
Ana Foguel,
Richard Ford,
Juan Gonzalez Cuevas,
Pamela Hernández,
Susana Hernandez,
Federico Izraelevitch,
Alexander R. Kavner,
Ben Kilminster,
Kevin Kuk,
H. P. Lima Jr,
Martin Makler,
Jorge Molina,
Philipe Mota
, et al. (8 additional authors not shown)
Abstract:
The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) uses low-noise fully depleted charge-coupled devices (CCDs) with the goal of measuring low-energy recoils from coherent elastic scattering (CE$ν$NS) of reactor antineutrinos with silicon nuclei and testing nonstandard neutrino interactions (NSI). We report here the first results of the detector array deployed in 2016, considering an act…
▽ More
The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) uses low-noise fully depleted charge-coupled devices (CCDs) with the goal of measuring low-energy recoils from coherent elastic scattering (CE$ν$NS) of reactor antineutrinos with silicon nuclei and testing nonstandard neutrino interactions (NSI). We report here the first results of the detector array deployed in 2016, considering an active mass 47.6 g (8 CCDs), which is operating at a distance of 30 m from the core of the Angra 2 nuclear reactor, with a thermal power of 3.8 GW. A search for neutrino events is performed by comparing data collected with reactor on (2.1 kg-day) and reactor off (1.6 kg-day). The results show no excess in the reactor-on data, reaching the world record sensitivity down to recoil energies of about 1 keV (0.1 keV electron-equivalent). A 95% confidence level limit for new physics is established at an event rate of 40 times the one expected from the standard model at this energy scale. The results presented here provide a new window to low-energy neutrino physics, allowing one to explore for the first time the energies accessible through the low threshold of CCDs. They will lead to new constrains on NSI from the CE$ν$NS of antineutrinos from nuclear reactors.
△ Less
Submitted 10 October, 2019; v1 submitted 5 June, 2019;
originally announced June 2019.
-
The DUNE Far Detector Interim Design Report, Volume 3: Dual-Phase Module
Authors:
DUNE Collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
L. Aliaga Soplin,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
A. Ankowski,
J. Anthony,
M. Antonello,
M. Antonova
, et al. (1076 additional authors not shown)
Abstract:
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable…
▽ More
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 3 describes the dual-phase module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
The DUNE Far Detector Interim Design Report Volume 1: Physics, Technology and Strategies
Authors:
DUNE Collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
L. Aliaga Soplin,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
A. Ankowski,
J. Anthony,
M. Antonello,
M. Antonova
, et al. (1076 additional authors not shown)
Abstract:
The DUNE IDR describes the proposed physics program and technical designs of the DUNE Far Detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable…
▽ More
The DUNE IDR describes the proposed physics program and technical designs of the DUNE Far Detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 1 contains an executive summary that describes the general aims of this document. The remainder of this first volume provides a more detailed description of the DUNE physics program that drives the choice of detector technologies. It also includes concise outlines of two overarching systems that have not yet evolved to consortium structures: computing and calibration. Volumes 2 and 3 of this IDR describe, for the single-phase and dual-phase technologies, respectively, each detector module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
The DUNE Far Detector Interim Design Report, Volume 2: Single-Phase Module
Authors:
DUNE Collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
L. Aliaga Soplin,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
A. Ankowski,
J. Anthony,
M. Antonello,
M. Antonova
, et al. (1076 additional authors not shown)
Abstract:
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable…
▽ More
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 2 describes the single-phase module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
Quantum Sensing for High Energy Physics
Authors:
Zeeshan Ahmed,
Yuri Alexeev,
Giorgio Apollinari,
Asimina Arvanitaki,
David Awschalom,
Karl K. Berggren,
Karl Van Bibber,
Przemyslaw Bienias,
Geoffrey Bodwin,
Malcolm Boshier,
Daniel Bowring,
Davide Braga,
Karen Byrum,
Gustavo Cancelo,
Gianpaolo Carosi,
Tom Cecil,
Clarence Chang,
Mattia Checchin,
Sergei Chekanov,
Aaron Chou,
Aashish Clerk,
Ian Cloet,
Michael Crisler,
Marcel Demarteau,
Ranjan Dharmapalan
, et al. (91 additional authors not shown)
Abstract:
Report of the first workshop to identify approaches and techniques in the domain of quantum sensing that can be utilized by future High Energy Physics applications to further the scientific goals of High Energy Physics.
Report of the first workshop to identify approaches and techniques in the domain of quantum sensing that can be utilized by future High Energy Physics applications to further the scientific goals of High Energy Physics.
△ Less
Submitted 29 March, 2018;
originally announced March 2018.
-
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-Contrast Astronomy
Authors:
Seth R. Meeker,
Benjamin A. Mazin,
Alex B. Walter,
Paschal Strader,
Neelay Fruitwala,
Clint Bockstiegel,
Paul Szypryt,
Gerhard Ulbricht,
Gregoire Coiffard,
Bruce Bumble,
Gustavo Cancelo,
Ted Zmuda,
Ken Treptow,
Neal Wilcer,
Giulia Collura,
Rupert Dodkins,
Isabel Lipartito,
Nicholas Zobrist,
Michael Bottom,
J. Chris Shelton,
Dimitri Mawet,
Julian C. van Eyken,
Gautam Vasisht,
Eugene Serabyn
Abstract:
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving Superconducting Spectrophotometer), the first of several planned integral field spectrographs to use optical/near-infrared Microwave Kinetic Inductance Detectors (MKIDs) for high-contrast imaging. The photon counting and simultaneous low-resolution spectroscopy provided by MKIDs will enable real-time speckle control techniques an…
▽ More
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving Superconducting Spectrophotometer), the first of several planned integral field spectrographs to use optical/near-infrared Microwave Kinetic Inductance Detectors (MKIDs) for high-contrast imaging. The photon counting and simultaneous low-resolution spectroscopy provided by MKIDs will enable real-time speckle control techniques and post-processing speckle suppression at framerates capable of resolving the atmospheric speckles that currently limit high-contrast imaging from the ground. DARKNESS is now operational behind the PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at Palomar Observatory. Here we describe the motivation, design, and characterization of the instrument, early on-sky results, and future prospects.
△ Less
Submitted 16 April, 2018; v1 submitted 28 March, 2018;
originally announced March 2018.
-
Increasing the efficiency of photon collection in LArTPCs: the ARAPUCA light trap
Authors:
G. Cancelo,
F. Cavanna,
C. O. Escobar,
E. Kemp,
A. A. Machado,
A. Para,
E. Segreto,
D. Totani,
D. Warner
Abstract:
The Liquid Argon Time Projection Chambers (LArTPCs) are a choice for the next generation of large neutrino detectors due to their optimal performance in particle tracking and calorimetry. The detection of Argon scintillation light plays a crucial role in the event reconstruction as well as the time reference for non-beam physics such as supernovae neutrino detection and baryon number violation stu…
▽ More
The Liquid Argon Time Projection Chambers (LArTPCs) are a choice for the next generation of large neutrino detectors due to their optimal performance in particle tracking and calorimetry. The detection of Argon scintillation light plays a crucial role in the event reconstruction as well as the time reference for non-beam physics such as supernovae neutrino detection and baryon number violation studies. In this contribution, we present the current R&D work on the ARAPUCA (Argon R&D Advanced Program at UNICAMP), a light trap device to enhance Ar scintillation light collection and thus the overall performance of LArTPCs. The ARAPUCA working principle is based on a suitable combination of dichroic filters and wavelength shifters to achieve a high efficiency in light collection. We discuss the operational principles, the last results of laboratory tests and the application of the ARAPUCA as the alternative photon detection system in the protoDUNE detector.
△ Less
Submitted 5 March, 2018; v1 submitted 27 February, 2018;
originally announced February 2018.
-
A measurement of the ionization efficiency of nuclear recoils in silicon
Authors:
F. Izraelevitch,
D. Amidei,
A. Aprahamian,
R. Arcos-Olalla,
G. Cancelo,
C. Casarella,
A. E. Chavarria,
P. Collon,
J. Estrada,
G. Fernández Moroni,
Y. Guardincerri,
G. Gutiérrez,
A. Gyurjinyan,
A. Kavner,
B. Kilminster,
A. Lathrop,
J. Liao,
Q. Liu,
M. López,
J. Molina,
P. Privitera,
M. A. Reyes,
V. Scarpine,
K. Siegl,
M. Smith
, et al. (4 additional authors not shown)
Abstract:
We have measured the ionization efficiency of silicon nuclear recoils with kinetic energy between 1.8 and 20 keV. We bombarded a silicon-drift diode with a neutron beam to perform an elastic-scattering experiment. A broad-energy neutron spectrum was used and the nuclear recoil energy was reconstructed using a measurement of the time of flight and scattering angle of the scattered neutron. The over…
▽ More
We have measured the ionization efficiency of silicon nuclear recoils with kinetic energy between 1.8 and 20 keV. We bombarded a silicon-drift diode with a neutron beam to perform an elastic-scattering experiment. A broad-energy neutron spectrum was used and the nuclear recoil energy was reconstructed using a measurement of the time of flight and scattering angle of the scattered neutron. The overall trend of the results of this work is well described by the theory of Lindhard et al. above 4 keV of recoil energy. Below this energy, the presented data shows a deviation from the model. The data indicates a faster drop than the theory prediction at low energies.
△ Less
Submitted 4 July, 2017; v1 submitted 2 February, 2017;
originally announced February 2017.
-
First Direct-Detection Constraints on eV-Scale Hidden-Photon Dark Matter with DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
B. A. Cervantes Vergara,
A. E. Chavarria,
C. R. Chavez,
J. R. T. de Mello Neto,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
R. Gaïor,
Y. Guardincerri,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
A. Letessier-Selvon,
J. Liao,
A. Matalon,
V. B. B. Mello,
J. Molina
, et al. (13 additional authors not shown)
Abstract:
We present direct detection constraints on the absorption of hidden-photon dark matter with particle masses in the range 1.2-30 eV$c^{-2}$ with the DAMIC experiment at SNOLAB. Under the assumption that the local dark matter is entirely constituted of hidden photons, the sensitivity to the kinetic mixing parameter $κ$ is competitive with constraints from solar emission, reaching a minimum value of…
▽ More
We present direct detection constraints on the absorption of hidden-photon dark matter with particle masses in the range 1.2-30 eV$c^{-2}$ with the DAMIC experiment at SNOLAB. Under the assumption that the local dark matter is entirely constituted of hidden photons, the sensitivity to the kinetic mixing parameter $κ$ is competitive with constraints from solar emission, reaching a minimum value of 2.2$\times$$10^{-14}$ at 17 eV$c^{-2}$. These results are the most stringent direct detection constraints on hidden-photon dark matter in the galactic halo with masses 3-12 eV$c^{-2}$ and the first demonstration of direct experimental sensitivity to ionization signals $<$12 eV from dark matter interactions.
△ Less
Submitted 11 April, 2017; v1 submitted 9 November, 2016;
originally announced November 2016.
-
The CONNIE experiment
Authors:
CONNIE Collaboration,
A. Aguilar-Arevalo,
X. Bertou,
C. Bonifazi,
M. Butner,
G. Cancelo,
A. Castaneda Vazquez,
B. Cervantes Vergara,
C. R. Chavez,
H. Da Motta,
J. C. D'Olivo,
J. Dos Anjos,
J. Estrada,
G. Fernandez Moroni,
R. Ford,
A. Foguel,
K. P. Hernandez Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
K. Kuk,
H. P. Lima Jr.,
M. Makler,
J. Molina,
G. Moreno-Granados
, et al. (6 additional authors not shown)
Abstract:
The CONNIE experiment uses fully depleted, high resistivity CCDs as particle detectors in an attempt to measure for the first time the Coherent Neutrino-Nucleus Elastic Scattering of antineutrinos from a nuclear reactor with silicon nuclei.This talk, given at the XV Mexican Workshop on Particles and Fields (MWPF), discussed the potential of CONNIE to perform this measurement, the installation prog…
▽ More
The CONNIE experiment uses fully depleted, high resistivity CCDs as particle detectors in an attempt to measure for the first time the Coherent Neutrino-Nucleus Elastic Scattering of antineutrinos from a nuclear reactor with silicon nuclei.This talk, given at the XV Mexican Workshop on Particles and Fields (MWPF), discussed the potential of CONNIE to perform this measurement, the installation progress at the Angra dos Reis nuclear power plant, as well as the plans for future upgrades.
△ Less
Submitted 10 October, 2016; v1 submitted 4 August, 2016;
originally announced August 2016.
-
Search for low-mass WIMPs in a 0.6 kg day exposure of the DAMIC experiment at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
B. A. Cervantes Vergara,
A. E. Chavarria,
C. R. Chavez,
J. R. T. de Mello Neto,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
R. Gaïor,
Y. Guandincerri,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
A. Letessier-Selvon,
J. Liao,
J. Molina,
J. R. Peña,
P. Privitera
, et al. (13 additional authors not shown)
Abstract:
We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic…
▽ More
We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic-scattering cross section are accordingly placed. A region of parameter space relevant to the potential signal from the CDMS-II Si experiment is excluded using the same target for the first time. This result obtained with a limited exposure demonstrates the potential to explore the low-mass WIMP region (<10 GeV/$c^{2}$) of the upcoming DAMIC100, a 100 g detector currently being installed in SNOLAB.
△ Less
Submitted 9 November, 2016; v1 submitted 25 July, 2016;
originally announced July 2016.