-
The MAJORANA DEMONSTRATOR Readout Electronics System
Authors:
N. Abgrall,
M. Amman,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
P. J. Barton,
F. E. Bertrand,
K. H. Bhimani,
B. Bos,
A. W. Bradley,
T. H. Burritt,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
R. J. Cooper,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko
, et al. (54 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper prov…
▽ More
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the MAJORANA DEMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.
△ Less
Submitted 23 February, 2022; v1 submitted 17 November, 2021;
originally announced November 2021.
-
Signatures of muonic activation in the Majorana Demonstrator
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
T. R. Edwards,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (33 additional authors not shown)
Abstract:
Experiments searching for very rare processes such as neutrinoless double-beta decay require a detailed understanding of all sources of background. Signals from radioactive impurities present in construction and detector materials can be suppressed using a number of well-understood techniques. Background from in-situ cosmogenic interactions can be reduced by siting an experiment deep underground.…
▽ More
Experiments searching for very rare processes such as neutrinoless double-beta decay require a detailed understanding of all sources of background. Signals from radioactive impurities present in construction and detector materials can be suppressed using a number of well-understood techniques. Background from in-situ cosmogenic interactions can be reduced by siting an experiment deep underground. However, the next generation of such experiments have unprecedented sensitivity goals of 10$^{28}$ years half-life with background rates of 10$^{-5}$cts/(keV kg yr) in the region of interest. To achieve these goals, the remaining cosmogenic background must be well understood. In the work presented here, Majorana Demonstrator data is used to search for decay signatures of meta-stable germanium isotopes. Contributions to the region of interest in energy and time are estimated using simulations, and compared to Demonstrator data. Correlated time-delayed signals are used to identify decay signatures of isotopes produced in the germanium detectors. A good agreement between expected and measured rate is found and different simulation frameworks are used to estimate the uncertainties of the predictions. The simulation campaign is then extended to characterize the background for the LEGEND experiment, a proposed tonne-scale effort searching for neutrinoless double-beta decay in $^{76}$Ge.
△ Less
Submitted 27 October, 2021;
originally announced October 2021.
-
The Majorana Demonstrator's Search for Double-Beta Decay of $^{76}$Ge to Excited States of $^{76}$Se
Authors:
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
T. R. Edwards,
D. W. Edwins,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (38 additional authors not shown)
Abstract:
The Majorana Demonstrator is a neutrinoless double-beta decay search consisting of a low-background modular array of high-purity germanium detectors, $\sim2/3$ of which are enriched to 88\% in $^{76}$Ge. The experiment is also searching for double-beta decay of $^{76}$Ge to excited states (e.s.) in $^{76}$Se. $^{76}$Ge can decay into three daughter states of $^{76}$Se, with clear event signatures…
▽ More
The Majorana Demonstrator is a neutrinoless double-beta decay search consisting of a low-background modular array of high-purity germanium detectors, $\sim2/3$ of which are enriched to 88\% in $^{76}$Ge. The experiment is also searching for double-beta decay of $^{76}$Ge to excited states (e.s.) in $^{76}$Se. $^{76}$Ge can decay into three daughter states of $^{76}$Se, with clear event signatures consisting of a $ββ$-decay followed by the prompt emission of one or two $γ$-rays. This results with high probability in multi-detector coincidences. The granularity of the Demonstrator detector array enables powerful discrimination of this event signature from backgrounds. Using 41.9~kg-y of isotopic exposure, the Demonstrator has set world leading limits for each e.s.\ decay of $^{76}$Ge, with 90\% CL lower half-life limits in the range of $(0.75-4.0)\times10^{24}$~y. In particular, for the $2ν$ transition to the first $0^+$ e.s.\ of $^{76}$Se, a lower half-life limit of $7.5\times10^{23}$~y at 90\% CL was achieved.
△ Less
Submitted 24 February, 2021; v1 submitted 13 August, 2020;
originally announced August 2020.
-
$α$-event Characterization and Rejection in Point-Contact HPGe Detectors
Authors:
The MAJORANA Collaboration,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
E. Blalock,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
T. R. Edwards,
D. W. Edwins,
Yu. Efremenko,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (40 additional authors not shown)
Abstract:
P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector's response to $α$ particles incident on the sensitive passivated and p+ surfaces, a previously poorly-understood source of background. The detector studied is identical…
▽ More
P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector's response to $α$ particles incident on the sensitive passivated and p+ surfaces, a previously poorly-understood source of background. The detector studied is identical to those in the MAJORANA DEMONSTRATOR experiment, a search for neutrinoless double-beta decay ($0νββ$) in $^{76}$Ge. $α$ decays on most of the passivated surface exhibit significant energy loss due to charge trapping, with waveforms exhibiting a delayed charge recovery (DCR) signature caused by the slow collection of a fraction of the trapped charge. The DCR is found to be complementary to existing methods of $α$ identification, reliably identifying $α$ background events on the passivated surface of the detector. We demonstrate effective rejection of all surface $α$ events (to within statistical uncertainty) with a loss of only 0.2% of bulk events by combining the DCR discriminator with previously-used methods. The DCR discriminator has been used to reduce the background rate in the $0νββ$ region of interest window by an order of magnitude in the MAJORANA DEMONSTRATOR, and will be used in the upcoming LEGEND-200 experiment.
△ Less
Submitted 14 March, 2022; v1 submitted 23 June, 2020;
originally announced June 2020.
-
ADC Nonlinearity Correction for the MAJORANA DEMONSTRATOR
Authors:
N. Abgrall,
J. M. Allmond,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
C. M. Campbell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
H. L. Crawford,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss
, et al. (42 additional authors not shown)
Abstract:
Imperfections in analog-to-digital conversion (ADC) cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the Majorana Demonstrator 76Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC…
▽ More
Imperfections in analog-to-digital conversion (ADC) cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the Majorana Demonstrator 76Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC nonlinearites. A simple measurement protocol was developed that did not require sophisticated equipment or lengthy data taking campaigns. A slope-dependent hysteresis was observed and characterized. A correction applied to digitized waveforms prior to signal processing reduced the differential and integral nonlinearites by an order of magnitude, eliminating these as dominant contributions to the systematic energy uncertainty at the double-beta decay Q value.
△ Less
Submitted 24 March, 2021; v1 submitted 4 March, 2020;
originally announced March 2020.
-
A Low Energy Rare Event Search with the Majorana Demonstrator
Authors:
MAJORANA Collaboration,
C. Wiseman,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (37 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is sensitive to rare events near its energy threshold, including bosonic dark matter, solar axions, and lightly ionizing particles. In this analysis, a novel training set of low energy small-angle Compton scatter events is used to determine the efficiency of pulse shape analysis cuts, and we present updated bosonic dark matter and solar axion results from an 11.17 kg-y da…
▽ More
The MAJORANA DEMONSTRATOR is sensitive to rare events near its energy threshold, including bosonic dark matter, solar axions, and lightly ionizing particles. In this analysis, a novel training set of low energy small-angle Compton scatter events is used to determine the efficiency of pulse shape analysis cuts, and we present updated bosonic dark matter and solar axion results from an 11.17 kg-y dataset using a 5 keV analysis threshold.
△ Less
Submitted 12 December, 2019;
originally announced December 2019.
-
Results of the MAJORANA DEMONSTRATOR's Search for Double-Beta Decay of $^{76}$Ge to Excited States of $^{76}$Se
Authors:
I. S. Guinn,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P-H. Chu,
M. L. Clark,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko
, et al. (35 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is searching for double-beta decay of $^{76}$Ge to excited states (E.S.) in $^{76}$Se using a modular array of high purity Germanium detectors. $^{76}$Ge can decay into three E.S.s of $^{76}$Se. The E.S. decays have a clear event signature consisting of a $ββ$-decay with the prompt emission of one or two $γ$-rays, resulting in with high probability in a multi-site event.…
▽ More
The MAJORANA DEMONSTRATOR is searching for double-beta decay of $^{76}$Ge to excited states (E.S.) in $^{76}$Se using a modular array of high purity Germanium detectors. $^{76}$Ge can decay into three E.S.s of $^{76}$Se. The E.S. decays have a clear event signature consisting of a $ββ$-decay with the prompt emission of one or two $γ$-rays, resulting in with high probability in a multi-site event. The granularity of the DEMONSTRATOR detector array enables powerful discrimination of this event signature from backgrounds. Using 21.3 kg-y of isotopic exposure, the DEMONSTRATOR has set world leading limits for each E.S. decay, with 90% CL lower half-life limits in the range of $(0.56-2.1)\cdot10^{24}$ y. In particular, for the $2ν$ transition to the first $0^+$ E.S. of $^{76}$Se, a lower half-life limit of $0.68\cdot10^{24}$ at 90% CL was achieved.
△ Less
Submitted 11 December, 2019;
originally announced December 2019.
-
A Search for Neutrinoless Double-Beta Decay in $^{76}$Ge with 26 kg-yr of Exposure from the MAJORANA DEMONSTRATOR
Authors:
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
V. Basu,
F. E. Bertrand,
B. Bos,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (39 additional authors not shown)
Abstract:
The MAJORANA Collaboration is operating an array of high purity Ge detectors to search for the neutrinoless double-beta decay of $^{76}$Ge. The MAJORANA DEMONSTRATOR consists of 44.1 kg of Ge detectors (29.7 kg enriched to 88% in $^{76}$Ge) split between two modules constructed from ultra-clean materials. Both modules are contained in a low-background shield at the Sanford Underground Research Fac…
▽ More
The MAJORANA Collaboration is operating an array of high purity Ge detectors to search for the neutrinoless double-beta decay of $^{76}$Ge. The MAJORANA DEMONSTRATOR consists of 44.1 kg of Ge detectors (29.7 kg enriched to 88% in $^{76}$Ge) split between two modules constructed from ultra-clean materials. Both modules are contained in a low-background shield at the Sanford Underground Research Facility in Lead, South Dakota. We present updated results on the search for neutrinoless double-beta decay in $^{76}$Ge with $26.0\pm0.5$ kg-yr of enriched exposure. With the DEMONSTRATOR's unprecedented energy resolution of 2.53 keV FWHM at $Q_{ββ}$, we observe one event in the region of interest with 0.65 events expected from the estimated background, resulting in a lower limit on the $^{76}$Ge neutrinoless double-beta decay half-life of $2.7\times10^{25}$ yr (90% CL) with a median sensitivity of $4.8\times10^{25}$ yr (90% CL). Depending on the matrix elements used, a 90% CL upper limit on the effective Majorana neutrino mass in the range of 200-433 meV is obtained. The measured background in the low-background configurations is $11.9\pm2.0$ counts/(FWHM t yr).
△ Less
Submitted 6 February, 2019;
originally announced February 2019.
-
Multi-site event discrimination for the MAJORANA DEMONSTRATOR
Authors:
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
B. Bos,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
C. R. Haufe,
R. J. Hegedus,
L. Hehn
, et al. (38 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is searching for neutrinoless double-beta decay in 76Ge using arrays of point-contact germanium detectors operating at the Sanford Underground Research Facility. Background results in the neutrinoless double-beta decay region of interest from data taken during construction, commissioning, and the start of full operations have been recently published. A pulse shape analysi…
▽ More
The MAJORANA DEMONSTRATOR is searching for neutrinoless double-beta decay in 76Ge using arrays of point-contact germanium detectors operating at the Sanford Underground Research Facility. Background results in the neutrinoless double-beta decay region of interest from data taken during construction, commissioning, and the start of full operations have been recently published. A pulse shape analysis cut applied to achieve this result, named AvsE, is described in this paper. This cut is developed to remove events whose waveforms are typical of multi-site energy deposits while retaining (90 +/- 3.5)% of single-site events. This pulse shape discrimination is based on the relationship between the maximum current and energy, and tuned using 228Th calibration source data. The efficiency uncertainty accounts for variation across detectors, energy, and time, as well as for the position distribution difference between calibration and $0νββ$ events, established using simulations.
△ Less
Submitted 16 January, 2019;
originally announced January 2019.
-
Recent results from the MAJORANA DEMONSTRATOR
Authors:
J. Myslik,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
B. Bos,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (43 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decay in $^{76}$Ge and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modules of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, operating at the 4850' level of the Sanford Underground Research Facility in Lead, S…
▽ More
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decay in $^{76}$Ge and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modules of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, operating at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Commissioning of the experiment began in June 2015, followed by data production with the full detector array in August 2016. The ultra-low background and record energy resolution achieved by the MAJORANA DEMONSTRATOR enable a sensitive neutrinoless double-beta decay search, as well as additional searches for physics beyond the Standard Model. I will discuss the design elements that enable these searches, along with the latest results, focusing on the neutrinoless double-beta decay search. I will also discuss the current status and the future plans of the MAJORANA DEMONSTRATOR, as well as the plans for a future tonne-scale $^{76}$Ge experiment.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
Search for Tri-Nucleon Decay in the Majorana Demonstrator
Authors:
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
B. Bos,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (41 additional authors not shown)
Abstract:
The Majorana Demonstrator is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. We present the first limits for tri-nucleon decay-specific modes and invisible d…
▽ More
The Majorana Demonstrator is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. We present the first limits for tri-nucleon decay-specific modes and invisible decay modes for Ge isotopes. We find a half-life limit of $4.9 \times 10^{25}$ yr for the decay $^{76}{\rm Ge(ppn)} \to {}^{73}{\rm Zn}\ e^+π^+$ and $4.7\times10^{25}$ yr for the decay $^{76}{\rm Ge(ppp)} \to ^{73}{\rm Cu}\ e^+π^+π^+$. The half-life limit for the invisible tri-proton decay mode of $^{76}$Ge was found to be $7.5\times10^{24}$ yr.
△ Less
Submitted 26 March, 2019; v1 submitted 3 December, 2018;
originally announced December 2018.
-
Recent Results from the Majorana Demonstrator
Authors:
T Gilliss,
S I Alvis,
I J Arnquist,
F T Avignone III,
A S Barabash,
C J Barton,
F E Bertrand,
T Bode,
V Brudanin,
M Busch,
M Buuck,
T S Caldwell,
Y-D Chan,
C D Christofferson,
P -H Chu,
C Cuesta,
J A Detwiler,
C Dunagan,
Yu Efremenko,
H Ejiri,
S R Elliott,
G K Giovanetti,
M P Green,
J Gruszko,
I S Guinn
, et al. (43 additional authors not shown)
Abstract:
The MAJORANA Collaboration has completed construction and is now operating an array of high purity Ge detectors searching for neutrinoless double-beta decay ($0νββ$) in $^{76}$Ge. The array, known as the MAJORANA DEMONSTRATOR, is comprised of 44 kg of Ge detectors (30 kg enriched to 88% in $^{76}$Ge) installed in an ultra-low background compact shield at the Sanford Underground Research Facility i…
▽ More
The MAJORANA Collaboration has completed construction and is now operating an array of high purity Ge detectors searching for neutrinoless double-beta decay ($0νββ$) in $^{76}$Ge. The array, known as the MAJORANA DEMONSTRATOR, is comprised of 44 kg of Ge detectors (30 kg enriched to 88% in $^{76}$Ge) installed in an ultra-low background compact shield at the Sanford Underground Research Facility in Lead, South Dakota. The primary goal of the DEMONSTRATOR is to establish a low-background design that can be scaled to a next-generation tonne-scale experiment. This work reports initial background levels in the $0νββ$ region of interest. Also presented are recent physics results leveraging P-type point-contact detectors with sub-keV energy thresholds to search for physics beyond the Standard Model; first results from searches for bosonic dark matter, solar axions, Pauli exclusion principle violation, and electron decay have been published. Finally, this work discusses the proposed tonne-scale $^{76}$Ge $0νββ$ LEGEND experiment.
△ Less
Submitted 4 April, 2018;
originally announced April 2018.
-
The Majorana Demonstrator Status and Preliminary Results
Authors:
C. -H. Yu,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y. -D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. Green,
J. Gruszko
, et al. (41 additional authors not shown)
Abstract:
The Majorana Collaboration is using an array of high-purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. Searches for neutrinoless double-beta decay are understood to be the only viable experimental method for testing the Majorana nature of the neutrino. Observation of this decay would imply violation of lepton number, that neutrinos are Majorana in nature, and provide inform…
▽ More
The Majorana Collaboration is using an array of high-purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. Searches for neutrinoless double-beta decay are understood to be the only viable experimental method for testing the Majorana nature of the neutrino. Observation of this decay would imply violation of lepton number, that neutrinos are Majorana in nature, and provide information on the neutrino mass. The Majorana Demonstrator comprises 44.1 kg of p-type point-contact Ge detectors (29.7 kg enriched in 76Ge) surrounded by a low-background shield system. The experiment achieved a high efficiency of converting raw Ge material to detectors and an unprecedented detector energy resolution of 2.5 keV FWHM at Q$_{ββ}$. The Majorana collaboration began taking physics data in 2016. This paper summarizes key construction aspects of the Demonstrator and shows preliminary results from initial data.
△ Less
Submitted 29 March, 2018;
originally announced March 2018.
-
First Limit on the Direct Detection of Lightly Ionizing Particles for Electric Charge as Low as $e$/1000 with the \textsc{Majorana Demonstrator}
Authors:
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe
, et al. (39 additional authors not shown)
Abstract:
The \textsc{Majorana Demonstrator} is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. Free, relativistic, lightly-ionizing particles with electrical charges…
▽ More
The \textsc{Majorana Demonstrator} is an ultra low-background experiment searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. Free, relativistic, lightly-ionizing particles with electrical charges less than $e$ are forbidden by the standard model but predicted by some of its extensions. If such particles exist, they might be detected in the \textsc{Majorana Demonstrator} by searching for multiple- detector events with individual-detector energy depositions down to 1 keV. This search is background free and no candidate events have been found in 285 days of data taking. New direct-detection limits are set for the flux of lightly ionizing particles for charges as low as $e$/1000.
△ Less
Submitted 29 May, 2018; v1 submitted 30 January, 2018;
originally announced January 2018.
-
Low Background Materials and Fabrication Techniques for Cables and Connectors in the Majorana Demonstrator
Authors:
M. Busch,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (45 additional authors not shown)
Abstract:
The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus Ge-76. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a tonne scale Ge-76-based search (the LEGEND collaboration). In the DEMONSTRATOR, germanium detectors operate in an ultra-pure vacuum cryostat at 80 K. One…
▽ More
The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus Ge-76. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a tonne scale Ge-76-based search (the LEGEND collaboration). In the DEMONSTRATOR, germanium detectors operate in an ultra-pure vacuum cryostat at 80 K. One special challenge of an ultra-pure environment is to develop reliable cables, connectors, and electronics that do not significantly contribute to the radioactive background of the experiment. This paper highlights the experimental requirements and how these requirements were met for the MAJORANA DEMONSTRATOR, including plans to upgrade the wiring for higher reliability in the summer of 2018. Also described are requirements for LEGEND R&D efforts underway to meet these additional requirements.
△ Less
Submitted 13 December, 2017;
originally announced December 2017.
-
Design improvements to cables and connectors in the Majorana Demonstrator
Authors:
C. R. Haufe,
A. L. Reine,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y. -D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss
, et al. (46 additional authors not shown)
Abstract:
The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Researc…
▽ More
The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radiopurity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. We will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.
△ Less
Submitted 9 December, 2017;
originally announced December 2017.
-
Initial Results from the Majorana Demonstrator
Authors:
T. S. Caldwell,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
B. Bos,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti
, et al. (47 additional authors not shown)
Abstract:
The MAJORANA Collaboration has assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge with the goal of establishing the required background and scalability of a Ge-based next-generation ton-scale experiment. The MAJORANA DEMONSTRATOR consists of 44 kg of high-purity Ge (HPGe) detectors (30 kg enriched in $^{76}$Ge) with a low-noise p-type point con…
▽ More
The MAJORANA Collaboration has assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge with the goal of establishing the required background and scalability of a Ge-based next-generation ton-scale experiment. The MAJORANA DEMONSTRATOR consists of 44 kg of high-purity Ge (HPGe) detectors (30 kg enriched in $^{76}$Ge) with a low-noise p-type point contact (PPC) geometry. The detectors are split between two modules which are contained in a single lead and high-purity copper shield at the Sanford Underground Research Facility in Lead, South Dakota. Following a commissioning run that started in June 2015, the full detector array has been acquiring data since August 2016. We will discuss the status of the MAJORANA DEMONSTRATOR and initial results from the first physics run; including current background estimates, exotic low-energy physics searches, projections on the physics reach of the DEMONSTRATOR, and implications for a ton-scale Ge-based neutrinoless double-beta decay search.
△ Less
Submitted 29 November, 2017;
originally announced November 2017.
-
Data quality assurance for the MAJORANA DEMONSTRATOR
Authors:
J. Myslik,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P-H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti
, et al. (46 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, located at the 4850' level of the Sanford Underground Research Facility i…
▽ More
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and $^{76}$Ge-enriched germanium detectors totalling 44.1 kg, located at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Any neutrinoless double-beta decay search requires a thorough understanding of the background and the signal energy spectra. The various techniques employed to ensure the integrity of the measured spectra are discussed. Data collection is monitored with a thorough set of checks, and subsequent careful analysis is performed to qualify the data for higher level physics analysis. Instrumental background events are tagged for removal, and problematic channels are removed from consideration as necessary.
△ Less
Submitted 28 November, 2017;
originally announced November 2017.
-
Contamination Control and Assay Results for the Majorana Demonstrator Ultra Clean Components
Authors:
C. D. Christofferson,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (45 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The DEMONSTRATOR has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operatin…
▽ More
The MAJORANA DEMONSTRATOR is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The DEMONSTRATOR has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. This article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.
△ Less
Submitted 28 November, 2017;
originally announced November 2017.
-
Progress Toward A $2νββ$ Measurement For The Majorana Demonstrator
Authors:
T Gilliss,
N Abgrall,
S I Alvis,
I J Arnquist,
F T Avignone III,
A S Barabash,
C J Barton,
F E Bertrand,
T Bode,
A W Bradley,
V Brudanin,
M Busch,
M Buuck,
T S Caldwell,
Y-D Chan,
C D Christofferson,
P -H Chu,
C Cuesta,
J A Detwiler,
C Dunagan,
Yu Efremenko,
H Ejiri,
S R Elliott,
G K Giovanetti,
M P Green
, et al. (46 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is a $^{76}$Ge-based neutrinoless double-beta decay ($0νββ$) experiment. Staged at the 4850 ft level of the Sanford Underground Research Facility, the DEMONSTRATOR operates an array of high-purity p-type point contact Ge detectors deployed within a graded passive shield and an active muon veto system. The present work concerns the two-neutrino double-beta decay mode (…
▽ More
The MAJORANA DEMONSTRATOR is a $^{76}$Ge-based neutrinoless double-beta decay ($0νββ$) experiment. Staged at the 4850 ft level of the Sanford Underground Research Facility, the DEMONSTRATOR operates an array of high-purity p-type point contact Ge detectors deployed within a graded passive shield and an active muon veto system. The present work concerns the two-neutrino double-beta decay mode ($2νββ$) of $^{76}$Ge. For Ge detectors, having superior energy resolution (0.1%), this mode poses negligible background to the $0νββ$ mode, even for a ton-scale experiment. However, the measurement of the $2νββ$ mode allows for careful systematics checks of active detector mass, enrichment fraction, and pulse shape discrimination cuts related to both the $0νββ$ and $2νββ$ decay modes. A precision measurement of the $2νββ$ shape also allows searches for spectral distortions, possibly indicative of new physics, including $0νββχ$. Work is underway to construct a full experimental background model enabling a Bayesian fit to the measured energy spectrum and extraction of a precise $2νββ$ spectrum and half-life.
△ Less
Submitted 20 November, 2017; v1 submitted 15 November, 2017;
originally announced November 2017.
-
Spectral analysis for the Majorana Demonstrator experiment
Authors:
L. Hehn,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P-H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti
, et al. (46 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and $^{76}\textrm{Ge}$-enriched germanium detectors totaling 44.1 kg (29.7 kg enriched detectors), located at the 4850' level of the Sanf…
▽ More
The MAJORANA DEMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and $^{76}\textrm{Ge}$-enriched germanium detectors totaling 44.1 kg (29.7 kg enriched detectors), located at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Data taken with this setup since summer 2015 at different construction stages of the experiment show a clear reduction of the observed background index around the ROI for $0νββ$-decay search due to improvements in shielding. We discuss the statistical approaches to search for a $0νββ$-signal and derive the physics sensitivity for an expected exposure of $10\,\textrm{kg}{\cdot}\textrm{y}$ from enriched detectors using a profile likelihood based hypothesis test in combination with toy Monte Carlo data.
△ Less
Submitted 8 November, 2017;
originally announced November 2017.
-
Search for Zero-Neutrino Double Beta Decay in 76Ge with the Majorana Demonstrator
Authors:
C. E. Aalseth,
N. Abgrall,
E. Aguayo,
S. I. Alvis,
M. Amman,
I. J. Arnquist,
F. T. Avignone III,
H. O. Back,
A. S. Barabash,
P. S. Barbeau,
C. J. Barton,
P. J. Barton,
F. E. Bertrand,
T. Bode,
B. Bos,
M. Boswell,
R. L. Brodzinski,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
A. S. Caldwell,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson
, et al. (104 additional authors not shown)
Abstract:
The \MJ\ Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The \MJ\ \DEM\ comprises 44.1~kg of Ge detectors (29.7 kg enriched in $^{76}$Ge) split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construct…
▽ More
The \MJ\ Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The \MJ\ \DEM\ comprises 44.1~kg of Ge detectors (29.7 kg enriched in $^{76}$Ge) split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construction, commissioning, and the start of full operations. We achieve unprecedented energy resolution of 2.5 keV FWHM at \qval\ and a very low background with no observed candidate events in 10 kg yr of enriched Ge exposure, resulting in a lower limit on the half-life of $1.9\times10^{25}$ yr (90\% CL). This result constrains the effective Majorana neutrino mass to below 240 to 520 meV, depending on the matrix elements used. In our experimental configuration with the lowest background, the background is $4.0_{-2.5}^{+3.1}$ counts/(FWHM t yr).
△ Less
Submitted 26 March, 2018; v1 submitted 31 October, 2017;
originally announced October 2017.
-
The Status and Initial Results of the MAJORANA DEMONSTRATOR Experiment
Authors:
V. E. Guiseppe,
N. Abgrall,
S. I. Alvis,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
F. E. Bertrand,
T. Bode,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti
, et al. (45 additional authors not shown)
Abstract:
Neutrinoless double-beta decay searches play a major role in determining the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The MAJORANA Collaboration assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in Ge-76. The MAJORANA DEMONSTRATOR is comprised of 44.1 kg (29.7 kg enriched in Ge-76) of Ge de…
▽ More
Neutrinoless double-beta decay searches play a major role in determining the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The MAJORANA Collaboration assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in Ge-76. The MAJORANA DEMONSTRATOR is comprised of 44.1 kg (29.7 kg enriched in Ge-76) of Ge detectors divided between two modules contained in a low-background shield at the Sanford Underground Research Facility in Lead, South Dakota, USA. The initial goals of the DEMONSTRATOR are to establish the required background and scalability of a Ge-based next-generation ton-scale experiment. Following a commissioning run that started in 2015, the first detector module started low-background data production in early 2016. The second detector module was added in August 2016 to begin operation of the entire array. We discuss results of the initial physics runs, as well as the status and physics reach of the full MAJORANA DEMONSTRATOR experiment.
△ Less
Submitted 24 August, 2017;
originally announced August 2017.
-
The Processing of Enriched Germanium for the MAJORANA DEMONSTRATOR and R&D for a Possible Future Ton-Scale Ge-76 Double-Beta Decay Experiment
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
J. Caja,
M. Caja,
T. S. Caldwell,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
D. T. Dunstan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (45 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an array of point-contact Ge detectors fabricated from Ge isotopically enriched to 88% in Ge-76 to search for neutrinoless double beta decay. The processing of Ge for germanium detectors is a well-known technology. However, because of the high cost of Ge enriched in Ge-76, special procedures were required to maximize the yield of detector mass and to minimize exposure…
▽ More
The MAJORANA DEMONSTRATOR is an array of point-contact Ge detectors fabricated from Ge isotopically enriched to 88% in Ge-76 to search for neutrinoless double beta decay. The processing of Ge for germanium detectors is a well-known technology. However, because of the high cost of Ge enriched in Ge-76, special procedures were required to maximize the yield of detector mass and to minimize exposure to cosmic rays. These procedures include careful accounting for the material; shielding it to reduce cosmogenic generation of radioactive isotopes; and development of special reprocessing techniques for contaminated solid germanium, shavings, grindings, acid etchant and cutting fluids from detector fabrication. Processing procedures were developed that resulted in a total yield in detector mass of 70%. However, none of the acid-etch solution and only 50% of the cutting fluids from detector fabrication were reprocessed. Had they been processed, the projections for the recovery yield would be between 80 -- 85%. Maximizing yield is critical to justify a possible future ton-scale experiment. A process for recovery of germanium from the acid-etch solution was developed with yield of about 90%. All material was shielded or stored underground whenever possible to minimize the formation of Ge-68 by cosmic rays, which contributes background in the double-beta decay region of interest and cannot be removed by zone refinement and crystal growth. Formation of Ge-68 was reduced by a significant factor over that in natural abundance detectors not protected from cosmic rays.
△ Less
Submitted 19 July, 2017;
originally announced July 2017.
-
The Majorana Demonstrator calibration system
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
Z. Fu,
V. M. Gehman,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (42 additional authors not shown)
Abstract:
The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus $^{76}$Ge. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a 1-tonne $^{76}$Ge-based search. The ultra low-background conditions require regular calibrations to verify proper function of the detectors. Radioact…
▽ More
The MAJORANA Collaboration is searching for the neutrinoless double-beta decay of the nucleus $^{76}$Ge. The MAJORANA DEMONSTRATOR is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a 1-tonne $^{76}$Ge-based search. The ultra low-background conditions require regular calibrations to verify proper function of the detectors. Radioactive line sources can be deployed around the cryostats containing the detectors for regular energy calibrations. When measuring in low-background mode, these line sources have to be stored outside the shielding so they do not contribute to the background. The deployment and the retraction of the source are designed to be controlled by the data acquisition system and do not require any direct human interaction. In this paper, we detail the design requirements and implementation of the calibration apparatus, which provides the event rates needed to define the pulse-shape cuts and energy calibration used in the final analysis as well as data that can be compared to simulations.
△ Less
Submitted 6 February, 2017;
originally announced February 2017.
-
New limits on Bosonic Dark Matter, Solar Axions, Pauli Exclusion Principle Violation, and Electron Decay from the Majorana Demonstrator
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green,
J. Gruszko,
I. S. Guinn
, et al. (42 additional authors not shown)
Abstract:
We present new limits on exotic keV-scale physics based on 478 kg d of MAJORANA DEMONSTRATOR commissioning data. Constraints at the 90% confidence level are derived on bosonic dark matter (DM) and solar axion couplings, Pauli exclusion principle violating (PEPV) decay, and electron decay using monoenergetic peak signal-limits above our background. Our most stringent DM constraints are set for 11.8…
▽ More
We present new limits on exotic keV-scale physics based on 478 kg d of MAJORANA DEMONSTRATOR commissioning data. Constraints at the 90% confidence level are derived on bosonic dark matter (DM) and solar axion couplings, Pauli exclusion principle violating (PEPV) decay, and electron decay using monoenergetic peak signal-limits above our background. Our most stringent DM constraints are set for 11.8 keV mass particles, limiting $g_{Ae} <4.5\times 10^{-13}$ for pseudoscalars and $\frac{α'}α < 9.7\times 10^{-28}$ for vectors. We also report a 14.4 keV solar axion coupling limit of $g_{AN}^{\mathrm{eff}}\times g_{Ae}~<~3.8 \times 10^{-17}$, a $\frac{1}{2}β^2~<~8.5\times10^{-48}$ limit on the strength of PEPV electron transitions, and a lower limit on the electron lifetime of $τ_e > 1.2 \times 10^{24}\;$yr for $e^- \rightarrow$ invisible.
△ Less
Submitted 11 April, 2017; v1 submitted 2 December, 2016;
originally announced December 2016.
-
Search for Pauli Exclusion Principle Violating Atomic Transitions and Electron Decay with a P-type Point Contact Germanium Detector
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
P. S Finnerty,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (44 additional authors not shown)
Abstract:
A search for Pauli-exclusion-principle-violating K-alpha electron transitions was performed using 89.5 kg-d of data collected with a p-type point contact high-purity germanium detector operated at the Kimballton Underground Research Facility. A lower limit on the transition lifetime of 5.8x10^30 seconds at 90% C.L. was set by looking for a peak at 10.6 keV resulting from the x-ray and Auger electr…
▽ More
A search for Pauli-exclusion-principle-violating K-alpha electron transitions was performed using 89.5 kg-d of data collected with a p-type point contact high-purity germanium detector operated at the Kimballton Underground Research Facility. A lower limit on the transition lifetime of 5.8x10^30 seconds at 90% C.L. was set by looking for a peak at 10.6 keV resulting from the x-ray and Auger electrons present following the transition. A similar analysis was done to look for the decay of atomic K-shell electrons into neutrinos, resulting in a lower limit of 6.8x10^30 seconds at 90 C.L. It is estimated that the MAJORANA DEMONSTRATOR, a 44 kg array of p-type point contact detectors that will search for the neutrinoless double-beta decay of 76-Ge, could improve upon these exclusion limits by an order of magnitude after three years of operation.
△ Less
Submitted 19 October, 2016;
originally announced October 2016.
-
Delayed charge recovery discrimination of passivated surface alpha events in P-type point-contact detectors
Authors:
J. Gruszko,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Fullmer,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
M. P. Green
, et al. (43 additional authors not shown)
Abstract:
The Majorana Demonstrator searches for neutrinoless double-beta decay of $^{76}$Ge using arrays of high-purity germanium detectors. If observed, this process would demonstrate that lepton number is not a conserved quantity in nature, with implications for grand-unification and for explaining the predominance of matter over antimatter in the universe. A problematic background in such large granular…
▽ More
The Majorana Demonstrator searches for neutrinoless double-beta decay of $^{76}$Ge using arrays of high-purity germanium detectors. If observed, this process would demonstrate that lepton number is not a conserved quantity in nature, with implications for grand-unification and for explaining the predominance of matter over antimatter in the universe. A problematic background in such large granular detector arrays is posed by alpha particles. In the Majorana Demonstrator, events have been observed that are consistent with energy- degraded alphas originating on the passivated surface, leading to a potential background contribution in the region-of-interest for neutrinoless double-beta decay. However, it is also observed that when energy deposition occurs very close to the passivated surface, charges drift through the bulk onto that surface, and then drift along it with greatly reduced mobility. This leads to both a reduced prompt signal and a measurable change in slope of the tail of a recorded pulse. In this contribution we discuss the characteristics of these events and the development of a filter that can identify the occurrence of this delayed charge recovery, allowing for the efficient rejection of passivated surface alpha events in analysis.
△ Less
Submitted 7 October, 2016;
originally announced October 2016.
-
Initial Results from the MAJORANA DEMONSTRATOR
Authors:
S. R. Elliott,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
A. Fullmer,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko
, et al. (42 additional authors not shown)
Abstract:
Neutrinoless double-beta decay searches seek to determine the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The {\sc Majorana} Collaboration is assembling an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The {\sc Majorana Demonstrator} is composed of 44.8~kg (29.7 kg enriched in $^{76}$Ge)…
▽ More
Neutrinoless double-beta decay searches seek to determine the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The {\sc Majorana} Collaboration is assembling an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The {\sc Majorana Demonstrator} is composed of 44.8~kg (29.7 kg enriched in $^{76}$Ge) of Ge detectors in total, split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. The initial goals of the {\sc Demonstrator} are to establish the required background and scalability of a Ge-based, next-generation, tonne-scale experiment. Following a commissioning run that began in 2015, the first detector module started physics data production in early 2016. We will discuss initial results of the Module 1 commissioning and first physics run, as well as the status and potential physics reach of the full {\sc Majorana Demonstrator} experiment. The collaboration plans to complete the assembly of the second detector module by mid-2016 to begin full data production with the entire array.
△ Less
Submitted 4 October, 2016;
originally announced October 2016.
-
Background model for the MAJORANA DEMONSTRATOR
Authors:
C. Cuesta,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Fullmer,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko
, et al. (42 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing a system containing 44 kg of high-purity Ge (HPGe) detectors to demonstrate the feasibility and potential of a future tonne-scale experiment capable of probing the neutrino mass scale to ~15 meV. To realize this, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path forward to achieving a background rate at or below 1 count/(ROI-t-y) in the 4…
▽ More
The MAJORANA Collaboration is constructing a system containing 44 kg of high-purity Ge (HPGe) detectors to demonstrate the feasibility and potential of a future tonne-scale experiment capable of probing the neutrino mass scale to ~15 meV. To realize this, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path forward to achieving a background rate at or below 1 count/(ROI-t-y) in the 4 keV region of interest (ROI) around the Q-value at 2039 keV. This goal is pursued through a combination of a significant reduction of radioactive impurities in construction materials and analytical methods for background rejection, for example using powerful pulse shape analysis techniques profiting from the p-type point contact HPGe detectors technology. The effectiveness of these methods is assessed using simulations of the different background components whose purity levels are constrained from radioassay measurements. Preliminary background results obtained during the engineering runs of the Demonstrator are presented.
△ Less
Submitted 3 October, 2016;
originally announced October 2016.
-
The Majorana Demonstrator search for neutrinoless double beta decay
Authors:
C. Cuesta,
M. Buuck,
J. A. Detwiler,
J. Gruszko,
I. S. Guinn,
J. Leon,
R. G. H. Robertson,
N. Abgrall,
A. W. Bradley,
Y-D. Chan,
S. Mertens,
A. W. P. Poon,
K. Vetter,
I. J. Arnquist,
E. W. Hoppe,
R. T. Kouzes,
J. L. Orrell,
F. T. Avignone III,
A. S. Barabash,
S. I. Konovalov,
V. Yumatov,
F. E. Bertrand,
A. Galindo-Uribarri,
D. C. Radford,
R. L. Varner
, et al. (42 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44.8-kg (29.7 kg enriched >88% in Ge-76) to search for neutrinoless double beta decay in Ge-76. The next generation of tonnescale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA…
▽ More
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44.8-kg (29.7 kg enriched >88% in Ge-76) to search for neutrinoless double beta decay in Ge-76. The next generation of tonnescale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward to achieve a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a modular implementation to be easily scalable to the next generation experiment. First data taken with the DEMONSTRATOR are introduced here.
△ Less
Submitted 29 August, 2016; v1 submitted 25 August, 2016;
originally announced August 2016.
-
High voltage testing for the MAJORANA Demonstrator
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
P. J. Doe,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
Z. Fu,
A. Galindo-Uribarri,
G. K. Giovanetti,
J. Goett
, et al. (48 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA Demonstrator. This effect can damage the front-end electronics or mimic detector sign…
▽ More
The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA Demonstrator was characterized and the micro-discharge effects during the MAJORANA Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.
△ Less
Submitted 28 March, 2016; v1 submitted 28 March, 2016;
originally announced March 2016.
-
Muon Flux Measurements at the Davis Campus of the Sanford Underground Research Facility with the Majorana Demonstrator Veto System
Authors:
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (49 additional authors not shown)
Abstract:
We report the first measurement of the total MUON flux underground at the Davis Campus of the Sanford Underground Research Facility at the 4850 ft level. Measurements were done with the Majorana Demonstrator veto system arranged in two different configurations. The measured total flux is (5.31+/-0.17) x 10^-9 muons/s/cm^2.
We report the first measurement of the total MUON flux underground at the Davis Campus of the Sanford Underground Research Facility at the 4850 ft level. Measurements were done with the Majorana Demonstrator veto system arranged in two different configurations. The measured total flux is (5.31+/-0.17) x 10^-9 muons/s/cm^2.
△ Less
Submitted 7 September, 2016; v1 submitted 24 February, 2016;
originally announced February 2016.
-
The Majorana Demonstrator Radioassay Program
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
H. O. Back,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
J. A. Dunmore,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
P. Finnerty,
A. Galindo-Uribarri,
V. M. Gehman
, et al. (60 additional authors not shown)
Abstract:
The MAJORANA collaboration is constructing the MAJORANA DEMONSTATOR at the Sanford Underground Research Facility at the Homestake gold mine, in Lead, SD. The apparatus will use Ge detectors, enriched in isotope \nuc{76}{Ge}, to demonstrate the feasibility of a large-scale Ge detector experiment to search for neutrinoless double beta decay. The long half-life of this postulated process requires tha…
▽ More
The MAJORANA collaboration is constructing the MAJORANA DEMONSTATOR at the Sanford Underground Research Facility at the Homestake gold mine, in Lead, SD. The apparatus will use Ge detectors, enriched in isotope \nuc{76}{Ge}, to demonstrate the feasibility of a large-scale Ge detector experiment to search for neutrinoless double beta decay. The long half-life of this postulated process requires that the apparatus be extremely low in radioactive isotopes whose decays may produce backgrounds to the search. The radioassay program conducted by the collaboration to ensure that the materials comprising the apparatus are sufficiently pure is described. The resulting measurements of the radioactive-isotope contamination for a number of materials studied for use in the detector are reported.
△ Less
Submitted 22 April, 2016; v1 submitted 14 January, 2016;
originally announced January 2016.
-
Status of the MAJORANA DEMONSTRATOR
Authors:
C. Cuesta,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
C. X. Baldenegro-Barrera,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (45 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44-kg (29 kg 76Ge and 15 kg natGe) to search for neutrinoless double beta decay in Ge-76. The next generation of tonne-scale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMON…
▽ More
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44-kg (29 kg 76Ge and 15 kg natGe) to search for neutrinoless double beta decay in Ge-76. The next generation of tonne-scale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward to achieve a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a modular implementation to be easily scalable to the next generation experiment. First, the prototype module was assembled; it has been continuously taking data from July 2014 to June 2015. Second, Module 1 with more than half of the total enriched detectors and some natural detectors has been assembled and it is being commissioned. Finally, the assembly of Module 2, which will complete MAJORANA DEMONSTRATOR, is already in progress.
△ Less
Submitted 27 July, 2015;
originally announced July 2015.
-
Low Background Signal Readout Electronics for the MAJORANA DEMONSTRATOR
Authors:
I. Guinn,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
C. X. Baldenegro-Barrera,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (43 additional authors not shown)
Abstract:
The MAJORANA Collaboration will seek neutrinoless double beta decay (0nbb) in 76Ge using isotopically enriched p-type point contact (PPC) high purity Germanium (HPGe) detectors. A tonne-scale array of HPGe detectors would require background levels below 1 count/ROI-tonne-year in the 4 keV region of interest (ROI) around the 2039 keV Q-value of the decay. In order to demonstrate the feasibility of…
▽ More
The MAJORANA Collaboration will seek neutrinoless double beta decay (0nbb) in 76Ge using isotopically enriched p-type point contact (PPC) high purity Germanium (HPGe) detectors. A tonne-scale array of HPGe detectors would require background levels below 1 count/ROI-tonne-year in the 4 keV region of interest (ROI) around the 2039 keV Q-value of the decay. In order to demonstrate the feasibility of such an experiment, the MAJORANA DEMONSTRATOR, a 40 kg HPGe detector array, is being constructed with a background goal of <3 counts/ROI-tonne-year, which is expected to scale down to <1 count/ROI-tonne-year for a tonne-scale experiment. The signal readout electronics, which must be placed in close proximity to the detectors, present a challenge toward reaching this background goal. This talk will discuss the materials and design used to construct signal readout electronics with low enough backgrounds for the MAJORANA DEMONSTRATOR.
△ Less
Submitted 13 June, 2015;
originally announced June 2015.
-
Analysis techniques for background rejection at the MAJORANA DEMONSTRATOR
Authors:
C. Cuesta,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
C. X. Baldenegro-Barrera,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green,
J. Gruszko
, et al. (43 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 40-kg modular HPGe detector array to search for neutrinoless double beta decay in 76Ge. In view of the next generation of tonne-scale Ge-based 0nbb-decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path f…
▽ More
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 40-kg modular HPGe detector array to search for neutrinoless double beta decay in 76Ge. In view of the next generation of tonne-scale Ge-based 0nbb-decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path forward to achieving a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value at 2039 keV. The background rejection techniques to be applied to the data include cuts based on data reduction, pulse shape analysis, event coincidences, and time correlations. The Point Contact design of the DEMONSTRATOR 0s germanium detectors allows for significant reduction of gamma background.
△ Less
Submitted 10 June, 2015;
originally announced June 2015.
-
Low Background Signal Readout Electronics for the MAJORANA DEMONSTRATOR
Authors:
I. Guinn,
N. Abgrall,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
G. K. Giovanetti,
J. Goett,
M. P. Green,
J. Gruszko,
V. E. Guiseppe,
R. Henning,
E. W. Hoppe
, et al. (40 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is a planned 40 kg array of Germanium detectors intended to demonstrate the feasibility of constructing a tonne-scale experiment that will seek neutrinoless double beta decay ($0νββ$) in $^{76}\mathrm{Ge}$. Such an experiment would require backgrounds of less than 1 count/tonne-year in the 4 keV region of interest around the 2039 keV Q-value of the $ββ$ decay. Designing l…
▽ More
The MAJORANA DEMONSTRATOR is a planned 40 kg array of Germanium detectors intended to demonstrate the feasibility of constructing a tonne-scale experiment that will seek neutrinoless double beta decay ($0νββ$) in $^{76}\mathrm{Ge}$. Such an experiment would require backgrounds of less than 1 count/tonne-year in the 4 keV region of interest around the 2039 keV Q-value of the $ββ$ decay. Designing low-noise electronics, which must be placed in close proximity to the detectors, presents a challenge to reaching this background target. This paper will discuss the MAJORANA collaboration's solutions to some of these challenges.
△ Less
Submitted 10 February, 2015;
originally announced February 2015.
-
The Majorana Parts Tracking Database
Authors:
The Majorana Collaboration,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
V. Brudanin,
M. Busch,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
C. Cuesta,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. Esterline,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri
, et al. (67 additional authors not shown)
Abstract:
The Majorana Demonstrator is an ultra-low background physics experiment searching for the neutrinoless double beta decay of $^{76}$Ge. The Majorana Parts Tracking Database is used to record the history of components used in the construction of the Demonstrator. The tracking implementation takes a novel approach based on the schema-free database technology CouchDB. Transportation, storage, and proc…
▽ More
The Majorana Demonstrator is an ultra-low background physics experiment searching for the neutrinoless double beta decay of $^{76}$Ge. The Majorana Parts Tracking Database is used to record the history of components used in the construction of the Demonstrator. The tracking implementation takes a novel approach based on the schema-free database technology CouchDB. Transportation, storage, and processes undergone by parts such as machining or cleaning are linked to part records. Tracking parts provides a great logistics benefit and an important quality assurance reference during construction. In addition, the location history of parts provides an estimate of their exposure to cosmic radiation. A web application for data entry and a radiation exposure calculator have been developed as tools for achieving the extreme radio-purity required for this rare decay search.
△ Less
Submitted 5 February, 2015;
originally announced February 2015.
-
MAJORANA Collaboration's Experience with Germanium Detectors
Authors:
S. Mertens,
N. Abgrall,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
G. K. Giovanetti,
J. Goett,
M. P. Green,
J. Gruszko,
I. Guinn,
V. E. Guiseppe,
R. Henning
, et al. (40 additional authors not shown)
Abstract:
The goal of the \textsc{Majorana} \textsc{Demonstrator} project is to search for 0$νββ$ decay in $^{76}\mathrm{Ge}$. Of all candidate isotopes for 0$νββ$, $^{76}\mathrm{Ge}$ has some of the most favorable characteristics. Germanium detectors are a well established technology, and in searches for 0$νββ$, the high purity germanium crystal acts simultaneously as source and detector. Furthermore, p-ty…
▽ More
The goal of the \textsc{Majorana} \textsc{Demonstrator} project is to search for 0$νββ$ decay in $^{76}\mathrm{Ge}$. Of all candidate isotopes for 0$νββ$, $^{76}\mathrm{Ge}$ has some of the most favorable characteristics. Germanium detectors are a well established technology, and in searches for 0$νββ$, the high purity germanium crystal acts simultaneously as source and detector. Furthermore, p-type germanium detectors provide excellent energy resolution and a specially designed point contact geometry allows for sensitive pulse shape discrimination. This paper will summarize the experiences the \textsc{Majorana} collaboration made with enriched germanium detectors manufactured by ORTEC$^{\circledR}$. The process from production, to characterization and integration in \textsc{Majorana} mounting structure will be described. A summary of the performance of all enriched germanium detectors will be given.
△ Less
Submitted 5 February, 2015;
originally announced February 2015.
-
The Majorana Demonstrator: A Search for Neutrinoless Double-beta Decay of 76Ge
Authors:
Majorana Collaboration,
W. Xu,
N. Abgrall,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
C. Cuesta,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
G. K. Giovanetti,
J. Goett,
M. P. Green,
J. Gruszko,
I. Guinn,
V. E. Guiseppe
, et al. (41 additional authors not shown)
Abstract:
Neutrinoless double-beta decay is a hypothesized process where in some even-even nuclei it might be possible for two neutrons to simultaneously decay into two protons and two electrons without emitting neutrinos. This is possible only if neutrinos are Majorana particles, i.e. fermions that are their own antiparticles. Neutrinos being Majorana particles would explicitly violate lepton number conser…
▽ More
Neutrinoless double-beta decay is a hypothesized process where in some even-even nuclei it might be possible for two neutrons to simultaneously decay into two protons and two electrons without emitting neutrinos. This is possible only if neutrinos are Majorana particles, i.e. fermions that are their own antiparticles. Neutrinos being Majorana particles would explicitly violate lepton number conservation, and might play a role in the matter-antimatter asymmetry in the universe. The observation of neutrinoless double-beta decay would also provide complementary information related to neutrino masses. The Majorana Collaboration is constructing the Majorana Demonstrator, a 40-kg modular germanium detector array, to search for the Neutrinoless double-beta decay of 76Ge and to demonstrate a background rate at or below 3 counts/(ROI-t-y) in the 4 keV region of interest (ROI) around the 2039 keV Q-value for 76Ge Neutrinoless double-beta decay. In this paper, we discuss the physics of neutrinoless double beta decay and then focus on the Majorana Demonstrator, including its design and approach to achieve ultra-low backgrounds and the status of the experiment.
△ Less
Submitted 9 May, 2015; v1 submitted 13 January, 2015;
originally announced January 2015.
-
Status of the MAJORANA Demonstrator
Authors:
C. Cuesta,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
J. A. Detwiler,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
G. K. Giovanetti,
J. Goett,
M. P. Greenn,
J. Gruszko,
I. S. Guinn,
V. E. Guiseppe,
R. Henning
, et al. (42 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 40-kg modular high purity Ge detector array to search for neutrinoless double-beta decay in Ge. In view of the next generation of tonne-scale Ge-based neutrinoless double-beta decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the Demonstrator is to d…
▽ More
The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 40-kg modular high purity Ge detector array to search for neutrinoless double-beta decay in Ge. In view of the next generation of tonne-scale Ge-based neutrinoless double-beta decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value at 2039 keV. The current status of the Demonstrator is discussed, as are plans for its completion.
△ Less
Submitted 7 January, 2015; v1 submitted 17 December, 2014;
originally announced December 2014.
-
A Dark Matter Search with MALBEK
Authors:
G. K. Giovanetti,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
C. Cuesta,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri
, et al. (62 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an array of natural and enriched high purity germanium detectors that will search for the neutrinoless double-beta decay of 76-Ge and perform a search for weakly interacting massive particles (WIMPs) with masses below 10 GeV. As part of the MAJORANA research and development efforts, we have deployed a modified, low-background broad energy germanium detector at the Kimb…
▽ More
The MAJORANA DEMONSTRATOR is an array of natural and enriched high purity germanium detectors that will search for the neutrinoless double-beta decay of 76-Ge and perform a search for weakly interacting massive particles (WIMPs) with masses below 10 GeV. As part of the MAJORANA research and development efforts, we have deployed a modified, low-background broad energy germanium detector at the Kimballton Underground Research Facility. With its sub-keV energy threshold, this detector is sensitive to potential non-Standard Model physics, including interactions with WIMPs. We discuss the backgrounds present in the WIMP region of interest and explore the impact of slow surface event contamination when searching for a WIMP signal.
△ Less
Submitted 8 July, 2014;
originally announced July 2014.
-
Background Model for the Majorana Demonstrator
Authors:
C. Cuesta,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
C. Cuesta,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri
, et al. (63 additional authors not shown)
Abstract:
The Majorana Collaboration is constructing a system containing 40 kg of HPGe detectors to demonstrate the feasibility and potential of a future tonne-scale experiment capable of probing the neutrino mass scale in the inverted-hierarchy region. To realize this, a major goal of the Majorana Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 cnt/(ROI-t-y) in th…
▽ More
The Majorana Collaboration is constructing a system containing 40 kg of HPGe detectors to demonstrate the feasibility and potential of a future tonne-scale experiment capable of probing the neutrino mass scale in the inverted-hierarchy region. To realize this, a major goal of the Majorana Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 cnt/(ROI-t-y) in the 4 keV region of interest around the Q-value at 2039 keV. This goal is pursued through a combination of a significant reduction of radioactive impurities in construction materials with analytical methods for background rejection, for example using powerful pulse shape analysis techniques profiting from the p-type point contact HPGe detectors technology. The effectiveness of these methods is assessed using simulations of the different background components whose purity levels are constrained from radioassay measurements.
△ Less
Submitted 6 May, 2014;
originally announced May 2014.
-
Testing the Ge detectors for the MAJORANA DEMONSTRATOR
Authors:
W. Xu,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
C. Cuesta,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri
, et al. (62 additional authors not shown)
Abstract:
High purity germanium (HPGe) crystals will be used for the MAJORANA DEMONSTRATOR, where they serve as both the source and the detector for neutrinoless double beta decay. It is crucial for the experiment to understand the performance of the HPGe crystals. A variety of crystal properties are being investigated, including basic properties such as energy resolution, efficiency, uniformity, capacitanc…
▽ More
High purity germanium (HPGe) crystals will be used for the MAJORANA DEMONSTRATOR, where they serve as both the source and the detector for neutrinoless double beta decay. It is crucial for the experiment to understand the performance of the HPGe crystals. A variety of crystal properties are being investigated, including basic properties such as energy resolution, efficiency, uniformity, capacitance, leakage current and crystal axis orientation, as well as more sophisticated properties, e.g. pulse shapes and dead layer and transition layer distributions. In this paper, we will present our measurements that characterize the HPGe crystals. We will also discuss our simulation package for the detector characterization setup, and show that additional information can be extracted from data-simulation comparisons.
△ Less
Submitted 29 April, 2014;
originally announced April 2014.
-
A search for bremsstrahlung solar axions using the Majorana low-background BEGe detector at Kimballton (MALBEK)
Authors:
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
R. J. Cooper,
R. J. Creswick,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
S. R. Elliott,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri,
G. K. Giovanetti,
J. Goett
, et al. (54 additional authors not shown)
Abstract:
A low-background, high-purity germanium detector has been used to search for evidence of low-energy, bremsstrahlung-generated solar axions. An upper bound of $1.36\times 10^{-11}$ $(95% CL)$ is placed on the direct coupling of DFSZ model axions to electrons. The prospects for the sensitivity of the Majorana Demonstrator array of point-contact germanium detectors to solar axions are discussed in th…
▽ More
A low-background, high-purity germanium detector has been used to search for evidence of low-energy, bremsstrahlung-generated solar axions. An upper bound of $1.36\times 10^{-11}$ $(95% CL)$ is placed on the direct coupling of DFSZ model axions to electrons. The prospects for the sensitivity of the Majorana Demonstrator array of point-contact germanium detectors to solar axions are discussed in the context of the model-independent annual modulation due to the seasonal variation of the earth-sun distance.
△ Less
Submitted 17 March, 2014; v1 submitted 3 March, 2014;
originally announced March 2014.
-
Status of the MAJORANA DEMONSTRATOR experiment
Authors:
MAJORANA Collaboration,
R. D. Martin,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. Esterline,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri
, et al. (60 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR neutrinoless double beta-decay experiment is currently under construction at the Sanford Underground Research Facility in South Dakota, USA. An overview and status of the experiment are given.
The MAJORANA DEMONSTRATOR neutrinoless double beta-decay experiment is currently under construction at the Sanford Underground Research Facility in South Dakota, USA. An overview and status of the experiment are given.
△ Less
Submitted 13 November, 2013;
originally announced November 2013.
-
The {\sc Majorana Demonstrator} Neutrinoless Double-Beta Decay Experiment
Authors:
Majorana Collaboration,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. Esterline,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri,
G. K. Giovanetti
, et al. (60 additional authors not shown)
Abstract:
The {\sc Majorana Demonstrator will search for the neutrinoless double-beta decay of the isotope Ge-76 with a mixed array of enriched and natural germanium detectors. The observation of this rare decay would indicate the neutrino is its own antiparticle, demonstrate that lepton number is not conserved, and provide information on the absolute mass scale of the neutrino. The {\sc Demonstrator} is be…
▽ More
The {\sc Majorana Demonstrator will search for the neutrinoless double-beta decay of the isotope Ge-76 with a mixed array of enriched and natural germanium detectors. The observation of this rare decay would indicate the neutrino is its own antiparticle, demonstrate that lepton number is not conserved, and provide information on the absolute mass scale of the neutrino. The {\sc Demonstrator} is being assembled at the 4850-foot level of the Sanford Underground Research Facility in Lead, South Dakota. The array will be situated in a low-background environment and surrounded by passive and active shielding. Here we describe the science goals of the {\sc Demonstrator} and the details of its design.
△ Less
Submitted 7 August, 2013;
originally announced August 2013.
-
The MAJORANA DEMONSTRATOR: A Search for Neutrinoless Double-beta Decay of Germanium-76
Authors:
MAJORANA Collaboration,
S. R. Elliott,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
J. Esterline,
J. E. Fast,
P. Finnerty,
F. M. Fraenkleo,
A. Galindo-Uribarri,
G. K. Giovanetti
, et al. (58 additional authors not shown)
Abstract:
The {\sc Majorana} collaboration is searching for neutrinoless double beta decay using $^{76}$Ge, which has been shown to have a number of advantages in terms of sensitivities and backgrounds. The observation of neutrinoless double-beta decay would show that lepton number is violated and that neutrinos are Majorana particles and would simultaneously provide information on neutrino mass. Attaining…
▽ More
The {\sc Majorana} collaboration is searching for neutrinoless double beta decay using $^{76}$Ge, which has been shown to have a number of advantages in terms of sensitivities and backgrounds. The observation of neutrinoless double-beta decay would show that lepton number is violated and that neutrinos are Majorana particles and would simultaneously provide information on neutrino mass. Attaining sensitivities for neutrino masses in the inverted hierarchy region, $15 - 50$ meV, will require large, tonne-scale detectors with extremely low backgrounds, at the level of $\sim$1 count/t-y or lower in the region of the signal. The {\sc Majorana} collaboration, with funding support from DOE Office of Nuclear Physics and NSF Particle Astrophysics, is constructing the {\sc Demonstrator}, an array consisting of 40 kg of p-type point-contact high-purity germanium (HPGe) detectors, of which $\sim$30 kg will be enriched to 87% in $^{76}$Ge. The {\sc Demonstrator} is being constructed in a clean room laboratory facility at the 4850' level (4300 m.w.e.) of the Sanford Underground Research Facility (SURF) in Lead, SD. It utilizes a compact graded shield approach with the inner portion consisting of ultra-clean Cu that is being electroformed and machined underground. The primary aim of the {\sc Demonstrator} is to show the feasibility of a future tonne-scale measurement in terms of backgrounds and scalability.
△ Less
Submitted 29 July, 2013;
originally announced July 2013.
-
The MAJORANA DEMONSTRATOR: Progress towards showing the feasibility of a tonne-scale 76Ge neutrinoless double-beta decay experiment
Authors:
P. Finnerty,
E. Aguayo,
M. Amman,
F. T. Avignone. III,
A. S. Barabash,
P. J. Barton,
J. R. Beene,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
Y. -D. Chan,
C. D. Christofferson,
J. I. Collar,
D. C. Combs,
R. J. Cooper,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. Esterline,
J. E. Fast,
N. Fields
, et al. (58 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR will search for the neutrinoless double-beta decay of the 76Ge isotope with a mixed array of enriched and natural germanium detectors. The observation of this rare decay would indicate the neutrino is its own anti-particle, demonstrate that lepton number is not conserved, and provide information on the absolute mass-scale of the neutrino. The DEMONSTRATOR is being assembl…
▽ More
The MAJORANA DEMONSTRATOR will search for the neutrinoless double-beta decay of the 76Ge isotope with a mixed array of enriched and natural germanium detectors. The observation of this rare decay would indicate the neutrino is its own anti-particle, demonstrate that lepton number is not conserved, and provide information on the absolute mass-scale of the neutrino. The DEMONSTRATOR is being assembled at the 4850 foot level of the Sanford Underground Research Facility in Lead, South Dakota. The array will be contained in a low-background environment and surrounded by passive and active shielding. The goals for the DEMONSTRATOR are: demonstrating a background rate less than 3 t$^{-1}$ y$^{-1}$ in the 4 keV region of interest (ROI) surrounding the 2039 keV 76Ge endpoint energy; establishing the technology required to build a tonne-scale germanium based double-beta decay experiment; testing the recent claim of observation of neutrinoless double-beta decay [H. V. Klapdor-Kleingrothaus and I. V. Krivosheina, Mod. Phys. Lett. A21, 1547 (2006)]; and performing a direct search for light WIMPs (3-10 GeV).
△ Less
Submitted 9 October, 2012;
originally announced October 2012.