-
$^{171}$Yb$^+$ optical clock with $2.2\times 10^{-18}$ systematic uncertainty and absolute frequency measurements
Authors:
Alexandra Tofful,
Charles F. A. Baynham,
E. Anne Curtis,
Adam O. Parsons,
Billy I. Robertson,
Marco Schioppo,
Jacob Tunesi,
Helen S. Margolis,
Richard J. Hendricks,
Josh Whale,
Richard C. Thompson,
Rachel M. Godun
Abstract:
A full evaluation of the uncertainty budget for the ytterbium ion optical clock at the National Physical Laboratory (NPL) was performed on the electric octupole (E3) $^2\mathrm{S}_{1/2}\,\rightarrow\, ^2\mathrm{F}_{7/2}$ transition. The total systematic frequency shift was measured with a fractional standard systematic uncertainty of $2.2\times 10^{-18}$. Furthermore, the absolute frequency of the…
▽ More
A full evaluation of the uncertainty budget for the ytterbium ion optical clock at the National Physical Laboratory (NPL) was performed on the electric octupole (E3) $^2\mathrm{S}_{1/2}\,\rightarrow\, ^2\mathrm{F}_{7/2}$ transition. The total systematic frequency shift was measured with a fractional standard systematic uncertainty of $2.2\times 10^{-18}$. Furthermore, the absolute frequency of the E3 transition of the $^{171}$Yb$^+$ ion was measured between 2019 and 2023 via a link to International Atomic Time (TAI) and against the local caesium fountain NPL-CsF2. The absolute frequencies were measured with fractional standard uncertainties between $3.7 \times 10^{-16}$ and $1.1 \times 10^{-15}$, and all were in agreement with the 2021 BIPM recommended frequency.
△ Less
Submitted 21 March, 2024;
originally announced March 2024.
-
Progress towards ultracold Sr for the AION project -- sub-microkelvin atoms and an optical-heterodyne diagnostic tool for injection-locked laser diodes
Authors:
E. Pasatembou,
C. F. A. Baynham,
O. Buchmüller,
D. Evans,
R. Hobson,
L. Iannizzotto-Venezze,
A. Josset
Abstract:
Long-baseline atom interferometers, such as the one to be built by the AION collaboration, require ultra-cold atomic clouds. These are produced by trapping the atoms in Magneto-Optical Traps (MOTs) using high-power, narrow-linewidth lasers. We report on the laser and optical master-slave injection locked system used to address the 1S0 - 3P1 strontium transition at 689 nm, and on the trapping of st…
▽ More
Long-baseline atom interferometers, such as the one to be built by the AION collaboration, require ultra-cold atomic clouds. These are produced by trapping the atoms in Magneto-Optical Traps (MOTs) using high-power, narrow-linewidth lasers. We report on the laser and optical master-slave injection locked system used to address the 1S0 - 3P1 strontium transition at 689 nm, and on the trapping of strontium atoms in a narrowband MOT. We demonstrate the quality of the injection through the characterisation of the injection lock using a novel, easy-to-assemble method which uses a double pass acousto-optic modulator (AOM) to generate and detect a heterodyne beatnote. The reported system is used to produce an atomic cloud at a temperature of 812 +/- 43 nK in a narrowband red MOT.
△ Less
Submitted 12 October, 2023;
originally announced October 2023.
-
Centralised Design and Production of the Ultra-High Vacuum and Laser-Stabilisation Systems for the AION Ultra-Cold Strontium Laboratories
Authors:
B. Stray,
O. Ennis,
S. Hedges,
S. Dey,
M. Langlois,
K. Bongs,
S. Lellouch,
M. Holynski,
B. Bostwick,
J. Chen,
Z. Eyler,
V. Gibson,
T. L. Harte,
M. Hsu,
M. Karzazi,
J. Mitchell,
N. Mouelle,
U. Schneider,
Y. Tang,
K. Tkalcec,
Y. Zhi,
K. Clarke,
A. Vick,
K. Bridges,
J. Coleman
, et al. (47 additional authors not shown)
Abstract:
This paper outlines the centralised design and production of the Ultra-High-Vacuum sidearm and Laser-Stabilisation systems for the AION Ultra-Cold Strontium Laboratories. Commissioning data on the residual gas and steady-state pressures in the sidearm chambers, on magnetic field quality, on laser stabilisation, and on the loading rate for the 3D Magneto-Optical Trap are presented. Streamlining the…
▽ More
This paper outlines the centralised design and production of the Ultra-High-Vacuum sidearm and Laser-Stabilisation systems for the AION Ultra-Cold Strontium Laboratories. Commissioning data on the residual gas and steady-state pressures in the sidearm chambers, on magnetic field quality, on laser stabilisation, and on the loading rate for the 3D Magneto-Optical Trap are presented. Streamlining the design and production of the sidearm and laser stabilisation systems enabled the AION Collaboration to build and equip in parallel five state-of-the-art Ultra-Cold Strontium Laboratories within 24 months by leveraging key expertise in the collaboration. This approach could serve as a model for the development and construction of other cold atom experiments, such as atomic clock experiments and neutral atom quantum computing systems, by establishing dedicated design and production units at national laboratories.
△ Less
Submitted 31 May, 2023;
originally announced May 2023.
-
Analysis of atomic-clock data to constrain variations of fundamental constants
Authors:
Nathaniel Sherrill,
Adam O. Parsons,
Charles F. A. Baynham,
William Bowden,
E. Anne Curtis,
Richard Hendricks,
Ian R. Hill,
Richard Hobson,
Helen S. Margolis,
Billy I. Robertson,
Marco Schioppo,
Krzysztof Szymaniec,
Alexandra Tofful,
Jacob Tunesi,
Rachel M. Godun,
Xavier Calmet
Abstract:
We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on $^{87}$Sr, $^{171}$Yb$^+$ and $^{133}$Cs, we set bounds on parameters controlling the variation of the fine-structure constant, $α$, and the electron-to-proton mass ratio,…
▽ More
We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on $^{87}$Sr, $^{171}$Yb$^+$ and $^{133}$Cs, we set bounds on parameters controlling the variation of the fine-structure constant, $α$, and the electron-to-proton mass ratio, $μ$. We consider variations on timescales ranging from a minute to almost a day. In addition, we use our results to derive some of the tightest limits to date on the parameter space of models of ultralight dark matter and axion-like particles.
△ Less
Submitted 15 December, 2023; v1 submitted 9 February, 2023;
originally announced February 2023.
-
Cold Atoms in Space: Community Workshop Summary and Proposed Road-Map
Authors:
Ivan Alonso,
Cristiano Alpigiani,
Brett Altschul,
Henrique Araujo,
Gianluigi Arduini,
Jan Arlt,
Leonardo Badurina,
Antun Balaz,
Satvika Bandarupally,
Barry C Barish Michele Barone,
Michele Barsanti,
Steven Bass,
Angelo Bassi,
Baptiste Battelier,
Charles F. A. Baynham,
Quentin Beaufils,
Aleksandar Belic,
Joel Berge,
Jose Bernabeu,
Andrea Bertoldi,
Robert Bingham,
Sebastien Bize,
Diego Blas,
Kai Bongs,
Philippe Bouyer
, et al. (224 additional authors not shown)
Abstract:
We summarize the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, a…
▽ More
We summarize the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with ESA and national space and research funding agencies.
△ Less
Submitted 19 January, 2022;
originally announced January 2022.
-
A strontium optical lattice clock with $1 \times 10^{-17}$ uncertainty and measurement of its absolute frequency
Authors:
Richard Hobson,
William Bowden,
Alissa Silva,
Charles F. A. Baynham,
Helen S. Margolis,
Patrick E. G. Baird,
Patrick Gill,
Ian R. Hill
Abstract:
We present a measurement of the absolute frequency of the 5s$^2$ $^1$S$_0$ to 5s5p $^3$P$_0$ transition in $^{87}$Sr, which is a secondary representation of the SI second. We describe the optical lattice clock apparatus used for the measurement, and we focus in detail on how its systematic frequency shifts are evaluated with a total fractional uncertainty of $1 \times 10^{-17}$. Traceability to th…
▽ More
We present a measurement of the absolute frequency of the 5s$^2$ $^1$S$_0$ to 5s5p $^3$P$_0$ transition in $^{87}$Sr, which is a secondary representation of the SI second. We describe the optical lattice clock apparatus used for the measurement, and we focus in detail on how its systematic frequency shifts are evaluated with a total fractional uncertainty of $1 \times 10^{-17}$. Traceability to the International System of Units is provided via comparison to International Atomic Time (TAI). Gathering data over 5- and 15-day periods, with the lattice clock operating on average 74$\%$ of the time, we measure the frequency of the transition to be 429228004229873.1(5) Hz, which corresponds to a fractional uncertainty of $1 \times 10^{-15}$. We describe in detail how this uncertainty arises from the intermediate steps linking the optical frequency standard, through our local time scale UTC(NPL), to an ensemble of primary and secondary frequency standards which steer TAI. The calculated absolute frequency of the transition is in good agreement with recent measurements carried out in other laboratories around the world.
△ Less
Submitted 21 May, 2020;
originally announced May 2020.
-
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Authors:
F. Riedel,
A. Al-Masoudi,
E. Benkler,
S. Dörscher,
V. Gerginov,
C. Grebing,
S. Häfner,
N. Huntemann,
B. Lipphardt,
C. Lisdat,
E. Peik,
D. Piester,
C. Sanner,
C. Tamm,
S. Weyers,
H. Denker,
L. Timmen,
C. Voigt,
D. Calonico,
G. Cerretto,
G. A. Costanzo,
F. Levi,
I. Sesia,
J. Achkar,
J. Guèna
, et al. (24 additional authors not shown)
Abstract:
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki…
▽ More
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks
Authors:
B. M. Roberts,
P. Delva,
A. Al-Masoudi,
A. Amy-Klein,
C. Bærentsen,
C. F. A. Baynham,
E. Benkler,
S. Bilicki,
S. Bize,
W. Bowden,
J. Calvert,
V. Cambier,
E. Cantin,
E. A. Curtis,
S. Dörscher,
M. Favier,
F. Frank,
P. Gill,
R. M. Godun,
G. Grosche,
C. Guo,
A. Hees,
I. R. Hill,
R. Hobson,
N. Huntemann
, et al. (29 additional authors not shown)
Abstract:
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17…
▽ More
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.
△ Less
Submitted 8 July, 2019; v1 submitted 4 July, 2019;
originally announced July 2019.
-
Measurement of differential polarizabilities at a mid-infrared wavelength in $^{171}\mathrm{Yb}^+$
Authors:
C F A Baynham,
E A Curtis,
R M Godun,
J M Jones,
P B R Nisbet-Jones,
P E G Baird,
K Bongs,
P Gill,
T Fordell,
T Hieta,
T Lindvall,
M T Spidell,
J H Lehman
Abstract:
An atom exposed to an electric field will experience Stark shifts of its internal energy levels, proportional to their polarizabilities. In optical frequency metrology, the Stark shift due to background black-body radiation (BBR) modifies the frequency of the optical clock transition, and often represents a large contribution to a clock's uncertainty budget. For clocks based on singly-ionized ytte…
▽ More
An atom exposed to an electric field will experience Stark shifts of its internal energy levels, proportional to their polarizabilities. In optical frequency metrology, the Stark shift due to background black-body radiation (BBR) modifies the frequency of the optical clock transition, and often represents a large contribution to a clock's uncertainty budget. For clocks based on singly-ionized ytterbium, the ion's complex structure makes this shift difficult to calculate theoretically. We present a measurement of the differential polarizabilities of two ultra-narrow optical clock transitions present in $^{171}\mathrm{Yb}^+$, performed by exposing the ion to an oscillating electric field at a wavelength in the region of room temperature BBR spectra. By measuring the frequency shift to the transitions caused by a laser at $λ=7.17 μm$, we obtain values for scalar and tensor differential polarizabilities with uncertainties at the percent level for both the electric quadrupole and octupole transitions at 436nm and 467nm respectively. These values agree with previously reported experimental measurements and, in the case of the electric quadrupole transition, allow a 5-fold improvement in the determination of the room-temperature BBR shift.
However, we note significant concerns over the validity of the uncertainty charactarization presented and draw the reader's attention to the Note on applicability section for a discussion.
△ Less
Submitted 10 September, 2020; v1 submitted 30 January, 2018;
originally announced January 2018.
-
Absolute frequency measurement of the $^2$S$_{1/2} \rightarrow ^2$F$_{7/2}$ optical clock transition in $^{171}$Yb$^+$ with an uncertainty of $4\times 10^{-16}$ using a frequency link to International Atomic Time
Authors:
Charles F. A. Baynham,
Rachel M. Godun,
Jonathan M. Jones,
Steven A. King,
Peter B. R. Nisbet-Jones,
Fred Baynes,
Antoine Rolland,
Patrick E. G. Baird,
Kai Bongs,
Patrick Gill,
Helen S. Margolis
Abstract:
The highly forbidden $^2$S$_{1/2} \rightarrow ^2$F$_{7/2}$ electric octupole transition in $^{171}$Yb$^+$ is a potential candidate for a redefinition of the SI second. We present a measurement of the absolute frequency of this optical transition, performed using a frequency link to International Atomic Time to provide traceability to the SI second. The $^{171}$Yb$^+$ optical frequency standard was…
▽ More
The highly forbidden $^2$S$_{1/2} \rightarrow ^2$F$_{7/2}$ electric octupole transition in $^{171}$Yb$^+$ is a potential candidate for a redefinition of the SI second. We present a measurement of the absolute frequency of this optical transition, performed using a frequency link to International Atomic Time to provide traceability to the SI second. The $^{171}$Yb$^+$ optical frequency standard was operated for 76% of a 25-day period, with the absolute frequency measured to be 642 121 496 772 645.14(26) Hz. The fractional uncertainty of $4.0 \times 10 ^{-16}$ is comparable to that of the best previously reported measurement, which was made by a direct comparison to local caesium primary frequency standards.
△ Less
Submitted 27 October, 2017; v1 submitted 3 July, 2017;
originally announced July 2017.
-
A Single-Ion Trap with Minimized Ion-Environment Interactions
Authors:
P. B. R. Nisbet-Jones,
S. A. King,
J. M. Jones,
R. M. Godun,
C. F. A. Baynham,
K. Bongs,
M. Doležal,
P. Balling,
P. Gill
Abstract:
We present a new single-ion endcap trap for high precision spectroscopy that has been designed to minimize ion-environment interactions. We describe the design in detail and then characterize the working trap using a single trapped 171 Yb ion. Excess micromotion has been eliminated to the resolution of the detection method and the trap exhibits an anomalous phonon heating rate of d<n> /dt = 24 +30…
▽ More
We present a new single-ion endcap trap for high precision spectroscopy that has been designed to minimize ion-environment interactions. We describe the design in detail and then characterize the working trap using a single trapped 171 Yb ion. Excess micromotion has been eliminated to the resolution of the detection method and the trap exhibits an anomalous phonon heating rate of d<n> /dt = 24 +30/-24 per second. The thermal properties of the trap structure have also been measured with an effective temperature rise at the ion's position of 0.14 +/- 0.14 K. The small perturbations to the ion caused by this trap make it suitable to be used for an optical frequency standard with fractional uncertainties below the 10^-18 level.
△ Less
Submitted 19 March, 2021; v1 submitted 21 October, 2015;
originally announced October 2015.