-
Correlations between X-rays, Visible Light and Drive-Beam Energy Loss Observed in Plasma Wakefield Acceleration Experiments at FACET-II
Authors:
Chaojie Zhang,
Doug Storey,
Pablo San Miguel Claveria,
Zan Nie,
Ken A. Marsh,
Warren B. Mori,
Erik Adli,
Weiming An,
Robert Ariniello,
Gevy J. Cao,
Christine Clark,
Sebastien Corde,
Thamine Dalichaouch,
Christopher E. Doss,
Claudio Emma,
Henrik Ekerfelt,
Elias Gerstmayr,
Spencer Gessner,
Claire Hansel,
Alexander Knetsch,
Valentina Lee,
Fei Li,
Mike Litos,
Brendan O'Shea,
Glen White
, et al. (4 additional authors not shown)
Abstract:
This study documents several correlations observed during the first run of the plasma wakefield acceleration experiment E300 conducted at FACET-II, using a single drive electron bunch. The established correlations include those between the measured maximum energy loss of the drive electron beam and the integrated betatron x-ray signal, the calculated total beam energy deposited in the plasma and t…
▽ More
This study documents several correlations observed during the first run of the plasma wakefield acceleration experiment E300 conducted at FACET-II, using a single drive electron bunch. The established correlations include those between the measured maximum energy loss of the drive electron beam and the integrated betatron x-ray signal, the calculated total beam energy deposited in the plasma and the integrated x-ray signal, among three visible light emission measuring cameras, and between the visible plasma light and x-ray signal. The integrated x-ray signal correlates almost linearly with both the maximum energy loss of the drive beam and the energy deposited into the plasma, demonstrating its usability as a measure of energy transfer from the drive beam to the plasma. Visible plasma light is found to be a useful indicator of the presence of wake at three locations that overall are two meters apart. Despite the complex dynamics and vastly different timescales, the x-ray radiation from the drive bunch and visible light emission from the plasma may prove to be effective non-invasive diagnostics for monitoring the energy transfer from the beam to the plasma in future high-repetition-rate experiments.
△ Less
Submitted 29 April, 2024;
originally announced April 2024.
-
The E302 instability-versus-efficiency experiment at FACET-II
Authors:
O. G. Finnerud,
C. A. Lindstrøm,
J. B. B. Chen,
E. Adli
Abstract:
We discuss plans for the E302 instability-efficiency experiment, starting in 2024 at the recently upgraded FACET-II facility at SLAC National Accelerator Laboratory. The beam-breakup instability will be the main area of study for the E302 experiment. With the imaging spectrometer at FACET-II, we introduce a novel technique for observing and quantifying the amplitude growth of the trailing bunch du…
▽ More
We discuss plans for the E302 instability-efficiency experiment, starting in 2024 at the recently upgraded FACET-II facility at SLAC National Accelerator Laboratory. The beam-breakup instability will be the main area of study for the E302 experiment. With the imaging spectrometer at FACET-II, we introduce a novel technique for observing and quantifying the amplitude growth of the trailing bunch due to the transverse instability. Using the transverse position on the spectrometer screen and the transfer matrix of the magnetic lattice used for the spectrometer, we aim to extract a $x'$-$E$ charge distribution that can be used to quantify the amplitude of the beam. By varying the trailing bunch's charge and, hence, the beam loading of the accelerating field, we aim to adjust the wake-to-beam power transfer efficiency in the E302 experiment. We plan to quantify the amplitude for different configurations of the beam charge and, hence, investigate the relationship between the beam-breakup instability and efficiency. We use a combination of particle-in-cell (PIC) codes to simulate a beam-driven plasma wakefield accelerator from start-to-end with a FACET-II-like spectrometer and demonstrate the methodology that will be used for the instability studies at the E302 experiment.
△ Less
Submitted 15 February, 2024;
originally announced February 2024.
-
Wakefield Generation in Hydrogen and Lithium Plasmas at FACET-II: Diagnostics and First Beam-Plasma Interaction Results
Authors:
D. Storey,
C. Zhang,
P. San Miguel Claveria,
G. J. Cao,
E. Adli,
L. Alsberg,
R. Ariniello,
C. Clarke,
S. Corde,
T. N. Dalichaouch,
H. Ekerfelt,
C. Emma,
E. Gerstmayr,
S. Gessner,
M. Gilljohann,
C. Hast,
A. Knetsch,
V. Lee,
M. Litos,
R. Loney,
K. A. Marsh,
A. Matheron,
W. B. Mori,
Z. Nie,
B. O'Shea
, et al. (6 additional authors not shown)
Abstract:
Plasma Wakefield Acceleration (PWFA) provides ultrahigh acceleration gradients of 10s of GeV/m, providing a novel path towards efficient, compact, TeV-scale linear colliders and high brightness free electron lasers. Critical to the success of these applications is demonstrating simultaneously high gradient acceleration, high energy transfer efficiency, and preservation of emittance, charge, and en…
▽ More
Plasma Wakefield Acceleration (PWFA) provides ultrahigh acceleration gradients of 10s of GeV/m, providing a novel path towards efficient, compact, TeV-scale linear colliders and high brightness free electron lasers. Critical to the success of these applications is demonstrating simultaneously high gradient acceleration, high energy transfer efficiency, and preservation of emittance, charge, and energy spread. Experiments at the FACET-II National User Facility at SLAC National Accelerator Laboratory aim to achieve all of these milestones in a single stage plasma wakefield accelerator, providing a 10 GeV energy gain in a <1 m plasma with high energy transfer efficiency. Such a demonstration depends critically on diagnostics able to measure emittance with mm-mrad accuracy, energy spectra to determine both %-level energy spread and broadband energy gain and loss, incoming longitudinal phase space, and matching dynamics. This paper discusses the experimental setup at FACET-II, including the incoming beam parameters from the FACET-II linac, plasma sources, and diagnostics developed to meet this challenge. Initial progress on the generation of beam ionized wakes in meter-scale hydrogen gas is discussed, as well as commissioning of the plasma sources and diagnostics.
△ Less
Submitted 9 October, 2023;
originally announced October 2023.
-
Generation of meter-scale hydrogen plasmas and efficient, pump-depletion-limited wakefield excitation using 10 GeV electron bunches
Authors:
C. Zhang,
D. Storey,
P. San Miguel Claveria,
Z. Nie,
K. A. Marsh,
M. Hogan,
W. B. Mori,
E. Adli,
W. An,
R. Ariniello,
G. J. Cao,
C. Clarke,
S. Corde,
T. Dalichaouch,
C. E. Doss,
C. Emma,
H. Ekerfelt,
E. Gerstmayr,
S. Gessner,
C. Hansel,
A. Knetsch,
V. Lee,
F. Li,
M. Litos,
B. O'Shea
, et al. (4 additional authors not shown)
Abstract:
High repetition rates and efficient energy transfer to the accelerating beam are important for a future linear collider based on the beam-driven plasma wakefield acceleration scheme (PWFA-LC). This paper reports the first results from the Plasma Wakefield Acceleration Collaboration (E300) that are beginning to address both of these issues using the recently commissioned FACET-II facility at SLAC.…
▽ More
High repetition rates and efficient energy transfer to the accelerating beam are important for a future linear collider based on the beam-driven plasma wakefield acceleration scheme (PWFA-LC). This paper reports the first results from the Plasma Wakefield Acceleration Collaboration (E300) that are beginning to address both of these issues using the recently commissioned FACET-II facility at SLAC. We have generated meter-scale hydrogen plasmas using time-structured 10 GeV electron bunches from FACET-II, which hold the promise of dramatically increasing the repetition rate of PWFA by rapidly replenishing the gas between each shot compared to the hitherto used lithium plasmas that operate at 1-10 Hz. Furthermore, we have excited wakes in such plasmas that are suitable for high gradient particle acceleration with high drive-bunch to wake energy transfer efficiency -- a first step in achieving a high overall energy transfer efficiency. We have done this by using time-structured electron drive bunches that typically have one or more ultra-high current (>30 kA) femtosecond spike(s) superimposed on a longer (~0.4 ps) lower current (<10 kA) bunch structure. The first spike effectively field-ionizes the gas and produces a meter-scale (30-160 cm) plasma, whereas the subsequent beam charge creates a wake. The length and amplitude of the wake depends on the longitudinal current profile of the bunch and plasma density. We find that the onset of pump depletion, when some of the drive beam electrons are nearly fully depleted of their energy, occurs for hydrogen pressure >1.5 Torr. We also show that some electrons in the rear of the bunch can gain several GeV energies from the wake. These results are reproduced by particle-in-cell simulations using the QPAD code. At a pressure of ~2 Torr, simulations results and experimental data show that the beam transfers about 60% of its energy to the wake.
△ Less
Submitted 9 October, 2023;
originally announced October 2023.
-
Positron Acceleration in Plasma Wakefields
Authors:
G. J. Cao,
C. A. Lindstrøm,
E. Adli,
S. Corde,
S. Gessner
Abstract:
Plasma acceleration has emerged as a promising technology for future particle accelerators, particularly linear colliders. Significant progress has been made in recent decades toward high-efficiency and high-quality acceleration of electrons in plasmas. However, this progress does not generalize to acceleration of positrons, as plasmas are inherently charge asymmetric. Here, we present a comprehen…
▽ More
Plasma acceleration has emerged as a promising technology for future particle accelerators, particularly linear colliders. Significant progress has been made in recent decades toward high-efficiency and high-quality acceleration of electrons in plasmas. However, this progress does not generalize to acceleration of positrons, as plasmas are inherently charge asymmetric. Here, we present a comprehensive review of historical and current efforts to accelerate positrons using plasma wakefields. Proposed schemes that aim to increase the energy efficiency and beam quality are summarised and quantitatively compared. A dimensionless metric that scales with the luminosity-per-beam power is introduced, indicating that positron-acceleration schemes are currently below the ultimate requirement for colliders. The primary issue is electron motion; the high mobility of plasma electrons compared to plasma ions, which leads to non-uniform accelerating and focusing fields that degrade the beam quality of the positron bunch, particularly for high efficiency acceleration. Finally, we discuss possible mitigation strategies and directions for future research.
△ Less
Submitted 5 March, 2024; v1 submitted 19 September, 2023;
originally announced September 2023.
-
CLIC Wake Field Monitor as a detuned Cavity Beam Position Monitor: Explanation of center offset between TE and TM channels in the TD26 structure
Authors:
Kyrre Ness Sjobak,
Hikmet Bursali,
Antonio Gillardi,
Reidar Lillestøl,
Wilfrid Farabolini,
Steffen Doebert,
Erik Adli,
Nuria Catalan Lasheras,
Roberto Corsini
Abstract:
The Wake Field Monitor (WFM) system installed on the CLIC prototype accelerating structure in CERN Linear Accelerator for Research (CLEAR) has two channels for each horizontal/vertical plane, operating at different frequencies. When moving the beam relative to the aperture of the structure, a disagreement is observed between the center position of the structure as measured with the two channels in…
▽ More
The Wake Field Monitor (WFM) system installed on the CLIC prototype accelerating structure in CERN Linear Accelerator for Research (CLEAR) has two channels for each horizontal/vertical plane, operating at different frequencies. When moving the beam relative to the aperture of the structure, a disagreement is observed between the center position of the structure as measured with the two channels in each plane. This is a challenge for the planned use of WFMs in the Compact Linear Collider (CLIC), where they will be used to measure the center offset between the accelerating structures and the beam. Through a mixture of simulations and measurements, we have discovered a potential mechanism for this, which is discussed along with implications for improving position resolution near the structure center, and the possibility determination of the sign of the beam offset.
△ Less
Submitted 13 July, 2023;
originally announced July 2023.
-
Beam Delivery and Beamstrahlung Considerations for Ultra-High Energy Linear Colliders
Authors:
Tim Barklow,
Spencer Gessner,
Mark Hogan,
Cho-Kuen Ng,
Michael Peskin,
Tor Raubenheimer,
Glen White,
Erik Adli,
Gevy Jiawei Cao,
Carl A. Lindstrom,
Kyrre Sjobak,
Sam Barber,
Cameron Geddes,
Arianna Formenti,
Remi Lehe,
Carl Schroeder,
Davide Terzani,
Jeroen van Tilborg,
Jean-Luc Vay,
Edoardo Zoni,
Chris Doss,
Michael Litos,
Ihar Lobach,
John Power,
Maximilian Swiatlowski
, et al. (5 additional authors not shown)
Abstract:
As part of the Snowmass'21 community planning excercise, the Advanced Accelerator Concepts (AAC) community proposed future linear colliders with center-of-mass energies up to 15 TeV and luminosities up to 50$\times10^{34}$ cm$^{-2}$s$^{-1}$ in a compact footprint. In addition to being compact, these machines must also be energy efficient. We identify two challenges that must be addressed in the de…
▽ More
As part of the Snowmass'21 community planning excercise, the Advanced Accelerator Concepts (AAC) community proposed future linear colliders with center-of-mass energies up to 15 TeV and luminosities up to 50$\times10^{34}$ cm$^{-2}$s$^{-1}$ in a compact footprint. In addition to being compact, these machines must also be energy efficient. We identify two challenges that must be addressed in the design of these machines. First, the Beam Delivery System (BDS) must not add significant length to the accelerator complex. Second, beam parameters must be chosen to mitigate beamstrahlung effects and maximize the luminosity-per-power of the machine. In this paper, we review advances in plasma lens technology that will help to reduce the length of the BDS system and we detail new Particle-in-Cell simulation studies that will provide insight into beamstrahlung mitigation techniques. We apply our analysis to both $e^+e^-$ and $γγ$ colliders.
△ Less
Submitted 31 May, 2023; v1 submitted 30 April, 2023;
originally announced May 2023.
-
Acceleration of a Positron Bunch in a Hollow Channel Plasma
Authors:
Spencer Gessner,
Erik Adli,
James M. Allen,
Weiming An,
Christine I. Clarke,
Chris E. Clayton,
Sebastien Corde,
Antoine Doche,
Joel Frederico,
Selina Z. Green,
Mark J. Hogan,
Chan Joshi,
Carl A. Lindstrom,
Michael Litos,
Kenneth A. Marsh,
Warren B. Mori,
Brendan O'Shea,
Navid Vafaei-Najafabadi,
Vitaly Yakimenko
Abstract:
Plasmas are a compelling medium for particle acceleration owing to their natural ability to sustain electric fields that are orders of magnitude larger than those available in conventional radio-frequency accelerators. Plasmas are also unique amongst accelerator technologies in that they respond differently to beams of opposite charge. The asymmetric response of a plasma to highly-relativistic ele…
▽ More
Plasmas are a compelling medium for particle acceleration owing to their natural ability to sustain electric fields that are orders of magnitude larger than those available in conventional radio-frequency accelerators. Plasmas are also unique amongst accelerator technologies in that they respond differently to beams of opposite charge. The asymmetric response of a plasma to highly-relativistic electron and positron beams arises from the fact that plasmas are composed of light, mobile electrons and heavy, stationary ions. Hollow channel plasma acceleration is a technique for symmetrizing the response of the plasma, such that it works equally well for high-energy electron and positron beams. In the experiment described here, we demonstrate the generation of a positron beam-driven wake in an extended, annular plasma channel, and acceleration of a second trailing witness positron bunch by the wake. The leading bunch excites the plasma wakefield and loses energy to the plasma, while the witness bunch experiences an accelerating field and gains energy, thus providing a proof-of-concept for hollow channel acceleration of positron beams. At a bunch separation of 330 um, the accelerating gradient is 70 MV/m, the transformer ratio is 0.55, and the energy transfer efficiency is 18% for a drive-to-witness beam charge ratio of 5:1.
△ Less
Submitted 30 December, 2023; v1 submitted 4 April, 2023;
originally announced April 2023.
-
High average gradient in a laser-gated multistage plasma wakefield accelerator
Authors:
Alexander Knetsch,
Igor A Andriyash,
Max Gilljohann,
Olena Kononenko,
Aimé Matheron,
Yuliia Mankovska,
Pablo San Miguel Claveria,
Viktoriia Zakharova,
Erik Adli,
Sébastien Corde
Abstract:
Plasma wakefield accelerators driven by particle beams are capable of providing accelerating gradient several orders of magnitude higher than currently used radio-frequency technology, which could reduce the length of particle accelerators, with drastic influence on the development of future colliders at TeV energies and the minimization of x-ray free-electron lasers. Since inter-plasma components…
▽ More
Plasma wakefield accelerators driven by particle beams are capable of providing accelerating gradient several orders of magnitude higher than currently used radio-frequency technology, which could reduce the length of particle accelerators, with drastic influence on the development of future colliders at TeV energies and the minimization of x-ray free-electron lasers. Since inter-plasma components and distances are among the biggest contributors to the total accelerator length, the design of staged plasma accelerators is one of the most important outstanding questions in order to render this technology instrumental. Here, we present a novel concept to optimize inter-plasma distances in a staged beam-driven plasma accelerator by drive-beam coupling in the temporal domain and gating the accelerator via a femtosecond ionization laser.
△ Less
Submitted 5 October, 2022;
originally announced October 2022.
-
Sharp dose profiles for high precision proton therapy using focused proton beams
Authors:
Fardous Reaz,
Kyrre Ness Sjobak,
Eirik Malinen,
Nina Frederike Jeppesen Edin,
Erik Adli
Abstract:
Proton beam therapy has been developed to irradiate the tumor with higher precision and dose conformity compared to conventional X-ray irradiation. The dose conformity of this treatment modality may be further improved if narrower proton beams are used. Still, this is limited by multiple Coulomb scattering of protons through tissue. The primary aim of this work was to develop techniques to produce…
▽ More
Proton beam therapy has been developed to irradiate the tumor with higher precision and dose conformity compared to conventional X-ray irradiation. The dose conformity of this treatment modality may be further improved if narrower proton beams are used. Still, this is limited by multiple Coulomb scattering of protons through tissue. The primary aim of this work was to develop techniques to produce narrow proton beams and investigate the resulting dose profiles. We introduced and assessed three different proton beam shaping techniques: 1) metal collimators (100/150~MeV), 2) focusing of conventional- (100/150~MeV), and 3) focusing of high-energy (350~MeV, shoot-through) proton beams. Focusing was governed by the initial value of the Twiss parameter $α$~($α_0$), and can be implemented with magnetic particle accelerator optics. The dose distributions in water were calculated by Monte Carlo simulations using Geant4, and evaluated by target to surface dose ratio (TSDR) in addition to the transverse beam size~($σ_T$) at the target. The target was defined as the location of the Bragg peak or the focal point. The different techniques showed greatly differing dose profiles, where focusing gave pronouncedly higher relative target dose and efficient use of primary protons. Metal collimators with radii < 2~mm gave low TSDRs (<~0.7) and large $σ_T$(>~3.6~mm). In contrast, a focused beam of conventional (150~MeV) energy produced a very high TSDR (>~80) with similar $σ_T$ as a collimated beam. High-energy focused beams were able to produce TSDRs > 100 and $σ_T$ around 1.5~mm. From this study, it appears very attractive to implement magnetically focused proton beams in radiotherapy of small lesions or tumors in close vicinity to healthy organs at risk. This can also lead to a paradigm change in spatially fractionated radiotherapy.
△ Less
Submitted 2 September, 2022;
originally announced September 2022.
-
Efficiency and beam quality for positron acceleration in loaded plasma wakefields
Authors:
C. S. Hue,
G. J. Cao,
I. A. Andriyash,
A. Knetsch,
M. J. Hogan,
E. Adli,
S. Gessner,
S. Corde
Abstract:
Accelerating particles to high energies in plasma wakefields is considered to be a promising technique with good energy efficiency and high gradient. While important progress has been made in plasma-based electron acceleration, positron acceleration in plasma has been scarcely studied and a fully self-consistent and optimal scenario has not yet been identified. For high energy physics applications…
▽ More
Accelerating particles to high energies in plasma wakefields is considered to be a promising technique with good energy efficiency and high gradient. While important progress has been made in plasma-based electron acceleration, positron acceleration in plasma has been scarcely studied and a fully self-consistent and optimal scenario has not yet been identified. For high energy physics applications where an electron-positron collider would be desired, the ability to accelerate positrons in plasma wakefields is however paramount. Here we show that the preservation of beam quality can be compromised in a plasma wakefield loaded with a positron beam, and a trade-off between energy efficiency and beam quality needs to be found. For electron beams driving linear plasma wakefields, we have found that despite the transversely nonlinear focusing force induced by positron beam loading, the bunch quickly evolves toward an equilibrium distribution with limited emittance growth. Particle-in-cell simulations show that for μm-scale normalized emittance, the growth of uncorrelated energy spread sets an important limit. Our results demonstrate that the linear or moderately nonlinear regimes with Gaussian drivers provide a good trade-off, achieving simultaneously energy-transfer efficiencies exceeding 30% and uncorrelated energy spread below 1%, while donut-shaped drivers in the nonlinear regime are more appropriate to accelerate high-charge bunches at higher gradients, at the cost of a degraded trade-off between efficiency and beam quality.
△ Less
Submitted 2 July, 2021;
originally announced July 2021.
-
Witness electron beam injection using an active plasma lens for a proton beam-driven plasma wakefield accelerator
Authors:
S. -Y. Kim,
K. Moon,
M. Chung,
K. N. Sjobak,
E. Adli,
S. Doebert,
M. Dayyani,
E. S. Yoon,
I. Nam,
G. Hahn
Abstract:
An active plasma lens focuses the beam in both the horizontal and vertical planes simultaneously using a magnetic field generated by a discharge current through the plasma. A beam size of 5--10 $μ$m can be achieved within a short distance using a focusing gradient on the order of 100 T/m. The active plasma lens is therefore an attractive element for plasma wakefield acceleration, because an ultra-…
▽ More
An active plasma lens focuses the beam in both the horizontal and vertical planes simultaneously using a magnetic field generated by a discharge current through the plasma. A beam size of 5--10 $μ$m can be achieved within a short distance using a focusing gradient on the order of 100 T/m. The active plasma lens is therefore an attractive element for plasma wakefield acceleration, because an ultra-small size of the witness electron beam is required for injection into the plasma wakefield to minimize emittance growth and to enhance the capturing efficiency. When the drive beam and witness electron beam co-propagate through the active plasma lens, interactions between the drive and witness beams, and the plasma must be considered. In this paper, through particle-in-cell simulations, we discuss the possibility of using an active plasma lens for the final focusing of the electron beam for the AWAKE RUN 2 experiments. It is confirmed that the amplitude of the plasma wakefield excited by proton bunches remains the same even after propagation through the active plasma lens. The emittance of the witness electron beam increases rapidly in the plasma density ramp regions of the lens. Nevertheless, when the witness electron beam has a charge of 100 pC, emittance of 10 mm mrad, and bunch length of 60 $μ$m, its emittance growth is not significant along the active plasma lens. For small emittance, such as 2 mm mrad, the emittance growth is found to be strongly dependent on the RMS beam size, plasma density, and multiple Coulomb scattering.
△ Less
Submitted 10 December, 2021; v1 submitted 20 April, 2021;
originally announced April 2021.
-
Multi-kT/m Focusing Gradient in a Linear Active Plasma Lens
Authors:
K. N. Sjobak,
E. Adli,
R. Corsini,
W. Farabolini,
G. Boyle,
C. A. Lindstrøm,
M. Meisel,
J. Osterhoff,
J. -H. Röckemann,
L. Schaper,
A. E. Dyson
Abstract:
Active plasma lenses are compact devices developed as a promising beam-focusing alternative for charged particle beams, capable of short focal lengths for high-energy beams. We have previously shown that linear magnetic fields with gradients of around 0.3 kT/m can be achieved in argon-filled plasma lenses that preserve beam emittance [C.A. Lindstrøm et al., Phys. Rev. Lett. 121, 194801 (2018)]. He…
▽ More
Active plasma lenses are compact devices developed as a promising beam-focusing alternative for charged particle beams, capable of short focal lengths for high-energy beams. We have previously shown that linear magnetic fields with gradients of around 0.3 kT/m can be achieved in argon-filled plasma lenses that preserve beam emittance [C.A. Lindstrøm et al., Phys. Rev. Lett. 121, 194801 (2018)]. Here we show that with argon in a 500 μm diameter capillary, the fields are still linear with a focusing gradient of 3.6 kT/m, which is an order of magnitude higher than the gradients of quadrupole magnets. The current pulses that generate the magnetic field are provided by compact Marx banks, and are highly repeatable. These results establish active plasma lenses as an ideal device for pulsed particle beam applications requiring very high focusing gradients that are uniform throughout the lens aperture.
△ Less
Submitted 19 December, 2020;
originally announced December 2020.
-
Experimental study of extended timescale dynamics of a plasma wakefield driven by a self-modulated proton bunch
Authors:
J. Chappell,
E. Adli,
R. Agnello,
M. Aladi,
Y. Andrebe,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
M. A. Baistrukov,
F. Batsch,
M. Bergamaschi,
P. Blanchard,
P. N. Burrows,
B. Buttenschön,
A. Caldwell,
E. Chevallay,
M. Chung,
D. A. Cooke,
H. Damerau,
C. Davut,
G. Demeter,
L. H. Deubner,
A. Dexter,
G. P. Djotyan,
S. Doebert
, et al. (74 additional authors not shown)
Abstract:
Plasma wakefield dynamics over timescales up to 800 ps, approximately 100 plasma periods, are studied experimentally at the Advanced Wakefield Experiment (AWAKE). The development of the longitudinal wakefield amplitude driven by a self-modulated proton bunch is measured using the external injection of witness electrons that sample the fields. In simulation, resonant excitation of the wakefield cau…
▽ More
Plasma wakefield dynamics over timescales up to 800 ps, approximately 100 plasma periods, are studied experimentally at the Advanced Wakefield Experiment (AWAKE). The development of the longitudinal wakefield amplitude driven by a self-modulated proton bunch is measured using the external injection of witness electrons that sample the fields. In simulation, resonant excitation of the wakefield causes plasma electron trajectory crossing, resulting in the development of a potential outside the plasma boundary as electrons are transversely ejected. Trends consistent with the presence of this potential are experimentally measured and their dependence on wakefield amplitude are studied via seed laser timing scans and electron injection delay scans.
△ Less
Submitted 12 October, 2020;
originally announced October 2020.
-
$γγ$ Beam-beam Parameter Study for a 3 TeV PWFA Linear Collider
Authors:
Jian Bin Ben Chen,
Daniel Schulte,
Erik Adli
Abstract:
Our beam-beam parameter study using beam-beam simulations and PWFA (particle-driven plasma acceleration) beam parameters indicates that at 3 TeV, for examined electron beam lengths ${2~μ\mathrm{m}\leqσ_z\leq 10~μ\mathrm{m}}$, the total luminosity, as well as the sharpness of the luminosity spectrum for a $γγ$ collider are independent of the beam length of the electron beams used to scatter the pho…
▽ More
Our beam-beam parameter study using beam-beam simulations and PWFA (particle-driven plasma acceleration) beam parameters indicates that at 3 TeV, for examined electron beam lengths ${2~μ\mathrm{m}\leqσ_z\leq 10~μ\mathrm{m}}$, the total luminosity, as well as the sharpness of the luminosity spectrum for a $γγ$ collider are independent of the beam length of the electron beams used to scatter the photons, given that the hourglass effect is avoided. The total luminosity can consequently be maximised by minimising the horizontal and vertical beta functions $β_{x,y}^*$ at the interaction point.
Furthermore, we performed background studies in GUINEA-PIG where we considered the smallest currently achievable $β_{x,y}^*$ combined with PWFA beam parameters. Simulations results show that our proposed parameter set for a 3 TeV PWFA $γγ$ collider is able to deliver a total luminosity significantly higher than a $γγ$ collider based on CLIC parameters, but gives rise to more background particles.
△ Less
Submitted 1 October, 2020;
originally announced October 2020.
-
$\mathrm{e}^+$$\mathrm{e}^-$ Beam-beam Parameter Study for a TeV-scale PWFA Linear Collider
Authors:
Jian Bin Ben Chen,
Daniel Schulte,
Erik Adli
Abstract:
We perform a beam-beam parameter study for a TeV-scale PWFA (particle-driven plasma wakefield acceleration) $\mathrm{e}^+$$\mathrm{e}^-$ linear collider using GUINEA-PIG simulations. The study shows that the total luminosity follows the $1/\sqrt{σ_z}$-scaling predicted by beamstrahlung theory, where $σ_z$ is the rms beam length, which is advantageous for PWFA, as short beam lengths are preferred.…
▽ More
We perform a beam-beam parameter study for a TeV-scale PWFA (particle-driven plasma wakefield acceleration) $\mathrm{e}^+$$\mathrm{e}^-$ linear collider using GUINEA-PIG simulations. The study shows that the total luminosity follows the $1/\sqrt{σ_z}$-scaling predicted by beamstrahlung theory, where $σ_z$ is the rms beam length, which is advantageous for PWFA, as short beam lengths are preferred. We also derive a parameter set for a 3 TeV PWFA linear collider with main beam parameters optimised for luminosity and luminosity spread introduced by beamstrahlung.
Lastly, the study also compare the performance for scenarios with reduced positron beam charge at 3 TeV and 14 TeV with CLIC parameters.
△ Less
Submitted 9 February, 2021; v1 submitted 28 September, 2020;
originally announced September 2020.
-
Proton beam defocusing in AWAKE: comparison of simulations and measurements
Authors:
A. A. Gorn,
M. Turner,
E. Adli,
R. Agnello,
M. Aladi,
Y. Andrebe,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
M. A. Baistrukov,
F. Batsch,
M. Bergamaschi,
P. Blanchard,
P. N. Burrows,
B. Buttenschon,
A. Caldwell,
J. Chappell,
E. Chevallay,
M. Chung,
D. A. Cooke,
H. Damerau,
C. Davut,
G. Demeter,
L. H. Deubner,
A. Dexter
, et al. (74 additional authors not shown)
Abstract:
In 2017, AWAKE demonstrated the seeded self-modulation (SSM) of a 400 GeV proton beam from the Super Proton Synchrotron (SPS) at CERN. The angular distribution of the protons deflected due to SSM is a quantitative measure of the process, which agrees with simulations by the two-dimensional (axisymmetric) particle-in-cell code LCODE. Agreement is achieved for beam populations between $10^{11}$ and…
▽ More
In 2017, AWAKE demonstrated the seeded self-modulation (SSM) of a 400 GeV proton beam from the Super Proton Synchrotron (SPS) at CERN. The angular distribution of the protons deflected due to SSM is a quantitative measure of the process, which agrees with simulations by the two-dimensional (axisymmetric) particle-in-cell code LCODE. Agreement is achieved for beam populations between $10^{11}$ and $3 \times 10^{11}$ particles, various plasma density gradients ($-20 ÷20\%$) and two plasma densities ($2\times 10^{14} \text{cm}^{-3}$ and $7 \times 10^{14} \text{cm}^{-3}$). The agreement is reached only in the case of a wide enough simulation box (at least five plasma wavelengths).
△ Less
Submitted 26 August, 2020;
originally announced August 2020.
-
Modeling and simulation of transverse wakefields in PWFA
Authors:
Jian Bin Ben Chen,
Daniel Schulte,
Erik Adli
Abstract:
A simplified model describing the PWFA (plasma wakefield acceleration) transverse instability in the form of a wake function parameterized only with an effective cavity aperture radius $a$ is benchmarked against PIC-simulations. This wake function implies a $1/a^4$ scaling of the transverse wakefields, which indicates transverse intra-beam wakefields typically several orders of magnitude higher th…
▽ More
A simplified model describing the PWFA (plasma wakefield acceleration) transverse instability in the form of a wake function parameterized only with an effective cavity aperture radius $a$ is benchmarked against PIC-simulations. This wake function implies a $1/a^4$ scaling of the transverse wakefields, which indicates transverse intra-beam wakefields typically several orders of magnitude higher than in conventional acceleration structures. Furthermore, the wakefield formalism is utilized to perform a parameter study for a \SI{1.5}{\tera\electronvolt} plasma wakefield accelerator, where the constraint on drive beam to main beam efficiency imposed by transverse wakefields is taken into account. Eventually, a parameter set with promising properties in terms of energy spread, stability and luminosity per power was found.
△ Less
Submitted 25 February, 2020; v1 submitted 19 December, 2019;
originally announced December 2019.
-
Electron bunch generation from a plasma photocathode
Authors:
Aihua Deng,
Oliver Karger,
Thomas Heinemann,
Alexander Knetsch,
Paul Scherkl,
Grace Gloria Manahan,
Andrew Beaton,
Daniel Ullmann,
Gregor Wittig,
Ahmad Fahim Habib,
Yunfeng Xi,
Mike Dennis Litos,
Brendan D. O'Shea,
Spencer Gessner,
Christine I. Clarke,
Selina Z. Green,
Carl Andreas Lindstrøm,
Erik Adli,
Rafal Zgadzaj,
Mike C. Downer,
Gerard Andonian,
Alex Murokh,
David Leslie Bruhwiler,
John R. Cary,
Mark J. Hogan
, et al. (3 additional authors not shown)
Abstract:
Plasma waves generated in the wake of intense, relativistic laser or particle beams can accelerate electron bunches to giga-electronvolt (GeV) energies in centimetre-scale distances. This allows the realization of compact accelerators having emerging applications, ranging from modern light sources such as the free-electron laser (FEL) to energy frontier lepton colliders. In a plasma wakefield acce…
▽ More
Plasma waves generated in the wake of intense, relativistic laser or particle beams can accelerate electron bunches to giga-electronvolt (GeV) energies in centimetre-scale distances. This allows the realization of compact accelerators having emerging applications, ranging from modern light sources such as the free-electron laser (FEL) to energy frontier lepton colliders. In a plasma wakefield accelerator, such multi-gigavolt-per-metre (GV m$^{-1}$) wakefields can accelerate witness electron bunches that are either externally injected or captured from the background plasma. Here we demonstrate optically triggered injection and acceleration of electron bunches, generated in a multi-component hydrogen and helium plasma employing a spatially aligned and synchronized laser pulse. This ''plasma photocathode'' decouples injection from wake excitation by liberating tunnel-ionized helium electrons directly inside the plasma cavity, where these cold electrons are then rapidly boosted to relativistic velocities. The injection regime can be accessed via optical density down-ramp injection, is highly tunable and paves the way to generation of electron beams with unprecedented low transverse emittance, high current and 6D-brightness. This experimental path opens numerous prospects for transformative plasma wakefield accelerator applications based on ultra-high brightness beams.
△ Less
Submitted 1 July, 2019;
originally announced July 2019.
-
Plasma Wakefield Linear Colliders - Opportunities and Challenges
Authors:
Erik Adli
Abstract:
A linear electron-positron collider operating at TeV scale energies will provide high precision measurements and allow, for example, precision studies of the Higgs boson as well as searches for physics beyond the standard model. A future linear collider should produce collisions at high energy, with high luminosity and with a good wall plug to beam power transfer efficiency. The luminosity per pow…
▽ More
A linear electron-positron collider operating at TeV scale energies will provide high precision measurements and allow, for example, precision studies of the Higgs boson as well as searches for physics beyond the standard model. A future linear collider should produce collisions at high energy, with high luminosity and with a good wall plug to beam power transfer efficiency. The luminosity per power consumed is a key metric that can be used to compare linear collider concepts. The plasma wakefield accelerator has demonstrated high-gradient, high-efficiency acceleration of an electron beam, and is therefore a promising technology for a future linear collider. We will go through the opportunities of using plasma wakefield acceleration technology for a collider, as well as a few of the collider-specific challenges that must be addressed in order for a high-energy, high luminosity-per-power plasma wakefield collider to become a reality.
△ Less
Submitted 6 May, 2019;
originally announced May 2019.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Experimental observation of proton bunch modulation in a plasma, at varying plasma densities
Authors:
E. Adli,
A. Ahuja,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
D. Barrientos,
M. M. Barros,
J. Batkiewicz,
F. Batsch,
J. Bauche,
V. K. Berglyd Olsen,
M. Bernardini,
B. Biskup,
A. Boccardi,
T. Bogey,
T. Bohl,
C. Bracco,
F. Braunmüller,
S. Burger,
G. Burt,
S. Bustamante,
B. Buttenschön,
A. Caldwell,
M. Cascella,
J. Chappell
, et al. (87 additional authors not shown)
Abstract:
We give direct experimental evidence for the observation of the full transverse self-modulation of a relativistic proton bunch propagating through a dense plasma. The bunch exits the plasma with a density modulation resulting from radial wakefield effects with a period reciprocal to the plasma frequency. We show that the modulation is seeded by using an intense laser pulse co-propagating with the…
▽ More
We give direct experimental evidence for the observation of the full transverse self-modulation of a relativistic proton bunch propagating through a dense plasma. The bunch exits the plasma with a density modulation resulting from radial wakefield effects with a period reciprocal to the plasma frequency. We show that the modulation is seeded by using an intense laser pulse co-propagating with the proton bunch which creates a relativistic ionization front within the bunch. We show by varying the plasma density over one order of magnitude that the modulation period scales with the expected dependence on the plasma density.
△ Less
Submitted 1 April, 2019; v1 submitted 12 September, 2018;
originally announced September 2018.
-
Acceleration of electrons in the plasma wakefield of a proton bunch
Authors:
The AWAKE Collaboration,
E. Adli,
A. Ahuja,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
D. Barrientos,
F. Batsch,
J. Bauche,
V. K. Berglyd Olsen,
M. Bernardini,
T. Bohl,
C. Bracco,
F. Braunmueller,
G. Burt,
B. Buttenschoen,
A. Caldwell,
M. Cascella,
J. Chappell,
E. Chevallay,
M. Chung,
D. Cooke,
H. Damerau,
L. Deacon,
L. H. Deubner
, et al. (69 additional authors not shown)
Abstract:
High energy particle accelerators have been crucial in providing a deeper understanding of fundamental particles and the forces that govern their interactions. In order to increase the energy or reduce the size of the accelerator, new acceleration schemes need to be developed. Plasma wakefield acceleration, in which the electrons in a plasma are excited, leading to strong electric fields, is one s…
▽ More
High energy particle accelerators have been crucial in providing a deeper understanding of fundamental particles and the forces that govern their interactions. In order to increase the energy or reduce the size of the accelerator, new acceleration schemes need to be developed. Plasma wakefield acceleration, in which the electrons in a plasma are excited, leading to strong electric fields, is one such promising novel acceleration technique. Pioneering experiments have shown that an intense laser pulse or electron bunch traversing a plasma, drives electric fields of 10s GV/m and above. These values are well beyond those achieved in conventional RF accelerators which are limited to ~0.1 GV/m. A limitation of laser pulses and electron bunches is their low stored energy, which motivates the use of multiple stages to reach very high energies. The use of proton bunches is compelling, as they have the potential to drive wakefields and accelerate electrons to high energy in a single accelerating stage. The long proton bunches currently available can be used, as they undergo self-modulation, a particle-plasma interaction which longitudinally splits the bunch into a series of high density microbunches, which then act resonantly to create large wakefields. The AWAKE experiment at CERN uses intense bunches of protons, each of energy 400 GeV, with a total bunch energy of 19 kJ, to drive a wakefield in a 10 m long plasma. Bunches of electrons are injected into the wakefield formed by the proton microbunches. This paper presents measurements of electrons accelerated up to 2 GeV at AWAKE. This constitutes the first demonstration of proton-driven plasma wakefield acceleration. The potential for this scheme to produce very high energy electron bunches in a single accelerating stage means that the results shown here are a significant step towards the development of future high energy particle accelerators.
△ Less
Submitted 11 October, 2018; v1 submitted 29 August, 2018;
originally announced August 2018.
-
Emittance Preservation in an Aberration-Free Active Plasma Lens
Authors:
C. A. Lindstrøm,
E. Adli,
G. Boyle,
R. Corsini,
A. E. Dyson,
W. Farabolini,
S. M. Hooker,
M. Meisel,
J. Osterhoff,
J. -H. Röckemann,
L. Schaper,
K. N. Sjobak
Abstract:
Active plasma lensing is a compact technology for strong focusing of charged particle beams, which has gained considerable interest for use in novel accelerator schemes. While providing kT/m focusing gradients, active plasma lenses can have aberrations caused by a radially nonuniform plasma temperature profile, leading to degradation of the beam quality. We present the first direct measurement of…
▽ More
Active plasma lensing is a compact technology for strong focusing of charged particle beams, which has gained considerable interest for use in novel accelerator schemes. While providing kT/m focusing gradients, active plasma lenses can have aberrations caused by a radially nonuniform plasma temperature profile, leading to degradation of the beam quality. We present the first direct measurement of this aberration, consistent with theory, and show that it can be fully suppressed by changing from a light gas species (helium) to a heavier gas species (argon). Based on this result, we demonstrate emittance preservation for an electron beam focused by an argon-filled active plasma lens.
△ Less
Submitted 23 November, 2018; v1 submitted 10 August, 2018;
originally announced August 2018.
-
Measurement of transverse wakefields induced by a misaligned positron bunch in a hollow channel plasma accelerator
Authors:
C. A. Lindstrøm,
E. Adli,
J. M. Allen,
W. An,
C. Beekman,
C. I. Clarke,
C. E. Clayton,
S. Corde,
A. Doche,
J. Frederico,
S. J. Gessner,
S. Z. Green,
M. J. Hogan,
C. Joshi,
M. Litos,
W. Lu,
K. A. Marsh,
W. B. Mori,
B. D. O'Shea,
N. Vafaei-Najafabadi,
V. Yakimenko
Abstract:
Hollow channel plasma wakefield acceleration is a proposed method to provide high acceleration gradients for electrons and positrons alike: a key to future lepton colliders. However, beams which are misaligned from the channel axis induce strong transverse wakefields, deflecting beams and reducing the collider luminosity. This undesirable consequence sets a tight constraint on the alignment accura…
▽ More
Hollow channel plasma wakefield acceleration is a proposed method to provide high acceleration gradients for electrons and positrons alike: a key to future lepton colliders. However, beams which are misaligned from the channel axis induce strong transverse wakefields, deflecting beams and reducing the collider luminosity. This undesirable consequence sets a tight constraint on the alignment accuracy of the beam propagating through the channel. Direct measurements of beam misalignment-induced transverse wakefields are therefore essential for designing mitigation strategies. We present the first quantitative measurements of transverse wakefields in a hollow plasma channel, induced by an off-axis 20 GeV positron bunch, and measured with another 20 GeV lower charge trailing positron probe bunch. The measurements are largely consistent with theory.
△ Less
Submitted 25 February, 2018;
originally announced February 2018.
-
Analytic plasma wakefield limits for active plasma lenses
Authors:
Carl A. Lindstrøm,
Erik Adli
Abstract:
Active plasma lensing is a promising technology for compact focusing of particle beams that has seen a recent surge of interest. While these lenses can provide strong focusing gradients of order kT/m and focusing in both transverse planes, there are limitations from nonlinear aberrations, causing emittance growth in the beams being focused. One cause of such aberrations is beam-driven plasma wakef…
▽ More
Active plasma lensing is a promising technology for compact focusing of particle beams that has seen a recent surge of interest. While these lenses can provide strong focusing gradients of order kT/m and focusing in both transverse planes, there are limitations from nonlinear aberrations, causing emittance growth in the beams being focused. One cause of such aberrations is beam-driven plasma wakefields, present if the beam density is sufficiently high. We develop simple, but powerful analytic formulas for the effective focusing gradient from these wakefields, and use this to set limits on which parts of the beam and plasma parameter space permits distortion-free use of active plasma lenses. It is concluded that the application of active plasma lenses to conventional and plasma-based linear colliders may prove very challenging, except perhaps in the final focus system, unless the typical discharge currents used are dramatically increased, and that in general these lenses are better suited for accelerator applications with lower beam intensities.
△ Less
Submitted 8 February, 2018;
originally announced February 2018.
-
Overview of the CLEAR plasma lens experiment
Authors:
C. A. Lindstrøm,
K. N. Sjobak,
E. Adli,
J. -H. Röckemann,
L. Schaper,
J. Osterhoff,
A. E. Dyson,
S. M. Hooker,
W. Farabolini,
D. Gamba,
R. Corsini
Abstract:
Discharge capillary-based active plasma lenses are a promising new technology for strongly focusing charged particle beams, especially when combined with novel high gradient acceleration methods. Still, many questions remain concerning such lenses, including their transverse field uniformity, limitations due to plasma wakefields and whether they can be combined in multi-lens lattices in a way to c…
▽ More
Discharge capillary-based active plasma lenses are a promising new technology for strongly focusing charged particle beams, especially when combined with novel high gradient acceleration methods. Still, many questions remain concerning such lenses, including their transverse field uniformity, limitations due to plasma wakefields and whether they can be combined in multi-lens lattices in a way to cancel chromaticity. These questions will be addressed in a new plasma lens experiment at the CLEAR User Facility at CERN. All the subsystems have been constructed, tested and integrated into the CLEAR beam line, and are ready for experiments starting late 2017.
△ Less
Submitted 8 February, 2018; v1 submitted 3 January, 2018;
originally announced January 2018.
-
Emittance preservation of an electron beam in a loaded quasi-linear plasma wakefield
Authors:
Veronica K. Berglyd Olsen,
Erik Adli,
Patric Muggli
Abstract:
We investigate beam loading and emittance preservation for a high-charge electron beam being accelerated in quasi-linear plasma wakefields driven by a short proton beam. The structure of the studied wakefields are similar to those of a long, modulated proton beam, such as the AWAKE proton driver. We show that by properly choosing the electron beam parameters and exploiting two well known effects,…
▽ More
We investigate beam loading and emittance preservation for a high-charge electron beam being accelerated in quasi-linear plasma wakefields driven by a short proton beam. The structure of the studied wakefields are similar to those of a long, modulated proton beam, such as the AWAKE proton driver. We show that by properly choosing the electron beam parameters and exploiting two well known effects, beam loading of the wakefield and full blow out of plasma electrons by the accelerated beam, the electron beam can gain large amounts of energy with a narrow final energy spread (%-level) and without significant emittance growth.
△ Less
Submitted 13 October, 2017;
originally announced October 2017.
-
AWAKE readiness for the study of the seeded self-modulation of a 400\,GeV proton bunch
Authors:
P. Muggli,
E. Adli,
R. Apsimon,
F. Asmus,
R. Baartman,
A. -M. Bachmann,
M. Barros Marin,
F. Batsch,
J. Bauche,
V. K. Berglyd Olsen,
M. Bernardini,
B. Biskup,
A. Boccardi,
T. Bogey,
T. Bohl,
C. Bracco,
F. Braunmuller,
S. Burger,
G. Burt,
S. Bustamante,
B. Buttenschon,
A. Butterworth,
A. Caldwell,
M. Cascella,
E. Chevallay
, et al. (82 additional authors not shown)
Abstract:
AWAKE is a proton-driven plasma wakefield acceleration experiment. % We show that the experimental setup briefly described here is ready for systematic study of the seeded self-modulation of the 400\,GeV proton bunch in the 10\,m-long rubidium plasma with density adjustable from 1 to 10$\times10^{14}$\,cm$^{-3}$. % We show that the short laser pulse used for ionization of the rubidium vapor propag…
▽ More
AWAKE is a proton-driven plasma wakefield acceleration experiment. % We show that the experimental setup briefly described here is ready for systematic study of the seeded self-modulation of the 400\,GeV proton bunch in the 10\,m-long rubidium plasma with density adjustable from 1 to 10$\times10^{14}$\,cm$^{-3}$. % We show that the short laser pulse used for ionization of the rubidium vapor propagates all the way along the column, suggesting full ionization of the vapor. % We show that ionization occurs along the proton bunch, at the laser time and that the plasma that follows affects the proton bunch. %
△ Less
Submitted 3 August, 2017;
originally announced August 2017.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
AWAKE, The Advanced Proton Driven Plasma Wakefield Acceleration Experiment at CERN
Authors:
E. Gschwendtner,
E. Adli,
L. Amorim,
R. Apsimon,
R. Assmann,
A. -M. Bachmann,
F. Batsch,
J. Bauche,
V. K. Berglyd Olsen,
M. Bernardini,
R. Bingham,
B. Biskup,
T. Bohl,
C. Bracco,
P. N. Burrows,
G. Burt,
B. Buttenschon,
A. Butterworth,
A. Caldwell,
M. Cascella,
E. Chevallay,
S. Cipiccia,
H. Damerau,
L. Deacon,
P. Dirksen
, et al. (66 additional authors not shown)
Abstract:
The Advanced Proton Driven Plasma Wakefield Acceleration Experiment (AWAKE) aims at studying plasma wakefield generation and electron acceleration driven by proton bunches. It is a proof-of-principle R&D experiment at CERN and the world's first proton driven plasma wakefield acceleration experiment. The AWAKE experiment will be installed in the former CNGS facility and uses the 400 GeV/c proton be…
▽ More
The Advanced Proton Driven Plasma Wakefield Acceleration Experiment (AWAKE) aims at studying plasma wakefield generation and electron acceleration driven by proton bunches. It is a proof-of-principle R&D experiment at CERN and the world's first proton driven plasma wakefield acceleration experiment. The AWAKE experiment will be installed in the former CNGS facility and uses the 400 GeV/c proton beam bunches from the SPS. The first experiments will focus on the self-modulation instability of the long (rms ~12 cm) proton bunch in the plasma. These experiments are planned for the end of 2016. Later, in 2017/2018, low energy (~15 MeV) electrons will be externally injected to sample the wakefields and be accelerated beyond 1 GeV. The main goals of the experiment will be summarized. A summary of the AWAKE design and construction status will be presented.
△ Less
Submitted 17 December, 2015;
originally announced December 2015.
-
Path to AWAKE: Evolution of the concept
Authors:
A. Caldwell,
E. Adli,
L. Amorim,
R. Apsimon,
T. Argyropoulos,
R. Assmann,
A. -M. Bachmann,
F. Batsch,
J. Bauche,
V. K. Berglyd Olsen,
M. Bernardini,
R. Bingham,
B. Biskup,
T. Bohl,
C. Bracco,
P. N. Burrows,
G. Burt,
B. Buttenschon,
A. Butterworth,
M. Cascella,
S. Chattopadhyay,
E. Chevallay,
S. Cipiccia,
H. Damerau,
L. Deacon
, et al. (96 additional authors not shown)
Abstract:
This report describes the conceptual steps in reaching the design of the AWAKE experiment currently under construction at CERN. We start with an introduction to plasma wakefield acceleration and the motivation for using proton drivers. We then describe the self-modulation instability --- a key to an early realization of the concept. This is then followed by the historical development of the experi…
▽ More
This report describes the conceptual steps in reaching the design of the AWAKE experiment currently under construction at CERN. We start with an introduction to plasma wakefield acceleration and the motivation for using proton drivers. We then describe the self-modulation instability --- a key to an early realization of the concept. This is then followed by the historical development of the experimental design, where the critical issues that arose and their solutions are described. We conclude with the design of the experiment as it is being realized at CERN and some words on the future outlook. A summary of the AWAKE design and construction status as presented in this conference is given in [1].
△ Less
Submitted 29 November, 2015;
originally announced November 2015.
-
9 GeV Energy Gain in a Beam-Driven Plasma Wakefield Accelerator
Authors:
M Litos,
E Adli,
J M Allen,
W An,
C I Clarke,
S Corde,
C E Clayton,
J Frederico,
S J Gessner,
S Z Green,
M J Hogan,
C Joshi,
W. Lu,
K A Marsh,
W B Mori,
M Schmeltz,
N Vafaei-Najafabadi,
V Yakimenko
Abstract:
An electron beam has gained a maximum energy of 9 GeV per particle in a 1.3 m-long electron beam-driven plasma wakefield accelerator. The amount of charge accelerated in the spectral peak was 28.3 pC, and the root-mean-square energy spread was 5.0%. The mean accelerated charge and energy gain per particle of the 215 shot data set was 115 pC and 5.3 GeV, respectively, corresponding to an accelerati…
▽ More
An electron beam has gained a maximum energy of 9 GeV per particle in a 1.3 m-long electron beam-driven plasma wakefield accelerator. The amount of charge accelerated in the spectral peak was 28.3 pC, and the root-mean-square energy spread was 5.0%. The mean accelerated charge and energy gain per particle of the 215 shot data set was 115 pC and 5.3 GeV, respectively, corresponding to an acceleration gradient of 4.0 GeV/m at the spectral peak. The mean energy spread of the data set was 5.1%. These results are consistent with the extrapolation of the previously reported energy gain results using a shorter, 36 cm-long plasma source to within 10%, evincing a non-evolving wake structure that can propagate distances of over a meter in length. Wake-loading effects were evident in the data through strong dependencies observed between various spectral properties and the amount of accelerated charge.
△ Less
Submitted 20 November, 2015;
originally announced November 2015.
-
Evidence for high-energy and low-emittance electron beams using ionization injection of charge in a plasma wakefield accelerator
Authors:
N. Vafaei-Najafabadi,
W. An,
C. E. Clayton,
C. Joshi,
K. A. Marsh,
W. B. Mori,
E. C. Welch,
W. Lu,
E. Adli,
J. Allen,
C. I. Clarke,
S. Corde,
J. Frederico,
S. J. Gessner,
S. Z. Green,
M. J. Hogan,
M. D. Litos,
V. Yakimenko
Abstract:
Ionization injection in a plasma wakefield accelerator was investigated experimentally using two lithium plasma sources of different lengths. The ionization of the helium gas, used to confine the lithium, injects electrons in the wake. After acceleration, these injected electrons were observed as a distinct group from the drive beam on the energy spectrometer. They typically have a charge of tens…
▽ More
Ionization injection in a plasma wakefield accelerator was investigated experimentally using two lithium plasma sources of different lengths. The ionization of the helium gas, used to confine the lithium, injects electrons in the wake. After acceleration, these injected electrons were observed as a distinct group from the drive beam on the energy spectrometer. They typically have a charge of tens of pC, an energy spread of a few GeV, and a maximum energy of up to 30 GeV. The emittance of this group of electrons can be many times smaller than the initial emittance of the drive beam. The energy scaling for the trapped charge from one plasma length to the other is consistent with the blowout theory of the plasma wakefield.
△ Less
Submitted 5 October, 2015;
originally announced October 2015.
-
A Beam Driven Plasma-Wakefield Linear Collider: From Higgs Factory to Multi-TeV
Authors:
Erik Adli,
Jean-Pierre Delahaye,
Spencer J. Gessner,
Mark J. Hogan,
Tor Raubenheimer,
Weiming An,
Chan Joshi,
Warren Mori
Abstract:
Plasma wakefield acceleration (PWFA) holds much promise for advancing the energy frontier because it can potentially provide a 1000-fold or more increase in acceleration gradient with excellent power efficiency in respect with standard technologies. Most of the advances in beam-driven plasma wakefield acceleration were obtained by a UCLA/USC/SLAC collaboration working at the SLAC FFTB[ ]. These ex…
▽ More
Plasma wakefield acceleration (PWFA) holds much promise for advancing the energy frontier because it can potentially provide a 1000-fold or more increase in acceleration gradient with excellent power efficiency in respect with standard technologies. Most of the advances in beam-driven plasma wakefield acceleration were obtained by a UCLA/USC/SLAC collaboration working at the SLAC FFTB[ ]. These experiments have shown that plasmas can accelerate and focus both electron and positron high energy beams, and an accelerating gradient in excess of 50 GeV/m can be sustained in an 85 cm-long plasma. The FFTB experiments were essentially proof-of-principle experiments that showed the great potential of plasma accelerators.
The FACET[ ] test facility at SLAC will in the period 2012-2016 further study several issues that are directly related to the applicability of PWFA to a high-energy collider, in particular two-beam acceleration where the witness beam experiences high beam loading (required for high efficiency), small energy spread and small emittance dilution (required to achieve luminosity).
The PWFA-LC concept presented in this document is an attempt to find the best design that takes advantage of the PWFA, identify the critical parameters to be achieved and eventually the necessary R&D to address their feasibility. It best benefits from the extensive R&D that has been performed for conventional rf linear colliders during the last twenty years, especially ILC[ ] and CLIC[ ], with a potential for a comparably lower power consumption and cost.
△ Less
Submitted 29 September, 2013; v1 submitted 5 August, 2013;
originally announced August 2013.