Extraction of the Muon Signals Recorded with the Surface Detector of the Pierre Auger Observatory Using Recurrent Neural Networks
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
J. M. Albury,
I. Allekotte,
A. Almela,
J. Alvarez-Muñiz,
R. Alves Batista,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
P. R. Araújo Ferreira,
J. C. Arteaga Velázquez,
H. Asorey,
P. Assis,
G. Avila,
A. M. Badescu,
A. Bakalova,
A. Balaceanu,
F. Barbato,
R. J. Barreira Luz,
K. H. Becker
, et al. (348 additional authors not shown)
Abstract:
The Pierre Auger Observatory, at present the largest cosmic-ray observatory ever built, is instrumented with a ground array of 1600 water-Cherenkov detectors, known as the Surface Detector (SD). The SD samples the secondary particle content (mostly photons, electrons, positrons and muons) of extensive air showers initiated by cosmic rays with energies ranging from $10^{17}~$eV up to more than…
▽ More
The Pierre Auger Observatory, at present the largest cosmic-ray observatory ever built, is instrumented with a ground array of 1600 water-Cherenkov detectors, known as the Surface Detector (SD). The SD samples the secondary particle content (mostly photons, electrons, positrons and muons) of extensive air showers initiated by cosmic rays with energies ranging from $10^{17}~$eV up to more than $10^{20}~$eV. Measuring the independent contribution of the muon component to the total registered signal is crucial to enhance the capability of the Observatory to estimate the mass of the cosmic rays on an event-by-event basis. However, with the current design of the SD, it is difficult to straightforwardly separate the contributions of muons to the SD time traces from those of photons, electrons and positrons. In this paper, we present a method aimed at extracting the muon component of the time traces registered with each individual detector of the SD using Recurrent Neural Networks. We derive the performances of the method by training the neural network on simulations, in which the muon and the electromagnetic components of the traces are known. We conclude this work showing the performance of this method on experimental data of the Pierre Auger Observatory. We find that our predictions agree with the parameterizations obtained by the AGASA collaboration to describe the lateral distributions of the electromagnetic and muonic components of extensive air showers.
△ Less
Submitted 1 August, 2021; v1 submitted 22 March, 2021;
originally announced March 2021.
-
Measurement of the fluctuations in the number of muons in extensive air showers with the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
J. M. Albury,
I. Allekotte,
A. Almela,
J. Alvarez-Muñiz,
R. Alves Batista,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
P. R. Araújo Ferreira,
H. Asorey,
P. Assis,
G. Avila,
A. M. Badescu,
A. Bakalova,
A. Balaceanu,
F. Barbato,
R. J. Barreira Luz,
K. H. Becker,
J. A. Bellido
, et al. (343 additional authors not shown)
Abstract:
We present the first measurement of the fluctuations in the number of muons in extensive air showers produced by ultrahigh energy cosmic rays. We find that the measured fluctuations are in good agreement with predictions from air shower simulations. This observation provides new insights into the origin of the previously reported deficit of muons in air shower simulations and constrains models of…
▽ More
We present the first measurement of the fluctuations in the number of muons in extensive air showers produced by ultrahigh energy cosmic rays. We find that the measured fluctuations are in good agreement with predictions from air shower simulations. This observation provides new insights into the origin of the previously reported deficit of muons in air shower simulations and constrains models of hadronic interactions at ultrahigh energies. Our measurement is compatible with the muon deficit originating from small deviations in the predictions from hadronic interaction models of particle production that accumulate as the showers develop.
△ Less
Submitted 27 April, 2021; v1 submitted 15 February, 2021;
originally announced February 2021.
-
Design and implementation of the AMIGA embedded system for data acquisition
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
J. M. Albury,
I. Allekotte,
A. Almela,
J. Alvarez-Muñiz,
R. Alves Batista,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
P. R. Araújo Ferreira,
J. C. Arteaga Velázquez,
H. Asorey,
P. Assis,
G. Avila,
A. M. Badescu,
A. Bakalova,
A. Balaceanu,
F. Barbato,
R. J. Barreira Luz,
K. H. Becker
, et al. (361 additional authors not shown)
Abstract:
The Auger Muon Infill Ground Array (AMIGA) is part of the AugerPrime upgrade of the Pierre Auger Observatory. It consists of particle counters buried 2.3 m underground next to the water-Cherenkov stations that form the 23.5 km$^2$ large infilled array. The reduced distance between detectors in this denser area allows the lowering of the energy threshold for primary cosmic ray reconstruction down t…
▽ More
The Auger Muon Infill Ground Array (AMIGA) is part of the AugerPrime upgrade of the Pierre Auger Observatory. It consists of particle counters buried 2.3 m underground next to the water-Cherenkov stations that form the 23.5 km$^2$ large infilled array. The reduced distance between detectors in this denser area allows the lowering of the energy threshold for primary cosmic ray reconstruction down to about 10$^{17}$ eV. At the depth of 2.3 m the electromagnetic component of cosmic ray showers is almost entirely absorbed so that the buried scintillators provide an independent and direct measurement of the air showers muon content. This work describes the design and implementation of the AMIGA embedded system, which provides centralized control, data acquisition and environment monitoring to its detectors. The presented system was firstly tested in the engineering array phase ended in 2017, and lately selected as the final design to be installed in all new detectors of the production phase. The system was proven to be robust and reliable and has worked in a stable manner since its first deployment.
△ Less
Submitted 20 July, 2021; v1 submitted 27 January, 2021;
originally announced January 2021.
-
The FRAM robotic telescope for atmospheric monitoring at the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
J. M. Albury,
I. Allekotte,
A. Almela,
J. Alvarez-Muñiz,
R. Alves Batista,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
P. R. Araújo Ferreira,
J. C. Arteaga Velázquez,
H. Asorey,
P. Assis,
G. Avila,
A. M. Badescu,
A. Bakalova,
A. Balaceanu,
F. Barbato,
R. J. Barreira Luz,
K. H. Becker
, et al. (355 additional authors not shown)
Abstract:
FRAM (F/Photometric Robotic Atmospheric Monitor) is a robotic telescope operated at the Pierre Auger Observatory in Argentina for the purposes of atmospheric monitoring using stellar photometry. As a passive system which does not produce any light that could interfere with the observations of the fluorescence telescopes of the observatory, it complements the active monitoring systems that use lase…
▽ More
FRAM (F/Photometric Robotic Atmospheric Monitor) is a robotic telescope operated at the Pierre Auger Observatory in Argentina for the purposes of atmospheric monitoring using stellar photometry. As a passive system which does not produce any light that could interfere with the observations of the fluorescence telescopes of the observatory, it complements the active monitoring systems that use lasers. We discuss the applications of stellar photometry for atmospheric monitoring at optical observatories in general and the particular modes of operation employed by the Auger FRAM. We describe in detail the technical aspects of FRAM, the hardware and software requirements for a successful operation of a robotic telescope for such a purpose and their implementation within the FRAM system.
△ Less
Submitted 26 July, 2021; v1 submitted 27 January, 2021;
originally announced January 2021.
-
Magnetic-buoyancy-induced mixing in AGB Stars: a theoretical explanation of the non-universal [Y/Mg]-age relation
Authors:
Magrini L.,
Vescovi D.,
Casali G.,
Cristallo S.,
Viscasillas Vazquez C.,
Cescutti G.,
Spina L.,
Van Der Swaelmen M.,
Randich S
Abstract:
The use of abundance ratios involving Y, or other slow-neutron capture elements, are routinely used to infer stellar ages.Aims.We aim to explain the observed [Y/H] and [Y/Mg] abundance ratios of star clusters located in the inner disc with a new prescription for mixing in Asymptotic Giant Branch (AGB) stars. In a Galactic chemical evolution model, we adopt a new set of AGB stellar yields in which…
▽ More
The use of abundance ratios involving Y, or other slow-neutron capture elements, are routinely used to infer stellar ages.Aims.We aim to explain the observed [Y/H] and [Y/Mg] abundance ratios of star clusters located in the inner disc with a new prescription for mixing in Asymptotic Giant Branch (AGB) stars. In a Galactic chemical evolution model, we adopt a new set of AGB stellar yields in which magnetic mixing is included. We compare the results of the model with a sample of abundances and ages of open clusters located at different Galactocentric distances. The magnetic mixing causes a less efficient production of Y at high metallicity. A non-negligible fraction of stars with super-solar metallicity is produced in the inner disc, and their Y abundances are affected by the reduced yields. The results of the new AGB model qualitatively reproduce the observed trends for both [Y/H] and [Y/Mg] vs age at different Galactocetric distances. Our results confirm from a theoretical point of view that the relationship between [Y/Mg] and stellar age cannot be universal, i.e., the same in every part of the Galaxy. It has a strong dependence on the star formation rate, on the s-process yields and their relation with metallicity, and thus it varies across the Galactic disc.
△ Less
Submitted 12 January, 2021;
originally announced January 2021.
-
Deep-Learning based Reconstruction of the Shower Maximum $X_{\mathrm{max}}$ using the Water-Cherenkov Detectors of the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
J. M. Albury,
I. Allekotte,
A. Almela,
J. Alvarez-Muñiz,
R. Alves Batista,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
P. R. Araújo Ferreira,
J. C. Arteaga Velázquez,
H. Asorey,
P. Assis,
G. Avila,
A. M. Badescu,
A. Bakalova,
A. Balaceanu,
F. Barbato,
R. J. Barreira Luz,
K. H. Becker
, et al. (348 additional authors not shown)
Abstract:
The atmospheric depth of the air shower maximum $X_{\mathrm{max}}$ is an observable commonly used for the determination of the nuclear mass composition of ultra-high energy cosmic rays. Direct measurements of $X_{\mathrm{max}}$ are performed using observations of the longitudinal shower development with fluorescence telescopes. At the same time, several methods have been proposed for an indirect e…
▽ More
The atmospheric depth of the air shower maximum $X_{\mathrm{max}}$ is an observable commonly used for the determination of the nuclear mass composition of ultra-high energy cosmic rays. Direct measurements of $X_{\mathrm{max}}$ are performed using observations of the longitudinal shower development with fluorescence telescopes. At the same time, several methods have been proposed for an indirect estimation of $X_{\mathrm{max}}$ from the characteristics of the shower particles registered with surface detector arrays. In this paper, we present a deep neural network (DNN) for the estimation of $X_{\mathrm{max}}$. The reconstruction relies on the signals induced by shower particles in the ground based water-Cherenkov detectors of the Pierre Auger Observatory. The network architecture features recurrent long short-term memory layers to process the temporal structure of signals and hexagonal convolutions to exploit the symmetry of the surface detector array. We evaluate the performance of the network using air showers simulated with three different hadronic interaction models. Thereafter, we account for long-term detector effects and calibrate the reconstructed $X_{\mathrm{max}}$ using fluorescence measurements. Finally, we show that the event-by-event resolution in the reconstruction of the shower maximum improves with increasing shower energy and reaches less than $25~\mathrm{g/cm^{2}}$ at energies above $2\times 10^{19}~\mathrm{eV}$.
△ Less
Submitted 27 July, 2021; v1 submitted 8 January, 2021;
originally announced January 2021.
-
Calibration of the underground muon detector of the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
J. M. Albury,
I. Allekotte,
A. Almela,
J. Alvarez-Muñiz,
R. Alves Batista,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
P. R. Araújo Ferreira,
J. C. Arteaga Velázquez,
H. Asorey,
P. Assis,
G. Avila,
A. M. Badescu,
A. Bakalova,
A. Balaceanu,
F. Barbato,
R. J. Barreira Luz,
K. H. Becker
, et al. (348 additional authors not shown)
Abstract:
To obtain direct measurements of the muon content of extensive air showers with energy above $10^{16.5}$ eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 $\mathrm{m^2}$-modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of b…
▽ More
To obtain direct measurements of the muon content of extensive air showers with energy above $10^{16.5}$ eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 $\mathrm{m^2}$-modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m$^2$ close to the intersection of the shower axis with the ground to much less than one per m$^2$ when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.
△ Less
Submitted 14 April, 2021; v1 submitted 14 December, 2020;
originally announced December 2020.
-
Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
J. M. Albury,
I. Allekotte,
A. Almela,
J. Alvarez-Muñiz,
R. Alves Batista,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
P. R. Araújo Ferreira,
H. Asorey,
P. Assis,
G. Avila,
A. M. Badescu,
A. Bakalova,
A. Balaceanu,
F. Barbato,
R. J. Barreira Luz,
K. H. Becker,
J. A. Bellido
, et al. (335 additional authors not shown)
Abstract:
AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each det…
▽ More
AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each detector is composed of three scintillation modules, with 10 m$^2$ detection area per module, buried at 2.3 m depth, resulting in a total detection area of 30 m$^2$. Silicon photomultiplier sensors (SiPM) measure the amount of scintillation light generated by charged particles traversing the modules. In this paper, the design of the front-end electronics to process the signals of those SiPMs and test results from the laboratory and from the Pierre Auger Observatory are described. Compared to our previous prototype, the new electronics shows a higher performance, higher efficiency and lower power consumption, and it has a new acquisition system with increased dynamic range that allows measurements closer to the shower core. The new acquisition system is based on the measurement of the total charge signal that the muonic component of the cosmic ray shower generates in the detector.
△ Less
Submitted 25 January, 2021; v1 submitted 12 November, 2020;
originally announced November 2020.