-
Modeling Athermal Phonons in Novel Materials using the G4CMP Simulation Toolkit
Authors:
Israel Hernandez,
Ryan Linehan,
Rakshya Khatiwada,
Kester Anyang,
Daniel Baxter,
Grace Bratrud,
Enectali Figueroa-Feliciano,
Lauren Hsu,
Mike Kelsey,
Dylan Temples
Abstract:
Understanding phonon and charge propagation in superconducting devices plays an important role in both performing low-threshold dark matter searches and limiting correlated errors in superconducting qubits. The Geant4 Condensed Matter Physics (G4CMP) package, originally developed for the Cryogenic Dark Matter Search (CDMS) experiment, models charge and phonon transport within silicon and germanium…
▽ More
Understanding phonon and charge propagation in superconducting devices plays an important role in both performing low-threshold dark matter searches and limiting correlated errors in superconducting qubits. The Geant4 Condensed Matter Physics (G4CMP) package, originally developed for the Cryogenic Dark Matter Search (CDMS) experiment, models charge and phonon transport within silicon and germanium detectors and has been validated by experimental measurements of phonon caustics, mean charge-carrier drift velocities, and heat pulse propagation times. In this work, we present a concise framework for expanding the capabilities for phonon transport to a number of other novel substrate materials of interest to the dark matter and quantum computing communities, including sapphire (Al$_{2}$O$_{3}$), gallium arsenide (GaAs), lithium fluoride (LiF), calcium tungstate (CaWO$_{4}$), and calcium fluoride (CaF$_{2}$). We demonstrate the use of this framework in generating phonon transport properties of these materials and compare these properties with experimentally-determined values where available.
△ Less
Submitted 8 August, 2024;
originally announced August 2024.
-
First Measurement of Correlated Charge Noise in Superconducting Qubits at an Underground Facility
Authors:
G. Bratrud,
S. Lewis,
K. Anyang,
A. Colón Cesaní,
T. Dyson,
H. Magoon,
D. Sabhari,
G. Spahn,
G. Wagner,
R. Gualtieri,
N. A. Kurinsky,
R. Linehan,
R. McDermott,
S. Sussman,
D. J. Temples,
S. Uemura,
C. Bathurst,
G. Cancelo,
R. Chen,
A. Chou,
I. Hernandez,
M. Hollister,
L. Hsu,
C. James,
K. Kennard
, et al. (13 additional authors not shown)
Abstract:
We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth's surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4$π$ coverage of a movable lead s…
▽ More
We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth's surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4$π$ coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of 0.19$^{+0.04}_{-0.03}$ mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly eight higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.
△ Less
Submitted 27 June, 2024; v1 submitted 7 May, 2024;
originally announced May 2024.
-
Cryogenic optical beam steering for superconducting device calibration
Authors:
K. Stifter,
H. Magoon,
A. J. Anderson,
D. J. Temples,
N. A. Kurinsky,
C. Stoughton,
I. Hernandez,
A. Nuñez,
K. Anyang,
R. Linehan,
M. R. Young,
P. Barry,
D. Baxter,
D. Bowring,
G. Cancelo,
A. Chou,
K. R. Dibert,
E. Figueroa-Feliciano,
L. Hsu,
R. Khatiwada,
S. D. Mork,
L. Stefanazzi,
N. Tabassum,
S. Uemura,
B. A. Young
Abstract:
We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $μ$m, enabling charac…
▽ More
We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This portable, integrated system can steer the beam over a $\sim$3 cm $\times$ 3 cm area on the surface of any sensor with a precision of $\sim$100 $μ$m, enabling characterization of device response as a function of position. This fills a critical need in the landscape of calibration tools for sub-Kelvin devices, including those used for dark matter detection and quantum computing. These communities have a shared goal of understanding the impact of ionizing radiation on device performance, which can be pursued with our system. This paper describes the design of the first-generation calibration system and the results from successfully testing its performance at room temperature and 20 mK.
△ Less
Submitted 3 May, 2024;
originally announced May 2024.
-
Estimating the Energy Threshold of Phonon-mediated Superconducting Qubit Detectors Operated in an Energy-Relaxation Sensing Scheme
Authors:
R. Linehan,
I. Hernandez,
D. J. Temples,
S. Q. Dang,
D. Baxter,
L. Hsu,
E. Figueroa-Feliciano,
R. Khatiwada,
K. Anyang,
D. Bowring,
G. Bratrud,
G. Cancelo,
A. Chou,
R. Gualtieri,
K. Stifter,
S. Sussman
Abstract:
In recent years, the lack of a conclusive detection of WIMP dark matter at the 10 GeV/c$^{2}$ mass scale and above has encouraged development of low-threshold detector technology aimed at probing lighter dark matter candidates. Detectors based on Cooper-pair-breaking sensors have emerged as a promising avenue for this detection due to the low (meV-scale) energy required for breaking a Cooper pair…
▽ More
In recent years, the lack of a conclusive detection of WIMP dark matter at the 10 GeV/c$^{2}$ mass scale and above has encouraged development of low-threshold detector technology aimed at probing lighter dark matter candidates. Detectors based on Cooper-pair-breaking sensors have emerged as a promising avenue for this detection due to the low (meV-scale) energy required for breaking a Cooper pair in most superconductors. Among them, devices based on superconducting qubits are interesting candidates for sensing due to their observed sensitivity to broken Cooper pairs. We have developed an end-to-end G4CMP-based simulation framework and have used it to evaluate performance metrics of qubit-based devices operating in a gate-based "energy relaxation" readout scheme, akin to those used in recent studies of qubit sensitivity to ionizing radiation. We find that for this readout scheme, the qubit acts as a phonon sensor with an energy threshold ranging down to $\simeq$0.4 eV for near-term performance parameters.
△ Less
Submitted 5 April, 2024;
originally announced April 2024.